TPS22946YZPR
Product Specifications
TPS22946YZPR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS22946YZPR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS22946YZPR ultra low power current limited load switch with selectable limit and auto restart in the 6 bump DSBGA
The TPS22946YZPR is a current limited load switch built for a very small standby current: about one microamp quiescent at 1.8 V, a shutdown current below a microamp, and a current limit that is selected by the state of a pin rather than fixed by the order code. It sits in a six bump wafer level package 1.4 by 0.9 mm, and it carries an auto restart and a five second time out that the simpler limited switches do not.
The limit selection is the feature that makes it flexible. A high on the CL pin sets 155 mA, a low sets 70 mA and a floating pin sets 30 mA, so one part number covers three load classes. When the switch is enabled it allows a 435 mA inrush window for 8 ms so an LDO or a capacitor bank can charge, then settles to the selected limit. A constant current condition lasting 10 ms turns the switch off and pulls the flag low, and the part restarts after 70 ms if the enable is still active. A fault that persists for five seconds latches the part off until the enable is cycled.
Key parameters taken from the TPS22946YZPR document
| Input range | 1.62 V to 5.5 V |
| On resistance at 5.5 V | 300 mOhm typical and 0.4 Ohm maximum |
| On resistance at 3.3 V | 400 mOhm typical and 0.5 Ohm maximum |
| On resistance at 2.5 V | 500 mOhm typical and 0.6 Ohm maximum |
| On resistance at 1.8 V | 600 mOhm typical and 0.65 Ohm maximum over the full range |
| Quiescent current | 1 microamp typical and 1.5 microamp maximum at 5 V, 1 microamp typical and 1.3 microamp maximum at 3.3 V, and 1 microamp typical at 1.8 V |
| Shutdown current | 0.1 microamp typical and 1 microamp maximum with the enable low |
| Current limit selection | 155 mA with CL high, 70 mA with CL low and 30 mA with CL floating |
| Inrush window | 435 mA for 8 ms after the switch is enabled, so a load capacitor or an LDO can charge without a false fault |
| Blanking window | 10 ms of constant current before the switch opens and the flag asserts |
| Auto restart | 70 ms after a fault clears, provided the enable is still active |
| Overcurrent time out | Five seconds of continuous fault latches the switch off until the enable is cycled |
| Thermal shutdown | 135 C, with automatic recovery once the junction cools |
| Body and packing | DSBGA YZP 6 bumps, 1.4 by 0.9 mm, 3000 pieces on a large reel, minus 40 to plus 85 C |
| ESD | 6 kV human body model and 1 kV charged device model, which is higher than the usual 2 kV floor |
The table above is read from the vendor document, not from a distributor summary. Where a window is printed, the window is what a production test should use, and the typical value is only a starting point for the first article.
Where the numbers matter in a real build
The three limit levels come from one pin and that pin has three states, which is a trap for a board that drives it from a GPIO with a weak pull. A floating CL pin gives the 30 mA level, a driven low gives 70 mA and a driven high gives 155 mA. If the GPIO is high impedance during reset, the part starts at 30 mA and a load that needs 100 mA never comes up, which looks like a dead port. The fix is a defined pull on the CL pin, and the choice of pull decides the default level before the firmware runs.
The 8 ms inrush window at 435 mA is what distinguishes this part from a plain limited switch. An LDO with a 10 microfarad output capacitor draws a surge at start up that would trip a 30 mA limit immediately, and the part deliberately allows a higher current for a fixed time so that the downstream regulator can establish its output. After 8 ms the limit drops to the selected level, and a load that is still drawing more than that starts the 10 ms blanking timer. The two windows are sequential, and a load that needs more than 8 ms to charge will be treated as a fault even though the current is legitimate.
The restart and time out behaviour is a three stage policy inside the part. A fault of 10 ms opens the switch, the part waits 70 ms and tries again, and if the fault is still there after five seconds of this cycle it stops trying and latches off until the enable is cycled. That is a sensible compromise for a port that may see a transient short, and it is also a behaviour a host has to understand, because a port that is being retried every 70 ms looks alive to a voltage monitor while it is actually in a fault loop.
The one microamp quiescent current is the reason the part exists, and it is worth putting in perspective. A wearable that sleeps at 20 microamps has this switch as five per cent of the budget, which is acceptable, and a product that sleeps at 2 microamps cannot use it at all. The shutdown current below a microamp is the figure for the off state, and the difference between the two is what the product pays for leaving the rail connected. The 6 kV human body model rating is unusually high for a part this size and is useful on a connector facing rail.
- The state of the CL pin during reset, because a floating pin selects the lowest limit and can make a good load look dead.
- The charge time of the downstream capacitance against the 8 ms inrush window at 435 mA.
- The blanking and restart timing as a policy, since the part retries every 70 ms and latches after five seconds.
- The quiescent current against the sleep budget, one microamp is small but not zero.
- The on resistance at 1.8 V, 0.65 Ohm maximum, which sets the drop at the selected limit.
- The thermal path in a six bump package, since there is no pad to spread the dissipation.
Which projects this part fits
This part fits fingerprint module protection, portable consumer electronics and mobile phones with a sensor rail that has to be current limited, smartphones and notebooks with a peripheral port, GPS devices, and any product where the standby current is measured in microamps and the load is a small module that can fail short. The three selectable limits mean one part number can serve several ports with different load classes.
Questions that come up before a purchase order is released
How do I get the 30 mA level?
Leave the CL pin floating. That is the lowest of the three levels and it is the state the part defaults to when nothing drives the pin, which is why a board should either drive it deliberately or fit a resistor that sets the intended level.
What is the 435 mA inrush window for?
It lets a downstream LDO or a capacitor bank charge for 8 ms after the switch is enabled without tripping the selected limit. Without it, a 30 mA port could never start a load with any capacitance. The window is fixed and it starts when the switch is enabled, not when the current first exceeds the limit.
Does the part really latch off after five seconds?
Yes. If the fault persists through the restart cycles for five seconds, the switch stops retrying and stays off until the enable is cycled. That protects the board from a permanent short while still allowing a transient to clear on its own.
Is the flag open drain?
It is, and it asserts on current limit, undervoltage and thermal shutdown. The pull up has to go to a rail that is present when the fault occurs, which in most products is the input rail rather than the switched one.
Can this part replace a fixed limit switch without a board change?
Only if the CL pin is handled. The footprint is a six bump wafer level package, so a board built for a five pin SC-70 cannot take it without a new land pattern. Within the same family, the limit level is the only difference and the pin out is identical.
How SUPERB handles this line
We supply the TPS22946YZPR on original 3000 piece reels with the date code recorded, and we can supply the fixed limit members of the same family when a board does not need the selectable pin. The power management cross reference page lists the limited switches by level, restart policy and body, BOM shortage recovery covers the case where the wafer level body is short and a leaded alternative has to be qualified, and kitting service is how we deliver these parts against a portable product build.