Contact Us

TPS53219ARGTR

Brand: Texas Instruments
Texas Instruments TPS53219ARGTR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS53219ARGTR — Power Management & Signal Chain | Superb Automation

TPS53219ARGTR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS53219ARGTR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS53219ARGTR: 3 V to 28 V D-CAP synchronous buck controller

TPS53219ARGTR is a single phase adaptive on time buck controller without a compensation network in a QFN body of 16 pins. It drives two external FETs for a rail from 0.6 V to 5.5 V at more than 20 A, and it senses current through the low side FET instead of a shunt.

Order code and package

Order codeTPS53219ARGTR, RGT package, 3000 pieces on a reel
BodyQFN, 3.00 mm by 3.00 mm, sixteen pins plus the thermal pad
Reference0.6 V with 0.8 per cent accuracy
FrequencyEight settings selected by the RF pin, 300 kHz to 1070 kHz typical
Soft start0.7 ms, 1.4 ms, 2.8 ms or 5.6 ms selected by the MODE pin

Electrical parameters that decide the application

Conversion input3 V to 28 V at the high side drain, 4.5 V to 25 V on the VDD pin
Output range0.6 V to 5.5 V, 0 A to more than 20 A
Current senseLow side RDS(on), with the TRIP pin sourcing 10 uA at 4700 ppm per C
Current limitVOCL equals VTRIP divided by 8, with VTRIP capped at 3 V
Negative limitAbout 200 mV at the SW node in the reverse direction
Light loadAuto skip Eco-Mode, entered and left on load current without a mode pin
Transient100 ns load step response claimed for the D-CAP loop
Vendor temperature-40 C to +85 C, which is narrower than the converters in this band

Family variants and how they differ

RF pinOne resistor sets one of eight frequencies from 300 kHz to 1070 kHz
MODE pinSets the 0.7 ms, 1.4 ms, 2.8 ms or 5.6 ms soft start ramp
LDOBuilt in regulator for the driver supply, no external 5 V rail needed
TRIP pinCurrent limit through the low side FET, the same scheme as the TPS51215A
Boost switchIntegrated, so the bootstrap capacitor is the only external part for the high side driver

Points to check before this part goes on a BOM

Sensing current through the low side FET removes a shunt but moves the accuracy problem. A 2 mOhm FET with a 20 per cent tolerance gives a limit that is 20 per cent off before temperature, and the 4700 ppm per C coefficient on the TRIP current only compensates the drift, not the spread. A rail that has to survive a hard short needs the limit set low enough that the worst case FET is still safe.

The current limit arithmetic is short. VOCL is VTRIP divided by 8, so a 1.6 V TRIP node gives a 200 mV sense threshold, and across a 1 mOhm low side FET that is 200 A. The 3 V cap means the largest sense voltage is 375 mV, so the controller stops limiting long before the FET does, and the inductor saturation current is the real ceiling.

The 3 V to 28 V conversion input is wider than the 4.5 V to 25 V VDD pin, which is a trap for a 5 V only board. The controller needs the bias rail up before it can drive anything, and the internal LDO covers that from VDD, so a 3.3 V input rail that has to produce 1.2 V still needs a way to get VDD above 4.5 V.

The -40 C to +85 C rating is the honest number and it is narrower than the converters alongside it in this band. A rail in a sealed enclosure at 70 C ambient with 2 W of controller and driver loss is already at the limit, and the 20 A figure assumes the FETs, not the controller, carry the current.

Eco-Mode with auto skip is the right light load behaviour for a rail that spends most of its life at a few milliamps, but the loop leaves the fixed frequency state and the output ripple grows. A load that cannot tolerate more than 20 mV of ripple should not use skip mode, and this part has no pin to disable it.

The 0.7 ms soft start option is short for a large output bank. Charging 1000 uF to 1.2 V in 0.7 ms needs 1.7 A of capacitor current on top of the load, and a 20 A rail will do it, but a 5 A rail will hit the current limit and hiccup. The MODE pin has a 5.6 ms option for exactly that case.

Pre-charged start up matters when a rail is sequenced behind another one. The controller holds off until the internal ramp passes the output voltage, so the low side FET does not discharge the rail and the inrush is only what the load needs, not what a discharged bank would take.

The eight frequency settings are deliberately coarse, because the loop is on time based. Changing from 300 kHz to 1070 kHz changes the on time by a factor of three and with it the minimum controllable duty, so a 28 V to 0.6 V conversion belongs at the low end and a small, fast transient rail at the high end.

The internal LDO that feeds the drivers drops the difference between VDD and the driver rail, and at 28 V that difference is more than 20 V. A few milliamps of driver current becomes tens of milliwatts inside a 3 mm body, which is a real part of the 85 C ambient limit and the reason this controller is happiest on a 12 V or 19 V bias.

The 100 ns load step response belongs to the loop, not to the power stage. A 20 A step delivered in 100 ns needs output capacitance with a low enough impedance at 1 MHz to hold the rail, so the capacitors and the controller have to be chosen together. A rail with 10 uF of ceramic will meet the controller and miss the transient by a hundred millivolts.

Power good is open drain and has its own window against the reference, so it asserts only after the rail is inside a band that is tighter than the regulation limit. A supervisor that uses PGOOD to release a reset gets a rail that is genuinely up, and one that uses a resistor divider on the rail gets a reset release that varies with the divider tolerance and the load.

Where this order code fits

The part suits a point of load rail in a storage or server board, an embedded computer or a printer, where several amps come from a 12 V or 19 V intermediate bus and the board has no room for a compensation network. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the BOM Shortage Recovery page.

Questions buyers ask

Can it drive FETs rated for more than 20 A? The controller does not limit the current, the FETs and the inductor do. The 20 A figure is the load range the loop is characterised over.

Does it need an external 5 V rail? No, the internal LDO makes the driver supply from VDD, which must be between 4.5 V and 25 V.

What sets the current limit? The TRIP resistor, which sets a sense voltage across the low side FET. There is no shunt resistor in the path.

Is 85 C enough for an industrial board? Only with a thermal calculation behind it. The junction has to stay under 125 C, and the controller dissipates its own driver loss plus the LDO drop.

Does the controller need a separate bias supply? The internal LDO makes the driver rail from VDD, so only VDD has to be present. VDD must be between 4.5 V and 25 V even when the conversion input is 3 V.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Pin to Pin Cross Reference page sets out the checks that keep a substitute from failing on the bench.