Contact Us

TPS259260DRCR

Brand: Texas Instruments
Texas Instruments TPS259260DRCR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS259260DRCR — Power Management & Signal Chain | Superb Automation

TPS259260DRCR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS259260DRCR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS259260DRCR: the 12 V eFuse with a 15 V clamp

TPS259260DRCR is the 12 V member of the TPS25925x and TPS25926x eFuse family in the ten pin VSON body on a 3000 piece reel. The device puts a 30 milliohm pass FET, a fixed over voltage clamp, an adjustable current limit and a programmable ramp rate in one package that measures 3 mm by 3 mm, which is the whole reason the part exists: a discrete version of the same function needs a controller, a FET, a sense resistor and four passive parts around it.

SLVSCQ3B, revised June 2016, splits the family along the clamp voltage. The 25925x parts clamp at 6.1 V and are built for 5 V rails, the 25926x parts clamp at 15 V and are built for 12 V rails. The 259260 code within the 12 V group is the auto retry version and the 259261 is the latched version, which is the first thing to check when a string is specified.

What follows is what the clamp and the current limit actually do, the pin functions that decide the external parts, the thermal ceiling in a 3 mm body, and the difference between an eFuse and a fuse in a 12 V distribution board.

What the part does at the two edges

Over voltage is handled by an internal clamp rather than by a comparator and an external FET. On this string the clamp sits at 15 V, so a 12 V rail that sees a 24 V transient is held and the downstream load never sees the peak. The clamp is a fixed function, it cannot be programmed, and that is deliberate: the part is meant to be dropped into a rail whose normal and fault windows are already known.

Orderable codeTPS259260DRCR
BodyVSON, 10 pins, 3.00 mm by 3.00 mm
Carrier3000 pieces on a large reel
Moisture ratinglevel 2, 260 degrees for one year floor life
Operating ambient in the tableminus 40 to 85 degrees
Input voltage window4.5 V to 13.8 V on the 12 V group
Absolute maximum on the input20 V steady, 22 V for transients shorter than 1 millisecond
Pass FET resistance30 milliohms
Current limit range2 A to 5 A, set by one resistor on the ILIM pin
Current limit accuracyplus or minus 15 percent typical
Over voltage clamp15 V fixed on this group, 6.1 V on the 5 V group
Fault responseauto retry, latched on the 259261 string
Ramp controlone capacitor on the dV/dT pin sets the output slew
Enable and under voltageone pin, resistor divider sets the turn on threshold
Thermal protectioninternal shutdown with restart after the junction cools
Safety approvalsUL 2367 recognised, file number E339631, and UL 60950 single point failure
Continuous output current5 A, limited by the FET and the board

The current limit in practice

The limit is set by a resistor from the ILIM pin to ground, and the data sheet prints the relationship as a table rather than as a single equation. A 130 k ohm resistor gives the 5 A maximum, which is also the condition under which the UL 2367 recognition applies, so a board that sets a lower limit is outside the recognised configuration and has to be evaluated on its own. That detail is easy to miss and it matters in a product that leans on the eFuse for a safety claim.

Accuracy of plus or minus 15 percent means a 3 A setting can trip anywhere between 2.55 A and 3.45 A. A load that draws 3 A continuously sits inside the tolerance band, so the limit has to be set above the maximum load by more than 15 percent or the part will trip on a good board on a hot day. The usual rule is to set the limit at 1.4 times the maximum load current and to size the FET and the board for the resulting fault current.

The ramp rate is a separate knob and it exists because of inrush. A 12 V rail with 470 microfarads of downstream capacitance and no ramp control draws a current step that the source sees as a short, and on a hot plug connector that step is what welds the pins. The dV/dT capacitor turns the pass FET into a current source during start up, so the inrush is set by the capacitor and not by the load capacitance, and the data sheet prints the relationship between the capacitor value and the ramp time.

Thermal ceiling in a 3 mm body

The 30 milliohm FET dissipates 0.12 W at 2 A and 0.75 W at 5 A. In a 3 mm by 3 mm body with the thermal pad soldered to a plane, the junction to ambient figure is around 45 degrees per watt on a four layer board with the recommended via pattern, so a 5 A continuous load sits 34 degrees above ambient, and a 5 A load in a 70 degree enclosure reaches 104 degrees junction, which is inside the 125 degree limit but leaves little room for a fault.

The fault case is what sizes the board. During a short the part limits at the set value, and the dissipation becomes the input voltage times the limit current, which at 12 V and 3 A is 36 W for as long as the thermal shutdown takes to act. The data sheet section on short circuit measurements is explicit that the package survives this, but only with the recommended copper, so a plane of at least the area shown in the example is part of the circuit and not a suggestion.

The resistance also moves with temperature. A 30 milliohm figure at 25 degrees becomes roughly 42 milliohms at 125 degrees on a silicon FET, which raises the 5 A dissipation from 0.75 W to 1.05 W and the junction rise from 34 to 47 degrees. A board that passes at the bench and fails in the chamber is usually one that used the 25 degree figure.

An eFuse against a fuse in a 12 V rail

A fuse protects the wiring and does nothing for the load. An eFuse protects the load as well, because the limit acts in microseconds and the clamp holds the rail through a transient, and it also gives a status signal and a controlled restart. The trade is that the eFuse needs a bias and a ground, it has a leakage path when off, and it does not replace a fuse for a catastrophic fault, so the two are usually fitted together in a distribution board.

The 12 V group is the right choice wherever the rail is a battery or an adapter output in the 9 V to 13.2 V band, which covers set top boxes, drives, servers and PCIe cards, the four application groups the document names. A 5 V rail with the same part would sit above the clamp and never conduct, which is why the 25925x group exists and why the two must not be mixed in a bill of materials.

Where the rail is hot plugged, the ramp capacitor is the part that decides whether the connector survives. Where the rail feeds a load that must not restart into a fault, the latched string is the right one, because the auto retry version will attempt a restart every thermal cycle and a hard short will keep the board in that loop. The power management cross reference page lists the pin compatible alternatives in this family, and the pin to pin cross reference page covers how we check a substitute that has a different clamp voltage before it goes on a board.

Questions that come with this string

Is the 15 V clamp the working voltage or the fault voltage? It is the fault threshold. The input window for normal operation is 4.5 V to 13.8 V, and the clamp is the level the part holds the output at when the input exceeds the window. Running a 15 V rail through this part would keep it in clamp continuously.

Can the current limit be set below 2 A? The printed range starts at 2 A and the UL recognition is tied to a 130 k ohm resistor at the top of the range. A lower setting is possible on the bench and outside the recognised configuration, so it needs its own evaluation.

What happens on a hot plug event with no dV/dT capacitor? The pass FET turns on in its fastest mode and the inrush is limited only by the load capacitance and the source impedance, which on a 12 V adapter is a current step of tens of amps for a few microseconds. The part will limit, but the connector and the source see the step.

How is the part tested on a production line? A functional check of the enable threshold, the output ramp and the current limit at one point is enough to catch a wrong resistor or a wrong string, and the clamp is verified once per lot rather than per board because it is internal and fixed. The incoming inspection plan covers the reel level checks that come before that.