TPS26612DDFR
Product Specifications
TPS26612DDFR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS26612DDFR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS26612DDFR 50 V current loop protector with a 32 mA bipolar limit
The TPS26612DDFR comes from the TPS2661x family, a set of parts made for one job: sit in front of a 4 mA to 20 mA current loop and keep the loop alive through the wiring mistakes that field installers make. The part holds a 50 V working rating and a 55 V absolute maximum, so a miswired 24 V field supply across the loop, or a reversed supply, does not reach the sense resistor and the ADC behind it. Inside the eight pin package there is a pair of pass FETs, a fixed bipolar current limit of 32 mA, a loop current sense path and a small charge pump that keeps the switch working when the loop sits below the supply rail.
The suffix carries behaviour rather than silicon. The TPS26612 is the latch-off member with a start-up allowance: the overload expiry timer is disabled for the first fault after power-up for up to five seconds, which is the window a two wire transmitter needs to charge its own reservoir and come up. Older members of the same family without that allowance fold back at 1.6 seconds and can leave a transmitter stuck in current limit on every power cycle. That single difference is why this string exists in the table at all.
Key parameters taken from the TPS2661x document
| Working voltage | 50 V across the loop, 55 V absolute maximum on the input and output pins |
| Current limit | Fixed bipolar limit, 25 mA minimum, 32 mA nominal, 40 mA maximum, in both directions |
| Start-up limit | The MODE pin can be set for twice the limit during start-up so a transmitter with a large input capacitor still comes up |
| On resistance | 7.5 milliohm typical for the pass pair, which keeps the loop burden and the headroom loss small |
| Quiescent current | Below 100 nanoamp drawn from the loop when the part is powered from an external supply |
| Supply options | External bipolar supply from 2.25 V to 20 V, or a unipolar supply from 3 V to 30 V |
| Fault response | Latch-off, with the overload expiry timer disabled for the first fault after power-up for up to 5 s on this member |
| Status output | SGOOD, an open drain flag that follows the health of the protected path |
| Control | Enable pin, plus the MODE pin that sets the limit multiplier and the timer behaviour |
| Transient ratings | Surge per IEC 61000-4-5 and fast transient per IEC 61000-4-4, both with an external TVS on the loop |
| Harmful event coverage | Miswiring on the input and on the output, thermal shutdown with hysteresis |
| Package | SOT-23, eight pins, 2.9 mm by 1.6 mm body, which the document puts at roughly half the area of a discrete protection circuit |
| Protocol fit | Listed as HART compliant, so the signalling band on top of the loop current is not disturbed |
| Order code note | DDF is the eight pin SOT-23 body, R is the large reel tape |
The rows above come from the vendor document rather than from a distributor summary. The current limit is printed as a window, and the window is what a test fixture should use. The nominal 32 mA is the centre, not a guaranteed clamp point.
Where the numbers matter in a real build
The first thing that surprises people is the limit window. A module that is checked against a 40 mA over-range spec passes on a part that clamps at 40 mA, but the same module tested with a 30 mA over-range expectation fails. Since the datasheet gives 25 to 40 mA as the spread over the full production population, an analog input module that has to survive a 40 mA loop without measurable offset has to plan the burden resistor and the ADC range around the top of that window, not around 32 mA.
The second is headroom. With 7.5 milliohm in the path, a 20 mA loop drops 150 microvolt, so the part is almost invisible to the measurement. That matters in a multiplexed input where eight channels share one ADC: a part with a ten ohm sense element would put 200 millivolt of channel dependent error into the reading, and the calibration table would have to carry a per channel term.
The third is the start-up window on this member. A two wire transmitter draws its whole operating current through the same pair that carries the signal, and the first seconds after power-up are exactly when a large reservoir capacitor looks like a short. The five second allowance is the feature that separates a card that starts every time from one that starts only when the ambient is warm and the capacitor is not fully discharged.
- Whether the board needs latch-off or auto-retry, because the difference is one digit in the order code and it changes the field behaviour after a fault.
- The burden resistor value against the top of the 25 to 40 mA limit window, not against the nominal figure.
- The external TVS, because the surge and fast transient ratings in the document are quoted with that device fitted.
- The MODE pin resistor, since it sets both the start-up multiplier and the timer behaviour.
- The thermal path in a sealed enclosure, because eight channels of protection in one small box share the same air.
- The reel and the moisture label when the parts go through a reflow line, since the SOT-23 body is small and the floor life matters more than the body size suggests.
Which projects this part fits
The document lists factory automation and control PLC analog input and output modules, motor drive control, HART inputs, HVAC controllers, UART input and output protection and thermal controllers. The common thread is a signal wire that leaves the cabinet and comes back, where the field side can be wired to the wrong terminal or sit at a different ground potential than the board.
Questions that come up before a purchase order is released
How is the TPS26612 different from the TPS26614?
The 612 latches off after a fault and carries the five second start-up allowance. The 614 retries on its own and is aimed at multiplexed voltage and current inputs. Both share the 50 V rating and the 32 mA limit.
Does the part protect the loop when it is unpowered?
The loop path is protected in both directions, but loop testing without a supply rail is a feature of the TPS26610 and TPS26613 only. On the 612 the loop is not passed through when the device has no supply.
Can two channels share one external supply?
Yes. The external supply pin draws almost nothing and the part is powered from it only to drive the switch, so one 20 V rail can serve a card full of channels.
What happens on a reversed field supply?
The internal blocks turn the path off and the 55 V rating holds the stress. The document covers input and output miswiring as named conditions rather than as an afterthought.
Is the limit accurate enough for a HART loop?
The limit is a protection threshold, not a measurement. HART signalling rides on top of the loop current and the part is listed as HART compliant, but the signalling amplitude has to be checked on the finished module with the burden in place.
How SUPERB handles this line
These parts sit on analog cards where the board also carries the ADC, the reference and the isolated supply, so the purchasing job is usually a whole card rather than one reel. Our power management cross reference covers the protection devices this family replaces, and the pin to pin cross reference lists the checks a substitute has to pass before it goes on a released board. Where the module needs the protector, the burden resistors and the connector in one shipment, our kitting service is the route we quote.