TPS53127RGER
Product Specifications
TPS53127RGER
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS53127RGER from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS53127 dual D-CAP2 controller for low voltage rails with no loop compensation
The TPS53127RGER is a dual synchronous buck controller that runs both stages from adaptive on time D-CAP2 control, which means the loop is stable without any external compensation network. It takes an input from 4.5 V to 24 V, produces two outputs anywhere from 0.76 V to 5.5 V, and switches at a fixed 700 kHz. The two stages are independent, so one board can carry a 3.3 V housekeeping rail and a 1.2 V core rail from the same part.
The D-CAP2 loop is what removes the compensation components, and the same circuit works with POSCAP and SP-CAP output capacitors as well as with all ceramic banks. That matters on a board where the two rails have different capacitor types, because a single controller family that handles both saves a second qualification and a second set of loop measurements.
Key parameters taken from the SLVSA93A document
| Input range | 4.5 V to 24 V, which covers a 5 V, 12 V or 19 V adapter rail and a 24 V industrial bus at its top end |
| Output range | 0.76 V to 5.5 V on each stage, set by the feedback divider |
| Reference accuracy | 1 % initial, so the divider and the reference together set the tolerance at the load |
| Switching frequency | 700 kHz fixed, the same on both stages |
| Current sensing | Low side RDS(on) sensing, lossless, so no shunt in either power path |
| Overcurrent threshold | Programmable from 30 mV to 300 mV at the ITRIP pin, with thermal compensation of 4000 ppm per degree |
| Gate drive | Adaptive drivers with an integrated bootstrap diode, so no external bootstrap diode on either stage |
| Soft start | Adjustable, and non sinking on a prebiased output, so an already charged rail is not pulled down |
| Protection | Cycle by cycle overcurrent limiting, and the pair of stages can be sequenced by the enable pins |
| Package | 24 pin RGE or PW body, minus 40 to plus 85 degrees ambient |
What the 4000 ppm per degree compensation does for the current limit
The overcurrent comparator measures the voltage across the low side FET while it conducts, and that voltage rises with temperature because the FET resistance rises. Without compensation the limit would fall as the board heats up, and a converter rated at 6 A cold would trip at 4 A hot. The 4000 ppm per degree term is the temperature coefficient applied to the ITRIP threshold, which tracks the FET resistance and keeps the trip point close to constant over the operating range.
It is an approximation, because the coefficient of the internal reference is fixed while the coefficient of the FET depends on the device. A board that uses a FET with a different temperature coefficient than the one the compensation assumes ends up with a limit that drifts one way or the other, and the 30 mV to 300 mV window is wide enough that a 20 % drift still leaves a usable setting.
Where the TPS53127 belongs on the board
- Point of load rails in instruments that need a 3.3 V analog rail and a 1.8 V digital rail from a 12 V feed
- Industrial controllers with a 24 V bus that need two low voltage rails and no compensation components
- Networking equipment where the two rails carry different capacitor types, one polymer and one ceramic
- Boards that must start into a prebiased load, such as an FPGA whose core is charged through its own path
- Retrofit boards where the compensation network of an older controller has to be removed to save area
Order code, package and thermal limits
| TPS53127RGER | 24 pin RGE QFN, large reel |
| TPS53127PW | The same silicon in the PW TSSOP body, for boards that cannot use a QFN |
| Ambient | Minus 40 to plus 85 degrees, with the junction limit higher, so the thermal path through the pad is what sets the usable current |
| Gate drive level | Set by the bias rail derived from the input, so a 24 V input needs FETs rated for that gate drive |
Sourcing notes for this line
Dual controllers in a 24 pin body are a mature part, and the supply risk is the specific order code rather than the silicon. The comparison table to work from is the power management cross reference, which lists the dual controllers that share the RGE footprint and points out the ones with a different current sense scheme.
Where the exact code is short, the two levers are the package, since the PW body is the same silicon, and the current limit scheme, since a part with a fixed limit needs the FET checked against the load. The pin to pin cross reference page sets out which substitutions keep the footprint.
For a build that is short on both stages, splitting into two single controllers is the usual fallback, and the BOM shortage recovery page describes the rework that goes with it.
Questions buyers ask about this part
Does it really need no compensation components? Correct, on both stages. The D-CAP2 loop is internally compensated, which is why the external component count on this part is limited to the FETs, the inductors, the output capacitors and the feedback dividers.
Can both stages run at different output voltages? Yes. Each stage has its own feedback divider and its own enable, so 5 V and 1.2 V from the same part is a normal configuration.
What happens with a ceramic output bank? The loop is specified to work with all ceramic capacitors as well as with polymer parts, which is the main reason the D-CAP2 topology exists.
Is the current limit accurate enough to skip a fuse? No. The RDS(on) sensing with a 4000 ppm per degree compensation keeps the trip point in a usable band, but it is a protection function, not a precision measurement.