Contact Us

TPS25221DRVR

Brand: Texas Instruments
Texas Instruments TPS25221DRVR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS25221DRVR — Power Management & Signal Chain | Superb Automation

TPS25221DRVR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS25221DRVR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS25221DRVR: a 5.5 V, 2 A current limited load switch in the 2 mm WSON

TPS25221DRVR is a 2.5 V to 5.5 V current limited power switch in a WSON (DRV) body of 6 pins. The DRV suffix is the 2.00 mm by 2.00 mm WSON on a 3000 piece large reel, and the marking on that reel is 1C7H. The same die also ships in the 2.90 mm by 1.60 mm SOT-23 as TPS25221DBVR, so the reel you hold decides the footprint, not the electrical behaviour.

Order code and package

TPS25221DRVRWSON (DRV), 6 pins, 3000 piece large reel, marking 1C7H, -40 to 125 C
TPS25221DRVTsame WSON body on a 250 piece small reel, marking 1C7H
TPS25221DRVRG4WSON on a 3000 piece reel, G4 suffix carried in the ordering string
TPS25221DBVRSOT-23 (DBV), 6 pins, 3000 piece large reel, marking 1B4F
TPS25221DBVTSOT-23 body on a 250 piece small reel, marking 1B4F
Finish and floor lifeNIPDAU lead finish on both bodies, MSL level 1 at 260 C, unlimited floor life out of the bag

Electrical parameters that decide the application

Input range2.5 V to 5.5 V operating, 6 V absolute maximum on IN, OUT, EN, FAULT and ILIM, 6 V maximum from IN to OUT
Continuous current2 A maximum on both bodies, the figure the comparison table gives for the DBV and DRV variants alike
Current limit window275 mA to 2.7 A set by one resistor on ILIM, accuracy as tight as 6.5 percent at 1.7 A
Published limit points20 kOhm gives 2.72 A typical, 30 kOhm gives 1.82 A, 80 kOhm gives 755 mA and 210 kOhm gives 275 mA
On resistance70 mOhm typical at 25 C on both bodies, 80 mOhm (DBV) and 92 mOhm (DRV) maximum, 110 mOhm and 122 mOhm from -40 to 125 C
Short circuit response1.5 microseconds to a hard short on OUT
Fault reportingFAULT assertions are deglitched 8 ms typical, 6 ms minimum, 12 ms maximum
Enable and timingEN threshold 0.8 V to 1.6 V, 3 ms turn-on, 0.7 ms turn-off, 0.55 ms to 0.95 ms rise at 5.5 V into 1 uF and 100 Ohm
Supply current75 uA typical with the switch enabled, 0.02 uA typical and 0.5 uA maximum with it disabled
Undervoltage lockout2.37 V to 2.47 V rising with 45 mV of hysteresis
Thermal shutdown165 C, dropping to 145 C while the part is in current limit, with 20 C of hysteresis before it retries
Recognition and ESDUL 60950 and UL 62368 recognition, 15 kV contact discharge per IEC 61000-4-2 with the external capacitance fitted

Family variants and how they differ

TPS2553the same pin out, which is why the TPS25221 is quoted as a straight second source for it
DBV against DRVidentical ratings, 2.90 mm by 1.60 mm SOT-23 against 2.00 mm by 2.00 mm WSON, and the WSON version runs cooler on the same copper
Enable polarityactive high on both bodies, so a pull down resistor is needed where the rail must stay off before the controller boots
Latch offnot fitted, the part retries after the 165 C shutdown falls back by the 20 C hysteresis
Ceiling2 A continuous on both bodies, no higher current variant in this family

Points to check before this part goes on a BOM

The current limit resistor is the only component that changes the part's job, and the transfer is not linear. The table gives 2.72 A at 20 kOhm but 1.82 A at 30 kOhm and 755 mA at 80 kOhm, so a 1.5 A target sits between two published points and has to come off the vendor curve rather than an interpolation guess. Tolerance also widens as the limit falls: the 6.5 percent figure applies at 1.7 A, and at 210 kOhm the window opens to 220 mA through 330 mA.

Heat is the second decision. At 2 A through 70 mOhm the switch burns 280 mW, and at the 122 mOhm hot figure for the DRV body that becomes 488 mW, so a board that runs the part near its ceiling has to give the WSON copper to sit on. The SOT-23 carries the same die in a smaller pad area and reaches the 165 C shutdown sooner when both are asked for 2 A in still air.

Reverse current blocking while disabled is the reason this part shows up on USB ports, set top boxes and optical socket protection. A rail that can be back fed from a charged cable holds the output down instead of pulling current backwards through the switch, and the 8 ms FAULT deglitch keeps a short cable transient from being reported to the controller as a fault.

The FAULT pin is open drain with a 0.5 uA off-state leakage and a 180 mV low level at 1 mA, so a 10 kOhm pull up to the local rail is enough and the controller sees a clean edge. Teams that move from the SOT-23 to the WSON usually keep the same ILIM resistor and change only the pad geometry.

What the reel and the BOM should say

The reel label, the box label and the ordering string have to agree on TPS25221DRVR before the part goes to a line. The G4 suffix is a separate ordering string on the same WSON body, and a line that treats the two as interchangeable will fail an incoming inspection against a drawing that names one of them. Part marking is 1C7H for the WSON and 1B4F for the SOT-23, so a mixed bin is caught visually before any electrical test.

Two components belong next to the page: the ILIM resistor and the FAULT pull up. The resistor sets the whole behaviour of the switch, and a 5 percent part in its place moves the limit outside the window the board was qualified against. The pull up only has to hold 1 mA at 180 mV, so a 10 kOhm part is ample, but it must be present or the controller never sees the fault.

Where this order code fits

It turns up in USB port and hub power, set top boxes, HDTV boards and optical socket protection, everywhere a 5 V rail has to be limited without a fuse. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Pin to Pin Cross Reference page.

Questions buyers ask

Does the DRVR drop into a TPS2553 socket? Yes. The vendor lists the TPS25221 as pin to pin with the TPS2553, so the pads and the pin out carry over. What does not carry over automatically is the ILIM resistor value and the FAULT pull up, so both are checked against the TPS25221 tables before a second source is released to a line.

Which resistor gives a 1.5 A limit? The published points bracket it rather than name it: 30 kOhm gives 1.82 A and 80 kOhm gives 755 mA, so the value comes off the vendor curve in the data sheet. A 1 percent resistor is the practical choice because the limit window already opens up at the low end of the range.

Is the WSON available in small reels for a pilot run? Yes, TPS25221DRVT is the same WSON body on a 250 piece small reel, and the SOT-23 counterpart DBVT is also offered at 250 pieces. The 3000 piece large reel is DRVR.

What happens when the load is shorted? The internal FET drops into constant current mode within 1.5 microseconds, holds the load at the programmed limit, and FAULT asserts after the 8 ms deglitch. If the condition persists the junction climbs to the 145 C current limit shutdown and the part retries after the 20 C hysteresis.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the BOM Shortage Recovery page sets out the checks that keep a substitute from failing on the bench.