Contact Us

TPS43351QDAPRQ1

Brand: Texas Instruments
Texas Instruments TPS43351QDAPRQ1 is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS43351QDAPRQ1 — Power Management & Signal Chain | Superb Automation

TPS43351QDAPRQ1

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS43351QDAPRQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS43351QDAPRQ1: dual synchronous buck controller for multi rail automotive boards

TPS43351QDAPRQ1 is two current mode synchronous buck controllers in one body in a HTSSOP body of 38 pins. Two independent buck channels with external FETs, a 40 V input that survives 60 V transients, and a low power mode that draws 30 uA with one channel running. Each output goes from 0.9 V to 11 V, the two channels switch out of phase, and the frequency is set between 150 kHz and 600 kHz.

Order code and package

TPS43351QDAPRQ1active, production, HTSSOP 38 pins, 2000 pieces on a large reel
Lead finishNIPDAU, RoHS Yes
Moisture levelLevel 3, 260 C, 168 hour floor life
MarkingTPS43351Q1
Temperatureminus 40 to 125 C ambient, AEC-Q100 grade 1
Body12.50 mm by 6.20 mm with a PowerPAD on the underside

Electrical parameters that decide the application

Input voltageup to 40 V operating, 60 V transients
Output voltage0.9 V to 11 V on each channel
Low power mode30 uA with one channel on, 35 uA with both
Shutdown currentunder 4 uA
Switching frequency150 kHz to 600 kHz, programmable and synchronisable
Gate drive1.5 A peak
Current sensesense resistor or inductor DCR
Phase relationshipthe two channels switch out of phase
Soft startseparate pins for each channel
Spread spectrumon the TPS43351 only, not on the TPS43350

Family variants and how they differ

TPS43350-Q1same body without frequency spread spectrum
TPS43351-Q1adds spread spectrum for emissions, the member on this page
Light loadforced continuous or automatic low power mode, pin selectable
Enableseparate ENA and ENB pins
Current limitcycle by cycle with frequency foldback on a short circuit
Reference0.8 V per channel, set by external dividers

Points to check before this part goes on a BOM

These are controllers, not converters. The current capability belongs to the external FETs, and the 1.5 A gate drive sets the ceiling on the gate charge that can be switched at 600 kHz. A pair of 30 A FETs with 60 nC of gate charge will not reach 600 kHz on this driver.

Inductor DCR sensing removes the shunt and its loss, and it drifts with copper temperature. A build that uses DCR sensing to save 10 mV of drop has to accept a current limit that moves with temperature unless the network is compensated with an NTC or a resistor pair matched to copper.

Out of phase switching halves the ripple the input capacitor sees, which is the reason a single input capacitor can serve both channels. It does not halve the total input current, so the capacitor RMS rating is still set by the sum of the two channel currents.

The 30 uA low power mode is the figure that matters in a parked vehicle. With one channel running at 30 uA the standby drain on a 60 Ah battery is under 0.3 Ah per year from the controller alone, and the feedback dividers usually draw more than that.

Spread spectrum is the only electrical difference between the 43350 and the 43351. For a module that has to pass a CISPR 25 scan near the band edges, the dithering moves the peak energy and can be the difference between a pass and a filter that has to be rebuilt.

The 60 V transient rating is not a load dump rating. A load dump can reach far higher for a longer time and needs a suppressor; the 60 V figure covers the switching transients on a 24 V rail with the alternator running.

Moisture level 3 with 168 hours applies here as well. A 38 pin PowerPAD body also needs the pad soldered to a copper area with vias, because the gate drive losses and the regulator losses both land there.

Two rails, one input

A typical automotive build takes the battery rail down to 3.3 V on one channel and 5 V on the other, with the 5 V channel feeding CAN transceivers and the 3.3 V channel feeding the microcontroller. Both outputs are set by dividers from the same 0.8 V reference, so the two rails track each other within the reference tolerance.

Because the channels switch out of phase, the input capacitor sees a ripple at twice the channel frequency with a lower amplitude than either channel alone. That is the main reason to use a dual controller instead of two single ones in the same footprint.

Where the margin sits

The 40 V input rating against a 24 V rail leaves 40 per cent of margin, which is adequate for a regulated bus and not for a battery line. On a battery line the suppressor and the reverse battery FET are what keep the controller inside its window.

The gate drive current, the FET gate charge and the frequency form one budget. Doubling the frequency halves the inductor and doubles the drive loss, and the thermal pad is where that loss ends up.

The two channels also share the 40 V input rating, so one suppressor protects both. Where the two rails come from a common battery feed and one channel is loaded by a motor, the suppressor sees the combined transient and has to be sized for it rather than for a single converter.

Loss split between the two channels

The gate drive loss belongs to the controller but the heat lands in the FETs and the pad under them. At 600 kHz with 40 nC of gate charge on four FETs, the driver delivers about 100 mW of gate energy, and the switching loss in the FETs themselves is several times that.

That is why the two channels are usually built with different FETs. The 5 V channel that feeds a transceiver can use a small die with low gate charge, while the 3.3 V channel that carries the processor current uses a larger one, and the controller drives both from the same 1.5 A driver without either channel setting the frequency limit.

The two channels also share one input capacitor, so the loss question is not only thermal. A capacitor that is adequate for the average current of both channels will still see the sum of the two ripple currents, and the ripple current rating falls with temperature. Running the capacitor at half its rating at 25 C is the usual margin for a module that has to survive a hot soak in a dashboard.

Where this order code fits

The order code is used in infotainment head units, clusters and body controllers that need two rails from one battery input with a low standby drain. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Pin to Pin Cross Reference page.

Questions buyers ask

Can one channel be shut down independently? Yes. ENA and ENB are separate pins and each channel has its own soft start. The other channel keeps running and the low power mode current changes from 35 uA to 30 uA.

What is the maximum output current? There is no number in the datasheet, because the current flows through external FETs. The practical ceiling is set by the gate charge the driver can switch and by the thermal path under the FETs.

Is spread spectrum always on? On the TPS43351 it is enabled by a pin strap, so a build that needs a fixed frequency for synchronisation can turn it off.

Does it need a sense resistor? Not necessarily. The current can be sensed across the inductor DCR, which removes the shunt loss, at the cost of a limit that tracks copper temperature.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the How to Verify a Drop in Replacement page sets out the checks that keep a substitute from failing on the bench.