Contact Us

TPS259470LRPWR

Brand: Texas Instruments
Texas Instruments TPS259470LRPWR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS259470LRPWR — Power Management & Signal Chain | Superb Automation

TPS259470LRPWR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS259470LRPWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS259470LRPWR: 23 V, 5.5 A eFuse with true reverse current blocking and a latch off fault response

TPS259470LRPWR is a protected front end that replaces a fuse and a reverse blocking diode with one 28 milliohm part in a VQFN-HR body of 10 pins. It conducts up to 5.5 A from a 2.7 V to 23 V rail through 28.3 milliohm of back to back FET, survives 28 V and minus 15 V transients, and blocks reverse current in both the on and off states. The L suffix in this order code gives a latch off response to a fault instead of an automatic retry.

Order code and package

TPS259470LRPWR10 pin VQFN-HR (RPW), 3000 pieces on a large reel, marking 2A8H
TPS259470ARPWRsame body and limits, auto retry after a fault instead of latch off
On resistance28.3 milliohm typical for the back to back pair, measured at the vendor test condition
Current rating5.5 A continuous, with the limit set by an external resistor on the ILIM pin
Moisture levellevel 2, 260 C, one year floor life, so the reel has a clock on it once it is opened

Electrical parameters that decide the application

Input voltage range2.7 V to 23 V operating, 28 V absolute maximum
Negative inputwithstands minus 15 V on the input without conducting in the reverse direction
Current limitadjustable by resistor, up to 5.5 A, active current limiting rather than a breaker
On resistance28.3 milliohm typical for the complete back to back path
Reverse blockingtrue reverse current blocking in both the enabled and the disabled state
Overvoltageadjustable overvoltage lockout on this member, set by a divider on the OVLO pin
Fault outputpower good and a fault threshold pin, both open drain
Response to faultlatch off on the L member, auto retry on the A member, the only difference between the two order codes
Temperature rangeminus 40 C to plus 125 C junction

The three current members and the two fault responses

TPS259470adjustable overvoltage lockout and active current limit, the row on this page
TPS259472pin selectable overcurrent with a circuit breaker response rather than active limiting
TPS259474adjustable overvoltage lockout with a circuit breaker response
A suffixauto retry, the part re enables itself after the fault clears and the load sees power again without intervention
L suffixlatch off, the part stays off until the enable pin is cycled, which is what a serviceable product usually wants
Power goodopen drain, usable to hold a downstream converter off until the input is valid

Points to check before this part goes on a BOM

The 28.3 milliohm figure is the reason this part replaces a fuse. At 5 A a conventional fuse and a Schottky diode in series drop several hundred millivolts between them, which at 5 A is a couple of watts of heat and a volt of lost headroom. A back to back FET pair at 28 milliohm dissipates 0.7 W at the same current, and it does it in a 10 pin package with no replaceable part to stock.

True reverse current blocking is the feature that separates this family from a load switch. With the part disabled and the output held up by another source, no current flows backwards into the input, and with the part enabled the same holds until the reverse comparator trips. On a power multiplexer or a battery backed board that is the difference between a controlled switchover and a discharge path through the body diode.

The latch off response is a service decision as much as an electrical one. A board that latches off after an overcurrent stays off until something cycles the enable pin, which is what a product with a user accessible switch wants, and it is what a remote installation wants too because it prevents a fault from retrying into a short indefinitely. The auto retry member is for equipment that must recover without a technician, and the two are the same silicon with a different option.

The minus 15 V negative input rating is not a curiosity, it is the automotive and hot plug case. A connector that is plugged in reverse, or an inductive load that rings below ground when it is disconnected, will pull the input pin negative, and a part with a body diode conducts straight through that event. This family blocks it, which is why it appears on adapter input protection and on boards with a connector a user can reach.

The overvoltage lockout is adjustable on this member and fixed by pin strap on the 472, which is a real difference when a product has to survive a 24 V adapter being plugged into a 12 V input. The divider on the OVLO pin sets where the part turns off, and the part turns back on when the input falls, so a transient above the divider point does not destroy the load even though the part has no clamp of its own.

The current limit is active rather than a breaker on this member, which means the part holds the current at the set level while the fault persists instead of opening. That protects the load from a surge and it also heats the part, because the FET is now dropping the difference between the input and whatever the load is doing. A sustained limit event is a thermal event, and the thermal pad on the RPW body is there for exactly that reason.

Moisture level 2 with a one year floor life is a handling constraint that shows up in production rather than in the datasheet tables. Once the reel is opened the clock starts, and a line that keeps a partial reel for eighteen months has to bake it before use. That is worth stating on the incoming inspection sheet for this part, because the failure mode from absorbed moisture is a cracked package after reflow, not an electrical fault that a test catches.

The 10 pin body carries its thermal pad underneath, so the pad has to be soldered to a copper area with vias if the part is expected to survive a current limit event. A footprint that treats the pad as mechanical and leaves it unconnected will pass a functional test and fail in the field on the first sustained overcurrent. That is the one assembly detail worth confirming on this part before a build is released.

Where this order code fits

It sits at the input of an adapter powered board: server and storage front ends, USB power delivery ports, industrial controllers with a field connector, and any product where a reversed or hot plugged supply has to be survived. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the BOM Shortage Recovery page.

Questions buyers ask

What is the difference between the A and the L order codes? Fault response only. The A member retries automatically once the fault clears, the L member latches off and needs the enable pin cycled.

Does it need an external fuse as well? No. The current limit is set by a resistor on the ILIM pin and the part limits actively. A fuse in series would add resistance and defeat the point of a 28 milliohm path.

Can current flow backwards through the part? No, not in either state. That is the true reverse current blocking feature, and it is what allows the part to sit between two supplies.

Is the current limit accurate enough to use as a fuse? The limit is a current sense threshold with a tolerance window, so it should be treated as a protection level rather than as a precision measurement.

What sets the overvoltage trip? A divider on the OVLO pin on this member. The 472 member has pin selectable overcurrent instead and a breaker response.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Obsolete RF Part Replacement page sets out the checks that keep a substitute from failing on the bench.