Texas Instruments TPS259474ARPWR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS259474ARPWR — Power Management & Signal Chain | Superb Automation

TPS259474ARPWR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS259474ARPWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS259474ARPWR 5.5 A eFuse with a circuit breaker and a power good output

The TPS259474ARPWR is the circuit breaker member of the TPS25947 family. It operates from 2.7 V to 23 V, carries a pair of back to back FETs with a typical 28.3 milliohm path, and protects the load with an adjustable overvoltage lockout, an adjustable overcurrent threshold, a blanking timer and a thermal shutdown. Where the 470A regulates the current during an overload, this member opens the switch.

That one difference changes how a fault is measured. A current limited part holds the load at the limit and lets the load decide the voltage, while a circuit breaker carries the current for the blanking interval and then removes it entirely. On a board with a downstream converter that can tolerate a brownout but cannot tolerate a hard cut, the choice between the two members is a system decision rather than a price decision.

Key parameters taken from the TPS25947 document

Input range2.7 V to 23 V operating, 28 V absolute maximum, minus 15 V withstand on the input
On resistance28.3 milliohm typical across the back to back pair
Overcurrent responseCircuit breaker, set by one resistor on the ILM pin, 0.5 A to 6 A with ten per cent accuracy above 1 A
Published limit points6.65 k for 0.575 A, 3.32 k for 1.15 A, 1.65 k for 2.2 A, 750 ohm for 4.84 A, 549 ohm for 6.6 A
Blanking timerCapacitor on ITIMER, 1.8 microamp pull-down during an event, so peak loads above the limit pass for a bounded time
Fast trip500 ns typical on a short, threshold tied to twice the set limit
Overvoltage lockoutAdjustable with a divider on the OVLO pin, 1.2 microsecond typical response
Power goodOpen drain PG output with an adjustable PGTH threshold, 1.20 V rising and 1.09 V falling typical
Undervoltage2.53 V rising and 2.42 V falling typical, adjustable upward
Current monitorAnalog output on the ILM pin, 182 microamp per amp typical, six per cent accuracy above an amp
Thermal shutdown154 degrees junction rising, 10 degrees hysteresis, then the retry delay on the A member
PackageVQFN-HR RPW, ten pins, 2 mm by 2 mm, 0.45 mm pitch
Carrier3000 pieces on a large reel, moisture level 2 at 260 degrees with a one year floor life
Marking and grade2ACH on the A row, rated minus 40 to plus 125 degrees junction
RecognitionUL 2367 file E339631 and IEC 62368-1 CB certification

The table is read from the vendor document, and the marking row is worth keeping next to the purchase order, since the same body ships under the A and L strings and only the printed code separates them on a reel.

Where the numbers matter in a real build

A circuit breaker needs a timer that matches the load, because the part is not there to hold a fault current, it is there to decide when a current is a fault. The document puts the timer on the ITIMER pin, with a 1.8 microamp pull-down that discharges an external capacitor once the load passes the set limit, and it resets the capacitor whenever the load falls back below the limit. A motor start or a disk spin-up therefore passes through untouched if the pulse is shorter than the timer, while a shorted output trips the breaker after the same interval. The practical rule is to set the timer just above the longest legitimate peak in the product, and then check that the pass FET survives that peak thermally.

The power good output is the part of this member that the 470A does not have. PGTH is compared against a divider on the load side, with a 1.20 V rising threshold and 1.09 V falling threshold, so the flag asserts high only when the path is fully on and the monitored rail has reached its own threshold. A board that sequences two rails off this flag gets a clean handover, while a board that sequences off the enable pin alone can release the second rail while the first is still in inrush.

The current monitor shares the ILM pin with the limit resistor. The gain is given as 182 microamp per amp typical, so a 4 A load produces about 0.73 mA into the sense resistor, and the six per cent accuracy applies above one amp. Below that the offset dominates, which is why the document qualifies the accuracy figure rather than quoting one number for the whole range.

The overvoltage lockout on this member is an adjustable cutoff rather than a clamp. That means an overvoltage event removes the output instead of holding it at a fixed level, and the 1.2 microsecond response is what keeps the downstream converter from seeing the surge. The family does carry a clamped alternative on the other members, where the output is held at a fixed level and the FET absorbs the difference, and a buyer who needs clamping should order that member rather than this one.

Thermal behaviour closes the loop. A long overvoltage event with a load attached can push the die to 154 degrees, at which point the part shuts down, and the A member waits for the die to cool by ten degrees and then for the retry delay before it tries again. A board that keeps a fault on the input can therefore cycle rather than stay off, which is the intended behaviour for an unattended product and the wrong behaviour for a product that has to report a single hard failure.

  • The A or L suffix, because a retry pattern and a latched pattern look identical on a bench with a resistive load.
  • The timer capacitor against the real peak load, and against the peak the pass FET can carry for that long.
  • The PGTH divider, since the flag is only useful if its threshold sits above the point where the load can work.
  • The lockout divider, because a 24 V adapter is close to the top of the 23 V range and the divider sets the margin.
  • The reel and the marking, since the level 2 moisture rating carries a one year floor life.

Which projects this part fits

The vendor lists power MUX and ORing, adapter input protection, USB PD protection in computers and docks, server motherboards and add-on cards, enterprise storage and patient monitors. The circuit breaker version suits a rail that feeds a converter with a defined input window, where removing the load for a moment is safer than holding it at a reduced voltage.

Questions that come up before a purchase order is released

Can this part limit current instead of breaking the circuit?

No. The 474A opens the path after the blanking interval once the set limit is passed. The 470A and 472A members of the same family are the ones that regulate the current.

What does the power good output monitor?

It compares the PGTH pin against an internal 1.20 V reference and asserts high when the path is fully on. The divider on PGTH therefore decides which rail voltage counts as good.

Is the retry delay adjustable?

No. The retry interval is fixed internally. The adjustable timer is the blanking interval on ITIMER, which is a different function.

How much current can the part carry continuously?

The family is rated as a 5.5 A part with a 28.3 milliohm path. At the top of the current range the dissipation in the 2 mm body is the limiting factor, so the copper area under the part belongs in the thermal calculation.

What happens on a hard short?

The fast trip path responds in about 500 ns at twice the set limit, well before the blanking timer, and the part then follows the retry or latch behaviour of the suffix.

How SUPERB handles this line

The buying decision on this family is usually between two members that share a body and a reel, so the work is in confirming the suffix and the peripheral parts rather than in finding the device. Our power management cross reference holds the replacement mapping, and our incoming inspection plan covers how a reel is checked against the order before it reaches a line. For programmes that need the eFuse, the divider resistors and the timer capacitors from one shipment, our one stop BOM sourcing service is the route we quote.