TPS2553DRVR-1
Product Specifications
TPS2553DRVR-1
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS2553DRVR-1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS2553DRVR-1: adjustable current limit switch with latch off on fault
TPS2553DRVR-1 is a single channel power switch with a resistor programmed current limit in a WSON body of 6 pins. The -1 suffix marks the latch off behaviour, so a fault turns the switch off and it stays off until the enable pin is cycled.
Order code and package
| Order code | TPS2553DRVR-1, DRV package, WSON six lead, 2.00 mm by 2.00 mm |
| Limit programming | An external resistor from ILIM to ground, 15 kOhm to 232 kOhm for stability |
| Limit range | About 75 mA at the top of the resistor range to 1.7 A typical at the bottom |
| Enable | Active low on this member, the TPS2552 carries the active high version |
| Fault behaviour | Latch off on the -1 parts, auto retry on the plain TPS2553 |
Electrical parameters that decide the application
| Input range | 2.5 V to 6.5 V, so it covers a 3.3 V rail as well as a 5 V one |
| On resistance | Around 70 mOhm at 5 V, with the exact figure in the electrical table for the rated current |
| Current limit accuracy | Tight enough to be set by a one percent resistor, with the min and max curves published |
| Reverse voltage | An internal comparator disables the switch when the output is driven above the input |
| Fault flag | Open drain, active low, 25 mA sink capability, deglitched |
| Thermal | Overtemperature shutdown with hysteresis, and the WSON pad is the heat path |
| Response | Constant current into a short, with the flag asserted and the switch latched off on the -1 |
Family variants and how they differ
| TPS2552 | Active high enable with the same adjustable limit |
| TPS2552-1 | Active high enable with latch off |
| TPS2553 | Active low enable with auto retry instead of latch off |
| TPS2561 | Two channels of the same idea in one body |
| TPS2051C | Fixed 0.5 A limit when a resistor is one component too many |
Points to check before this part goes on a BOM
The point of an adjustable limit is that the threshold can be set to the load rather than the load being chosen to fit the threshold. A port that must deliver 0.9 A and must never pass 1.2 A can be set exactly, where a fixed part would put 1.55 A on the same load. The cost is a resistor, its tolerance and its drift, and the resistor is part of the protection path rather than a setting that can be changed without a recheck.
The resistor range of 15 kOhm to 232 kOhm is stated for stability, not just for the limit. Outside that range the current limit loop can oscillate or the offsets in the sense amplifier dominate, so the number is a constraint on the board rather than a suggestion. A one percent resistor is what the accuracy figures assume, and a five percent part moves the limit by more than the tolerance the datasheet publishes.
Latch off is the difference between a port that recovers and a port that stays dead. On a product that must not cycle a faulting board back on, the -1 parts are correct; the switch stays off until the enable pin is toggled, which gives the host control over when the retry happens. On a port that has to recover on its own, the plain part retries, and the two behaviours are not selectable on one order code.
The reverse voltage comparator is a protection that a fixed limit switch often lacks. When the output is driven above the input, by a battery on the same node or by a second supply during a transient, the comparator turns the switch off rather than letting the body conduct backwards. That is what keeps a 3.3 V rail from being lifted by a 5 V source on a shared connector, and it works without an external diode.
The 2.5 V to 6.5 V input range makes the part usable on a 3.3 V rail, which the 5 V only members of the fixed families are not. At 3.3 V the on resistance rises and the limit accuracy is specified in the same table, so the numbers to use are the 3.3 V column and not the 5 V headline. A team that copies the 5 V figures onto a 3.3 V rail will be optimistic about both the drop and the trip point.
The fault flag can sink 25 mA, which is enough to drive an indicator directly rather than through a transistor. It is open drain and deglitched, so a short transient does not flash the indicator, and it asserts during overcurrent and overtemperature. On the latched part the flag stays asserted while the switch is off, which is how the host knows why the port is dead.
The six lead WSON has an exposed pad and that pad is the only real heat path. At a 1.7 A limit into a short the switch dissipates the input voltage times the limit, which is 8.5 W at 5 V, until the thermal circuit acts. The pad and the vias under it determine how long that takes, and a board with a pad connected to a small copper island will latch off sooner than one with a proper plane.
The current limit equations use a constant that is set by the sense amplifier, and the datasheet publishes separate minimum, nominal and maximum curves rather than a single formula. A build that needs a guaranteed floor should read the minimum curve at the chosen resistor, and a build that needs a guaranteed ceiling should read the maximum curve. Taking the nominal and adding a percentage is not the same calculation and is the commonest mistake with this part.
Latch off is a behaviour that has to be matched to the host firmware as well as to the port. Once the switch has latched, the only way back is to toggle the enable pin, and a host that never toggles it will leave a port dead until the product is power cycled. That is the correct behaviour for a backplane slot where a faulting card must not be re powered automatically, and the wrong behaviour for a USB port that is expected to recover when a user unplugs the fault. The order code is the same body either way, so the choice is made once at the bill of materials and cannot be changed in firmware.
Where this order code fits
It suits a port or a slot where the limit has to match the load rather than a catalogue value, and where a fault must leave the port off until the host decides to retry, such as an industrial backplane slot or a test fixture output. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the How to Verify a Drop in Replacement page.
Questions buyers ask
What does the -1 suffix change? The switch latches off after a fault instead of retrying automatically.
How is the limit set? By a one percent resistor from ILIM to ground, between 15 kOhm and 232 kOhm for stable operation.
Does it block reverse current? A comparator disables the switch when the output is driven above the input, which is a switch off rather than a diode drop.
Can it run on 3.3 V? Yes, the input range is 2.5 V to 6.5 V, and the 3.3 V column of the electrical table is the one to use.
What happens on overtemperature? The switch turns off and the flag asserts; on this latched version it stays off until the enable pin is cycled.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Obsolete Part Cross Reference Hub page sets out the checks that keep a substitute from failing on the bench.