TPS281C30ARGWR
Product Specifications
TPS281C30ARGWR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS281C30ARGWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS281C30ARGWR 60 V tolerant 30 milliohm smart high side switch
The TPS281C30ARGWR is a single channel smart high side switch in a 20 pin 5 mm by 5 mm QFN, made for industrial output channels that switch a 24 V field load. It tolerates 60 V, works from 6 V to 36 V, holds 64 V when disabled, and switches through a 30 milliohm typical, 55 milliohm maximum pass FET. The A on the end of the string sets the current limit window at 1 A to 5 A with a fixed 0.5 A step.
Around that switch the part carries what an industrial output normally needs in discrete form: an adjustable current limit, a current sense output with two accuracy modes, an inductive discharge clamp above 65 V, open load detection in the off state, thermal shutdown and a fault output. The E version adds an enhanced fast transient immunity claim, and the document prints the test conditions for it, which is unusual enough to be worth reading before a compliance claim is repeated.
Key parameters taken from the TPS281C30 document
| Channels | One |
| Operating voltage | 6 V to 36 V, with 64 V DC tolerance while disabled |
| On resistance | 30 milliohm typical, 55 milliohm maximum |
| Steady load | Up to 6 A DC in the reference conditions |
| Current limit, A and C | 1 A to 5 A, set in 0.5 A steps |
| Current limit, B, D and E | 2 A to 10 A, set in 0.5 A steps |
| Current sense accuracy | 4 per cent at 1 A in the standard mode, 12.5 per cent at 6 mA in the high accuracy mode |
| Inductive clamp | Integrated, above 65 V |
| Standby current | Below 1 microamp in standby, on versions A, B, C and D |
| Quiescent current | Below 1.5 milliamp |
| Logic levels | Inputs compatible with 1.8 V, 3.3 V and 5 V control |
| Diagnostics | Open load detection in the off state, fault sense output scaled for an ADC |
| Protection | Thermal shutdown, swing detection, adjustable current limit |
| Temperature | Minus 40 to plus 125 degrees junction |
| Package | QFN RGW, 20 pins, 5 mm by 5 mm, 0.65 mm pitch; a 14 pin HTSSOP is offered on other versions |
| Functional safety | Listed as functional safety capable in the document |
The document pairs this table with a set of conditions, and the current sense accuracy in particular depends on the mode selected. The 12.5 per cent figure at 6 mA is a low current mode, not an error to be compared against the 4 per cent figure at 1 A.
Where the numbers matter in a real build
The 64 V DC tolerance while disabled is the number that keeps an industrial output alive during an inductive kick on the shared field supply. A contactor coil on the same 24 V bus as the switch can pull the rail well above its nominal value when it opens, and a part rated only to the working voltage would need a clamp in front of it. Here the clamp is inside, above 65 V, so the external part count drops.
Thirty milliohm at 5 A is 750 milliwatt inside a 5 mm package, which is the thermal limit that decides how many channels can be on at once in a sealed enclosure. The max figure of 55 milliohm is what a worst case calculation should use, and at 6 A that is nearly 2 W, so the thermal information section and the copper under the pad are part of the specification rather than an afterthought.
The two sense modes are the third point. Standard mode gives 4 per cent at 1 A and suits a trip decision or a load current display. High accuracy mode reaches down to 6 mA with 12.5 per cent, which is what a broken wire or a lamp filament check needs, since those events show as a small current rather than a large one. Selecting the mode is a register choice, so the same reel can serve both jobs.
- The version letter, because A and C limit at 5 A while B, D and E limit at 10 A.
- The sense mode for the diagnostic in question, standard for load current and high accuracy for open load.
- The thermal copper under the pad at the real load current, using the 55 milliohm maximum.
- The clamp energy against the coil being driven, since the clamp has a current limit of its own.
- The logic level of the controller, which the inputs accept down to 1.8 V.
- The package option, because the 14 pin HTSSOP is not available on every version.
Which projects this part fits
The document names digital output modules, safe torque off circuits, holding brakes on a 24 V field supply, and general resistive, inductive and capacitive loads. The holding brake case is a good illustration: the switch has to hold a coil on continuously, survive the kick when it releases, and report an open coil before the machine is enabled.
Questions that come up before a purchase order is released
What does the A version limit at?
1 A to 5 A in 0.5 A steps. The B, D and E versions go from 2 A to 10 A. The body and the pinout are shared, so the letter is the whole difference.
Is 6 A a continuous rating?
The document describes the part as driving loads up to 6 A DC and pairs that with a thermal section. Continuous current in a sealed box depends on the copper and the ambient, so the thermal calculation decides it rather than the headline figure.
How is open load detected when the channel is off?
A small bias is applied and the resulting voltage is compared against a threshold. That is why the high accuracy sense mode exists, since the current involved is in the milliamp range.
Does the part need an external clamp on a brake coil?
It has an integrated clamp above 65 V. A coil with more stored energy than the clamp can take still needs an external device, and the clamp current is printed in the electrical characteristics.
How SUPERB handles this line
Industrial output channels are bought in sets: the switch, the clamp, the connector and the field wiring terminals all belong to one build. Our power management cross reference covers the switch families this part replaces. Our supplier quality audit describes the records we require for a functional safety capable part, and our kitting service is how a mixed bill of that kind is shipped.