Contact Us

TPS2560DRCR

Brand: Texas Instruments
Texas Instruments TPS2560DRCR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS2560DRCR — Power Management & Signal Chain | Superb Automation

TPS2560DRCR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS2560DRCR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS2560DRCR dual channel precision adjustable current limited power switch, 250 mA to 2.8 A per channel

The TPS2560 is the two channel member of the TPS256x family. It puts two independent current limited switches in one 3 mm by 3 mm body, each with its own limit resistor and its own fault flag, which is what a hub or a dual port charger needs when the two ports must be able to fault independently without taking each other down.

Each channel is a 44 milliohm high side FET with a limit that can be programmed from 250 mA to 2.8 A. The document prints the limit windows at three resistor values, and the accuracy at the top of the range is 7.5 per cent. The part also carries built in soft start, per channel fault outputs, undervoltage lockout and thermal shutdown, and the auto retry behaviour is built from an external resistor and capacitor on the enable pin rather than from a timer inside the body.

Key parameters taken from the TPS2560DRCR document

Operating range2.5 V to 6.5 V on the input
ChannelsTwo, independent, each with its own ILIMx pin, ENx pin and FAULTx output
Adjustable limit250 mA to 2.8 A typical per channel
Limit accuracy7.5 per cent at 2.8 A
Worked limit points2590 to 3005 mA at 20 k, 800 to 1005 mA at 61.9 k and 470 to 645 mA at 100 k
High side switch44 milliohm typical per channel
Overcurrent response3.5 microsecond typical
Supply current100 microamp typical and 125 microamp maximum with a 20 k limit resistor, 85 microamp typical and 110 microamp maximum at 100 k
Soft startBuilt in, which limits the inrush into the load capacitance
Fault flagOne per channel, open drain, asserted on overcurrent and overtemperature
Auto retryBuilt from an external resistor and capacitor on ENx, with the fault output releasing the enable and the capacitor timing the restart
Thermal shutdownInternal, with the current limit loop holding the channel until the die reaches the threshold
System ESD15 kV air and 8 kV contact at system level
ApprovalsUL listed under file E169910, CB and Nemko certified
PackageVSON of 3.00 mm by 3.00 mm, ten pins
Carrier3000 pieces on a large reel
MoistureLevel 2 at 260 degrees with a one year floor life
Part marking2560

Every row above is read from the vendor document, not from a distributor summary. Where a window is printed, the window is what a production test should use, and the typical value is only a starting point for a first article.

Where the numbers matter in a real build

Two channels in one body do not mean two independent thermal budgets. The two FETs share a die and a pad, so the temperature rise of one channel adds to the other. A product that runs both channels at 2.8 A continuously has twice the dissipation of a single channel board in the same package, and the datasheet dissipation ratings are printed per part rather than per channel, which is the row to read before assuming both ports can be loaded at once.

The auto retry path is external by intent. The fault output pulls the enable pin low, the enable pin discharges through an external resistor, the capacitor on the enable pin then charges through the same resistor once the fault clears, and the channel restarts. That gives the product a restart time it can set without a microcontroller, and it also means a board that ties the enable pin high can never retry, which is a common reason a port stays dead after a transient.

The three worked limit points are the practical calibration. A 20 k resistor gives 2590 to 3005 mA, a 61.9 k resistor gives 800 to 1005 mA and a 100 k resistor gives 470 to 645 mA. The windows are wide enough that a product with a 1 A load should not be set at a 1 A limit, because the low end of the window would trip it, and a product with a 500 mA load should not sit at the bottom of a 470 mA setting.

The 44 milliohm channel gives 0.35 W at 2.8 A, which in a 3 mm by 3 mm body with two channels needs copper on the pad. A dual port charger in a plastic shell is the case where this matters most, since both ports are often loaded at the same time and the ambient inside the shell is well above room temperature.

The system level ESD figures and the UL listing are printed for the part, and a product that needs them for a safety submission should quote them with the file number from the document. A test house will ask for the file number, not for a statement that the part is protected.

  • The two limit resistors against the two loads, because the two channels are set independently and the windows are wide.
  • The auto retry components on each enable pin, because a channel with the enable tied high cannot restart.
  • The combined dissipation with both channels loaded, since the two FETs share one die and one pad.
  • The fault outputs and how the system reacts to them, since a controller that latches on the first fault defeats the retry path.
  • The load capacitance per channel, because the soft start is what keeps the inrush inside the limit.
  • The moisture level, because a level 2 part needs a bake decision after a year on the shelf.

Which projects this part fits

This part fits USB hubs, dual port adapters, digital televisions with two USB sockets, set top boxes and voice over IP phones. It also fits any board with two branches that must be protected separately, such as a pair of peripheral connectors on an industrial controller, where one branch faulting should not take the other one down.

Questions that come up before a purchase order is released

Can the two channels be set to different limits?

Yes. Each channel has its own ILIM pin and its own resistor, so one port can be set at 2.8 A and the other at 900 mA from the same part.

Does the part retry by itself?

Not without an external network. The document describes the auto retry function as an external resistor and capacitor on the enable pin, with the fault output releasing the enable. A board with the enable tied high will stay off after a fault.

What is the difference between the TPS2560 and the TPS2561?

Both are covered by the same document and the same electrical table. The difference sits in the limit range and the accuracy at the top of it, so the orderable number has to be read against the device comparison table rather than assumed.

How much current can both channels carry at once?

Each channel is rated to 2.8 A, but the package dissipation is shared. Two channels at full load in a sealed enclosure will reach the thermal limit sooner than one channel, so the combined figure has to be checked against the dissipation rating and the ambient.

Is there a fault flag per channel?

Yes, one FAULTx output per channel, and each asserts independently on overcurrent or overtemperature for its own channel.

What happens below the undervoltage lockout?

The channels release and the loads lose their supply. The lockout is there to keep a partially collapsed rail from being passed to a connector.

How SUPERB handles this line

Dual channel switches are usually bought for a hub or a two port adapter, and the two things that decide whether the part works in that product are the limit windows and the shared thermal path. Our power management cross reference lists the devices this part is cross referenced against, our safety stock planning covers the stock planning we do on these small power parts, and our kitting service is the kitting route when both switches and the connectors have to arrive as one kit.