TPS2592ALDRCR
Product Specifications
TPS2592ALDRCR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS2592ALDRCR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS2592ALDRCR 12 V eFuse with overvoltage clamp and blocking FET control
The TPS2592AL is a 12 V eFuse: a pass FET, a current limit, an overvoltage clamp and a thermal shutdown in one 3 mm by 3 mm body. It replaces a fuse, a TVS and a handful of discrete parts on a 12 V rail, and it does so with a current limit that the board can set with one resistor and a ramp that it can set with one capacitor.
The part is marked NRND on the vendor addendum, which is a status a buyer has to plan around. The silicon is still in production and the document is still current, but the vendor no longer wants new programmes to start on it, so a programme that is already shipping should be looking at a last time buy rather than at a second source with a different pinout.
Key parameters taken from the TPS2592ALDRCR document
| Operating range | 4.5 V to 13.8 V, with 20 V absolute maximum on the input |
| Pass FET | 28 milliohm integrated switch |
| Current limit | 2 A to 3.7 A adjustable with one resistor, at 15 per cent accuracy |
| Overvoltage clamp | 13.8 V minimum, 15 V typical and 16.5 V maximum, fixed internally |
| Undervoltage lockout | 4.15 V minimum, 4.3 V typical and 4.45 V maximum on the input rising, with 5.4 per cent of hysteresis |
| Enable threshold | 1.37 V minimum, 1.4 V typical and 1.44 V maximum on the enable pin rising |
| Supply current | 0.2 mA minimum, 0.42 mA typical and 0.65 mA maximum enabled, 0.1 mA typical when disabled |
| Ramp control | One capacitor on the ramp pin, with a 220 nA charging current and a 4.85 V per volt gain to the output |
| Fast trip | 160 per cent of the set current limit, which is the level that produces the fast turn off |
| Fail safe | An open limit resistor drops the current to about 0.55 A and a shorted one raises it to about 3.75 A, both covered by the single point failure test |
| Reverse blocking | A dedicated control pin drives an external FET back to back with the internal one |
| Thermal | Internal shutdown, with the current limit loop as the first line of protection |
| Approvals | UL 2367 recognized, file E169910, and safe during the UL 60950 single point failure test |
| Package | VSON of 3 mm by 3 mm, ten pins |
| Carrier | 3000 pieces on a large reel, with a 250 piece small reel row |
| Moisture | Level 1 at 260 degrees with an unlimited floor life |
| Part marking | 2592AL |
| Status | Marked NRND on the addendum, which means the vendor does not want new programmes to start on it |
Every row above is read from the vendor document, not from a distributor summary. Where a window is printed, the window is what a production test should use, and the typical value is only a starting point for a first article.
Where the numbers matter in a real build
The single point failure behaviour is the reason this part can be used on a safety rated rail. If the limit resistor opens, the current falls to about 0.55 A instead of rising; if it shorts, the current rises to about 3.75 A, which is still inside the pass FET rating. A fuse does not have that behaviour, and a discrete current limit built from a sense resistor can fail in either direction. The document prints both cases so a safety file can quote them.
The overvoltage clamp is fixed at 15 V typical with a 13.8 to 16.5 V window, which suits a 12 V rail that can see a load dump from an upstream converter. The clamp does not shut the path off, it holds the output at the clamp voltage, so a transient that lasts longer than the thermal time constant of the FET becomes a thermal event. A rail that can sit above 15 V for seconds needs a different arrangement.
The ramp capacitor is what keeps the inrush into a large load capacitance inside the current limit. The ramp pin charges at 220 nA and the output follows through a gain of about 4.85 volts per volt, so the capacitor value sets the time to reach the final output. A capacitor that is too small lets the current limit act during start up, which produces a fast edge and a current spike; too large and the load sits at an intermediate voltage for longer than the system expects.
The reverse blocking pin is for rails with holdup capacitance on the load side. If the input collapses, the load capacitor would otherwise discharge through the body diode of the pass FET back into the source, which on a shared bus can hold the bus up and prevent a proper restart. An external FET back to back with the internal one, driven from the blocking control pin, breaks that path.
The NRND status changes the buying conversation rather than the electrical behaviour. A programme that is already in production should set a last time buy quantity against its remaining build life, and a programme that is still in development should be moved to the current generation part, with the board change planned before the first production order.
- The limit resistor value, because the limit is set by one part and the 15 per cent accuracy has to be inside the load budget.
- The ramp capacitor, since the inrush into the load capacitance is set by that one part.
- The clamp voltage against the highest sustained input the rail can see, because the clamp holds rather than interrupts.
- The reverse blocking FET if the load has holdup capacitance, since the internal path alone does not block.
- The status on the addendum, because the part is NRND and a long life programme has to plan the last buy.
- The fail safe behaviour of the limit resistor, which is the row a safety file will quote.
Which projects this part fits
This part fits adapter powered devices, hard disk and solid state drives, set top boxes, server auxiliary rails, fan control boards and PCIe cards, which is the list the document prints. It also fits any 12 V branch that has to survive a load dump without a fuse that a field engineer cannot replace.
Questions that come up before a purchase order is released
What does NRND mean for a buyer?
The part is still in production and the document is current, but the vendor does not want new programmes to start on it. A programme in production should plan a last time buy, and a programme in development should move to the current generation part.
Is the current limit adjustable on the board?
Yes, with one resistor, across a 2 A to 3.7 A range at 15 per cent accuracy.
What happens if the limit resistor fails?
An open resistor drops the limit to about 0.55 A and a shorted one raises it to about 3.75 A. Both cases are printed, and both were part of the single point failure test.
Does the part block reverse current?
The internal path does not. A separate control pin drives an external FET back to back with the internal one for that function, which is the arrangement the document shows for loads with holdup capacitance.
How is the output ramp set?
By one capacitor on the ramp pin, with a 220 nA charging current and a gain of about 4.85 from the pin to the output.
Can the part be used above 13.8 V?
The recommended range stops at 13.8 V and the absolute maximum is 20 V. A 12 V rail with a load dump inside that window is covered by the clamp, but a rail that sits above 15 V for long is not.
How SUPERB handles this line
A 12 V eFuse is usually the last protection part left on a board after the converter has been chosen, so the decision is mostly about status and availability. Our power management cross reference lists the devices this part is cross referenced against, our last time buy planning covers the last time buy planning for parts that carry an NRND marking, and our obsolete part cross reference is where we keep the obsolete part routes that include this family.