TPS3840PL43DBVR
Product Specifications
TPS3840PL43DBVR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS3840PL43DBVR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS3840PL43DBVR 4.3 V supervisor for a 5 V rail with 200 mV of hysteresis
The TPS3840PL43DBVR is the 4.3 V member of the TPS3840 family, a push-pull active-low supervisor in the 5 pin SOT-23 that watches a rail against a fixed 4.3 V falling threshold. It is built for a 5 V rail that has to be protected from a slow collapse rather than from a fast transient, and the 4.3 V trip leaves 0.7 V of margin against the 5 V nominal, which covers a 5 % supply and the threshold window with room left for a series diode.
The distinguishing number on this member is the hysteresis. Above a 3.1 V threshold the family specifies 200 mV typical instead of 100 mV, so the release point is 4.5 V. On a 5 V rail that is 10 % of the rail, and it is the reason the part does not oscillate when a load switch or a relay coil pulls the rail down and lets it recover.
Key parameters taken from the SNVSB03E document
| Supply range | 1.5 V to 10 V on VDD, so a 5 V rail is inside the range with 5 V of headroom above it |
| Falling threshold | 4.3 V nominal, 1 % typical and 1.5 % maximum, which is plus or minus 64.5 mV at the extremes |
| Hysteresis | 200 mV typical for thresholds between 3.1 V and 4.9 V, printed as a 175 to 225 mV window |
| Release point | 4.5 V nominal, so the rail has to recover 200 mV before the reset delay starts |
| Supply current | 300 nA typical and 700 nA maximum, unchanged from the low voltage members of the family |
| Output | Push-pull active-low, 0.8 times VDD minimum high at 2 mA source, 200 mV maximum low at 2 mA sink |
| Start-up delay | 220 microseconds typical, 350 microseconds maximum with CT open |
| Reset delay | 50 microseconds with CT open up to 6.2 s at 10 microfarad |
| Propagation | 15 microseconds typical and 30 microseconds maximum from the trip point |
| Glitch immunity | 10 microseconds at 5 % overdrive, which on this member is a 215 mV dip before the output moves |
| Manual reset | MR pin, 600 mV maximum low, 0.7 times VDD minimum high, internal 100 kOhm pull-up |
| Power-on reset | Output defined from 300 mV of VDD on the push-pull output |
| Temperature | Minus 40 to plus 125 degrees junction, the full industrial range |
Watching a 5 V rail without a divider
Because the input range reaches 10 V, a 5 V rail connects to VDD with no divider, which removes two resistors and the error they would add. The same is true of a 9 V battery, and the part is often used on a 5 V intermediate rail in equipment that runs from 12 V or 24 V, where the 5 V rail is the one that has to reach the digital section before the rest of the board is released.
The margin analysis is short. A 5 V rail at minus 5 % is 4.75 V and the worst case trip is 4.2355 V, so the gap is 515 mV. A 5 V rail at minus 10 % is 4.5 V, and the release point is also 4.5 V, which means a rail sitting exactly at minus 10 % hovers at the hysteresis edge. A supply that is allowed to run at minus 10 % is a supply that needs a 4.0 V member, not this one.
The 200 mV hysteresis is the second half of that analysis. After a fault the rail must pass 4.5 V before the delay begins, and on a supply with a small reservoir the recharge time is part of the recovery. A customer who measures a longer reset than the capacitor suggests is usually seeing the hysteresis plus the ramp, not a slow capacitor.
Delay, glitch and the MR pin
The delay chain is the same as every other member of the family, which is what makes the part easy to drop into a board that already uses the 2.5 V version.
| CT open | 50 microseconds, used where the reset only has to be a defined pulse |
| CT 10 nF | 6.2 ms, the usual setting for a logic section that has no clock of its own |
| CT 1 microfarad | 619 ms, the setting for a rail that feeds a motor driver or a relay bank |
| CT 10 microfarad | 6.2 s, the ceiling, and only with a low leakage ceramic part |
| Glitch window | 10 microseconds at 5 % overdrive means a 215 mV dip shorter than that is ignored entirely |
The glitch immunity on this member is worth noting against a relay or a solenoid load. A 215 mV dip that lasts less than 10 microseconds is the shape of a switching transient, and the part is specified to ignore it. A dip that lasts longer than the propagation delay is a real fault and the output moves within 30 microseconds.
The MR pin runs on the same 5 V rail with a 600 mV low threshold, so a front panel button can pull it low through a series resistor and the internal 100 kOhm pull-up restores it. There is 10 microseconds of glitch immunity on that pin too, which is enough to reject contact bounce on a good switch and not enough on a worn one, so a 100 nF capacitor across the switch is a common addition that costs nothing in a 5 V system.
Where the PL43 belongs
- 5 V digital rails in equipment that also carries 12 V or 24 V, where the 5 V rail has to be valid before the loads are enabled
- Relay, solenoid and motor driver boards where the rail dips on every switching event and a 100 mV hysteresis would chatter
- Building automation panels and fire detection equipment that run from a 5 V backplane
- 9 V battery products that need a defined cut-off at 4.3 V rather than a slow brownout
Order code, marking and reel
| TPS3840PL43DBVR | Active, production, SOT-23 DBV 5 pin, 3000 pieces on a large reel |
| Lead finish | NIPDAU, moisture level 1 at 260 degrees, unlimited floor life |
| Part marking | PL42 on the body, one code below the 4.3 V option, so the marking alone will not confirm the threshold |
| Siblings | TPS3840DL43DBVR open-drain and TPS3840PH43 active-high, same body and pinout |
| Higher rails | No member of the family goes above 10 V on the input, so a 12 V or 24 V rail needs a divider on any of them |
An incoming check that reads the marking will find PL42 on a reel of PL43. The two are the same threshold option, and the marking table in the addendum lists one code below the option number right across the family, so this is consistent behaviour rather than a mixed reel.
Sourcing notes for this line
A 4.3 V supervisor is a narrower requirement than a 2.5 V one, and the parts that claim to replace it often differ in the two numbers that matter here, the hysteresis and the input ceiling. The power management cross reference lists the candidates by pinout and marks the ones whose hysteresis is 100 mV rather than 200 mV.
Where a 5 V rail has to be watched and the exact code is not available, a part with a 4.2 V or 4.4 V threshold and the same 200 mV hysteresis is the honest alternate, because it moves the trip by 100 mV and leaves the release behaviour intact. That comparison is what the pin to pin cross reference page is built for, and the trip point should be measured on the first article rather than assumed from the datasheet heading.
Long life programmes for building automation and metering usually keep a second source alive even when the primary is available, because these boards stay in production for a decade. The last time buy and long life planning page sets out how that buffer is sized against the vendor lifecycle status.
Questions buyers ask about this part
Can it watch a 12 V rail? Only through a divider. The input stops at 10 V, and above that the part is outside its ratings even though the threshold is far below the rail.
Why does my reset last longer than the capacitor says? Because the delay starts when the rail passes 4.5 V, not when the fault clears. Add the recharge time of the supply to the capacitor figure.
Does the 200 mV hysteresis apply at 4.3 V exactly? Yes. The 175 to 225 mV window belongs to every threshold from 3.1 V to 4.9 V, and the 100 mV window belongs to 1.6 V through 3.0 V.
Can two of these supervise a 5 V and a 3.3 V rail in sequence? Yes, and the usual arrangement is the 5 V member driving the enable of the 3.3 V regulator, so the second supervisor only starts after the first has released.