TPS25810RVCR
Product Specifications
TPS25810RVCR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS25810RVCR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS25810RVCR USB Type-C downstream facing port controller with an integrated 3 A power switch
The TPS25810 is the controller for the port that supplies power, which the Type-C specification calls a downstream facing port. It watches the configuration channel lines, decides when a device has been attached and what it is, advertises the current the port can supply, and switches VBUS through an integrated 3 A FET. It also detects a debug or audio accessory, which is the case most controllers ignore.
The switch is a 34 milliohm high side FET with two fixed current limits that match the Type-C current levels, 1.7 A and 3.4 A. A load detection output lets a system turn off a high power 5 V supply when nothing is attached, and the part draws under a microamp in that state, which is what makes it usable in a product that has to meet a standby power target with the port always present.
Key parameters taken from the TPS25810RVCR document
| Input rails | 4.5 V to 6.5 V on IN1, 4.5 V to 5.5 V on IN2 and 2.9 V to 5.5 V on the auxiliary rail |
| Switch resistance | 34 milliohm typical at 3 A, 37 milliohm maximum at 25 degrees, 46 milliohm maximum at 85 degrees and 55 milliohm maximum at 125 degrees |
| Current limits | 1.58 to 1.82 A in the lower setting and 3.16 to 3.64 A in the upper setting, both fixed and selected by a pin |
| Reference | 0.78 V minimum, 0.8 V typical and 0.82 V maximum on the REF pin |
| Standby current | 0.7 microamp typical when no device is attached |
| Reverse leakage | 0 to 3 microamp from the output back to the input when the switch is off |
| Discharge | 500 ohm bleed on the output after a detach, plus a 150 k path on the configuration channel lines |
| Fault output | Open drain, 350 mV low level at 1 mA, asserted on overcurrent and overtemperature |
| Load detect | Separate output that reports an attached device, so the system can enable or disable the high power supply |
| Configuration channel | Attach and detach detection, current advertisement and polarity determination |
| VCONN | Power for an electronically marked cable, supplied from the dedicated VCONN input |
| Accessory detection | Audio and debug accessories are identified, which a plain charging controller does not do |
| Approvals | UL listed under file E169910 |
| Package | WQFN of 3 mm by 4 mm, twenty pins |
| Carrier | 3000 pieces on a large reel |
| Moisture | Level 2 at 260 degrees with a one year floor life |
| Part marking | 25810 |
| Temperature | Minus 40 to plus 125 degrees |
Every row above is read from the vendor document, not from a distributor summary. Where a window is printed, the window is what a production test should use, and the typical value is only a starting point for a first article.
Where the numbers matter in a real build
The two current limits are the two Type-C current levels, and they are fixed rather than programmable. A port that advertises 3 A has to be able to hold the upper limit, and the 34 milliohm switch gives 0.3 W at 3 A, which is manageable in a 3 by 4 mm body with a pad. A port that advertises 1.5 A uses the lower limit, and the same part covers both cases with one pin.
The standby current of 0.7 microamp is the number that decides whether the port can stay alive in a product that has to meet a low standby target. The device keeps watching the configuration channel while drawing almost nothing, and the load detect output tells the system when to bring up the main 5 V supply. Without that arrangement a notebook would have to keep its whole charger alive to notice a cable.
The auxiliary rail is what makes the low power states work. The controller can run from a 3.3 V housekeeping supply when the main 5 V rail is off, so the port can still detect an attach in suspend and wake the system, while the switch itself stays off because there is nothing to pass. That is the arrangement the sleep and hibernate states of a notebook depend on.
The reverse leakage row matters more than it looks. When the port is off and a device with its own battery is plugged in, the device VBUS appears at the output, and any leakage back into the input would charge the system rail from the device. The printed 0 to 3 microamp window at 6.5 V is what keeps that path negligible.
Accessory detection is the feature that separates this part from a charging only controller. A debug accessory presents a specific configuration channel signature, and a port that does not recognise it will simply refuse to supply power, which makes a factory test fixture fail for reasons that look like a hardware fault. The identification is internal and needs no firmware.
- The two rails, because the switch input and the auxiliary supply have different windows and both have to be present for the port to work in suspend.
- The current limit pin, since the advertised current has to match the limit the port can hold.
- The load detect output and what the system does with it, because it is the signal that enables the main supply.
- The switch resistance at the operating temperature, since 55 milliohm maximum at 125 degrees is the number for the thermal sum.
- The configuration channel protection, because those pins go to the outside world and the part protects the switch, not the connector.
- The reel and the moisture level, because a level 2 part needs a bake decision after a year.
Which projects this part fits
This part fits notebooks and tablets with a Type-C port, monitors and docking stations, charging cradles and any host product that has to supply power over Type-C and still meet a standby target. It also fits test equipment that has to recognise a debug accessory, since that identification is what makes a fixture work on the first try.
Questions that come up before a purchase order is released
Does the part support USB Power Delivery?
No. It is a Type-C controller with fixed current advertisement at 1.7 A and 3.4 A. A port that has to negotiate 9 V, 15 V or 20 V needs a power delivery controller instead.
What are the two current limits for?
They match the two Type-C current levels. The lower setting serves a 1.5 A port and the upper setting a 3 A port, and the pin selects between them.
Why does the part have three supply pins?
IN1 is the charging supply that feeds the switch, IN2 is the VCONN supply for an electronically marked cable, and the auxiliary rail keeps the controller alive when the main supply is off.
How much current does it draw with nothing attached?
0.7 microamp typical. That is what allows the port to stay supervised in a standby state without a measurable effect on the standby power figure.
Can it detect a debug accessory?
Yes. Audio and debug accessories are identified from the configuration channel signature, which a charging only controller does not do.
Is the switch protected against a short?
The current limit loop holds the output at 1.7 A or 3.4 A and the fault output asserts, with thermal shutdown as the last line. A permanent short is a fault the part handles, but the upstream supply still has to survive the interval before the limit acts.
How SUPERB handles this line
Type-C source controllers are bought on the current level they advertise and on how little they draw when nothing is plugged in, and both figures are printed in the vendor document. Our power management cross reference lists the devices this part is cross referenced against, our date code management covers the date code discipline we apply to mixed date lots on the same reel, and our one stop BOM sourcing service is the route when the controller, the connector and the passives have to ship as one kit.