Contact Us

TPS259521DSGR

Brand: Texas Instruments
Texas Instruments TPS259521DSGR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS259521DSGR — Power Management & Signal Chain | Superb Automation

TPS259521DSGR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS259521DSGR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS259521DSGR: 2.7 V to 18 V, 4 A eFuse with a 3.8 V output clamp

TPS259521DSGR is an integrated FET hot swap device with a fixed output clamp in a WSON body of 8 pins. It sits between a 2.7 V to 18 V rail and a load that may surge or short, and it retries on its own after a thermal fault.

Order code and package

Order codeTPS259521DSGR, DSG package, 3000 pieces on a large reel
BodyWSON, 2.00 mm by 2.00 mm, eight pads plus the exposed pad
Clamp option3.8 V typical, 3.65 V to 4.1 V over the full temperature range
Fault responseAuto retry after thermal shutdown, 93 ms retry interval
EnableActive high on EN/UVLO with a 1.2 V threshold and 100 mV of hysteresis

Electrical parameters that decide the application

Input range2.7 V to 18 V operating, 20 V absolute maximum
On resistance34 mOhm typical at 25 C, 47 mOhm over -40 C to 85 C, 53 mOhm over the full range above 4 V input
Current limit0.5 A to 4 A set by one resistor, 7.5 per cent accuracy, 487 Ohm gives 4.42 A maximum
Limit equationRILM equals 2000 divided by the limit in amps minus 0.04
Clamp response5 us at 4 A and 10 us at 100 mA, no external part needed
Quiescent current175 uA typical and 250 uA maximum on, 0.45 uA at 5 V to 18 V off
Thermal157 C trip, 5 C hysteresis, 93 ms retry, 65.6 C/W junction to ambient
Slew rate16.3 V/ms at 3.3 V with the dVdt pin open, 10.0 V/ms with 3300 pF

Family variants and how they differ

TPS259520Same die with latch off instead of auto retry, for a rail that must stay down after a fault
TPS259525Quick output discharge pin in place of the fault flag, 19 Ohm discharge path
TPS259530 and TPS2595315.7 V clamp version of the same latch off and retry pair
TPS259540 and TPS25954113.7 V clamp for a 12 V rail
TPS259573Programmable overvoltage lockout instead of a fixed clamp, active low enable

Points to check before this part goes on a BOM

The 4 A figure is a switch rating, not a thermal promise. At 4 A through the 53 mOhm full temperature value the part dissipates 0.85 W, and 65.6 C/W takes the junction 56 C above ambient, so a 70 C enclosure already reaches the 125 C limit. At 2 A the same arithmetic gives 0.21 W and a 14 C rise, which is where the part sits comfortably.

The 3.8 V clamp option belongs on a 3.3 V rail. A 5 V rail needs the 5.7 V member and a 12 V rail the 13.7 V member. The rule is that the clamp must sit above the highest legal value of the input rail and below the absolute maximum of everything downstream, and with a 3.65 V to 4.1 V window there is no room above a 3.3 V rail that is allowed to run five per cent high.

The limit window is 7.5 per cent, which is tight for a hot swap part but still a window. A 2 A limit calls for a 1020 Ohm resistor and gives 1.85 A to 2.15 A spread across parts. A steady load must stay under the low end, and the inrush has to be over before the load starts, otherwise a part at the bottom of the window holds the rail in constant current and the downstream regulator never comes out of undervoltage lockout.

Inrush is set by the dVdt pin and nothing else. The slew rate needed is the inrush current divided by the load capacitance, so 1 A into 100 uF asks for 10 V/ms. The 3300 pF value that the data sheet characterises gives exactly 10 V/ms at 3.3 V, and the turn on delay of 147 us is on top of the 330 us ramp. A larger output bank has to move the capacitor value up in proportion, and the largest allowed value is 5000 pF.

The retry behaviour shapes the failure signature. After thermal shutdown the part waits for 5 C of cooling and then 93 ms before it tries again, so a permanent short shows up as a rail that pulses at roughly 11 Hz rather than one that stays dead. That is easy to see on a scope and hard to see on a voltmeter, and a firmware health check that samples once a second can miss it entirely.

The fault flag does not cover overcurrent. The table lists it for overtemperature, overvoltage, an open or shorted ILM pin, and a current above the circuit breaker level, but not for a plain current limit event. Firmware that waits for FLT to report a shorted port will never see one, so the output voltage has to be monitored as well.

The data sheet makes no reverse current blocking claim for this family. If the output can be held above the input by a second source or by a battery, a separate blocking device is needed. The TPS2662x family does state reverse blocking for its back to back body, so the two are not interchangeable on a shared node.

The current monitor shares the ILM pin with the limit resistor, and the stated ratio of output current to ILM current is about 276 to 1. That makes the pin voltage a load current signal for an ADC, but it also means the pin carries the limit setting, so a monitor reading taken while the part is in current limit says nothing useful about the load.

The 20 V absolute maximum is only 2 V above the operating limit, and a hot plug on a long cable can ring past it. What absorbs that ring is the input capacitor, and the data sheet asks for 0.1 uF close to the IN pin. A 10 uF bulk capacitor 20 mm away leaves the pin to take the cable inductance di/dt on its own, and the clamp conducts before the bulk part can help.

The dVdt pin is also the discharge path for the internal ramp, and leaving it open is the fastest turn on the part allows. That is 16.3 V/ms at 3.3 V, which into a 10 uF load is 163 mA of inrush and into 100 uF is 1.6 A, above the 4 A limit only for a fraction of a millisecond but long enough to be visible on a current probe. A load above 100 uF should have a capacitor on the pin rather than a hope that the limit catches it.

Where this order code fits

The part belongs on a 3.3 V or 5 V rail that feeds a connector, a drive bay or an add in card where a short is a field event. It is the smallest way to add a limit, a clamp and a retry to a port that has none. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the BOM Shortage Recovery page.

Questions buyers ask

What replaces it if the reel is short? The TPS259530 gives the same function with a 5.7 V clamp, and the TPS259520 gives latch off behaviour in the same body. Neither is a change of pin out, only of behaviour.

Does it protect against a reverse connected supply? Not on its own. This family has no reverse blocking specification, so a connector that can be back fed needs a blocking FET or the TPS2662x family.

Can the limit be changed after assembly? Yes, the limit is one resistor from ILM to ground. A 1020 Ohm part gives 2 A and a 1420 Ohm part gives about 1.45 A, so a single reel covers a range of port ratings.

What happens on a hard short? The part limits to the set current, the output collapses, the junction rises, thermal shutdown opens the FET, and the 93 ms retry cycle starts. The flag asserts only at the thermal event.

Does the clamp protect the load or the part? Both, indirectly. It holds the output at about 3.6 V while the input rises, so a load rated for 3.6 V survives, and the part survives because the clamp absorbs the difference as heat for as long as the event lasts.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Pin to Pin Cross Reference page sets out the checks that keep a substitute from failing on the bench.