The TPS22917LDBVR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS22917LDBVR 2 A load switch with adjustable rise and fall times and an active low enable in the 6 pin SOT-23
The TPS22917LDBVR is the active low member of the TPS22917 family: a single channel load switch rated 2 A from 1 V to 5.5 V, with an on resistance of 80 mOhm at 5 V, an external capacitor that sets the turn on ramp, and a pin that sets the output discharge. It is the version for a system where the enable signal is low true and where the rise time has to be tuned to the load rather than picked from two fixed options.
The family is the answer to a problem the fixed timing parts cannot solve: the inrush a rail can tolerate depends on the capacitor behind it, and that changes between products. A capacitor on the CT pin stretches the ramp from about 100 microseconds with the pin open to milliseconds with a nanofarad fitted, and the QOD pin sets the fall by connecting the internal discharge resistor or leaving it open. The enable is active low here, so the rail comes up when the controlling pin is pulled down, and the smart pull down holds the pin at a defined level until the system drives it.
Key parameters taken from the TPS22917LDBVR document
| Input range | 1 V to 5.5 V |
| Maximum continuous current | 2 A |
| On resistance at 5 V | 80 mOhm typical and 100 mOhm maximum at 25 C, 120 mOhm over minus 40 to 85 C, 130 mOhm to 105 C and 140 mOhm to 125 C |
| On resistance at 3.6 V | 90 mOhm typical and 110 mOhm maximum at 25 C, 140 mOhm over the standard range |
| On resistance at 1.8 V | 120 mOhm typical and 150 mOhm maximum at 25 C, 175 mOhm over minus 40 to 85 C |
| On resistance at 1 V | 220 mOhm typical and 300 mOhm maximum at 25 C, 350 mOhm over the standard range |
| Quiescent current | 0.5 microamp typical, 1 microamp maximum to 85 C and 1.2 microamp to 125 C |
| Shutdown current | 10 nA typical and 100 nA maximum on the active high member, with separate and higher rows printed for the L member |
| Turn on time | About 100 microseconds at 5 V with the CT pin open, and about 4000 microseconds with a 1000 pF capacitor fitted |
| Fall time control | The QOD pin connected to the output gives the fastest fall through the internal 150 Ohm resistor, and leaving it open gives the slowest |
| Reverse current blocking | Always active, trips at about minus 500 mA with a 10 microsecond response and releases at 25 mV |
| Reverse leakage | 1 microamp maximum while blocking, which is higher than the sibling family and worth counting |
| Enable | Active low on this member, with a 750 kOhm smart pull down that holds the pin until the system drives it |
| Body and packing | SOT-23 DBV 6 pins, 3000 pieces on a large reel, NIPDAU finish, moisture level 1 with unlimited floor life, minus 45 to plus 125 C in the addendum |
The table above is read from the vendor document, not from a distributor summary. Where a window is printed, the window is what a production test should use, and the typical value is only a starting point for the first article.
Where the numbers matter in a real build
The adjustable ramp is the feature that makes this part usable across a product family. The same board with a different CT capacitor can serve a rail with 10 microfarad and a rail with 470 microfarad, and the inrush stays inside what the upstream supply can deliver. The vendor prints two endpoints, about 100 microseconds with the pin open and about 4 ms with 1000 pF at 5 V, which means the capacitor scales the ramp roughly linearly in that window. A product that copies the circuit from a board with a different load capacitor and does not change CT inherits an inrush it did not plan for.
The QOD pin is the second adjustable feature and it is easy to misuse. Connected to the output, the internal 150 Ohm resistor discharges the rail quickly, which is what a rail that feeds a processor needs so that the next power up starts from zero. Left open, the rail falls at the rate the load draws, which can take seconds on a light load. A board that ties QOD to the output on a rail with a large capacitor and no series resistance gets a discharge current of 22 mA per volt, which the switch handles, but the same pin on a rail that is back fed from another supply fights that supply and the reverse blocking comparator sees the result.
The enable polarity is the difference from the active high member, and it has a consequence that shows up in reset. On this part the switch is on when the pin is low, so a processor that drives its pins low during reset turns the rail on at the worst possible moment. The smart pull down helps only when the pin is floating, not when it is actively driven low. A board that uses the L member has to invert the control signal from the reset state, or accept that the rail comes up before the firmware is ready. That is a system level decision, and it is the reason the active high member exists in the same family.
The temperature range is broader than most of this family, and the on resistance rows show why the current rating should be read at the temperature the product runs. At 125 C the 5 V figure is 140 mOhm maximum against 100 mOhm at 25 C, so the same 2 A load dissipates 560 mW instead of 400 mW. In a six pin SOT-23 with no thermal pad, that is the difference between a comfortable junction and a part that derates its own load. The vendor's 1.2 microamp quiescent figure at 125 C is the same story in a smaller number.
- The CT capacitor, because the ramp and the inrush scale with it and the default with the pin open is the fastest option.
- The QOD connection, which decides how fast the rail collapses and whether it fights a back feed.
- The enable polarity, since the active low member turns on when a processor pin is low during reset.
- The shutdown current rows for the L member specifically, which are printed separately and are higher than the active high part.
- The on resistance at the hot corner, 140 mOhm maximum at 125 C, for any load above an amp.
- Reverse blocking leakage of 1 microamp maximum if the off state budget is measured in microamps.
Which projects this part fits
This part fits industrial systems with a card rail that has to come up in a defined ramp, set top boxes and point of sale terminals where the enable signal is low true by legacy, blood glucose meters and portable instruments with a 1.8 V analog rail, and any board where the rise time has to be tuned after the load capacitor is known. The SOT-23 body is also the choice where a production line wants to inspect solder joints on a leaded package rather than a wafer level part.
Questions that come up before a purchase order is released
What value of CT should I start with?
Start with the pin open, measure the inrush into the real load, and add capacitance until the peak is inside what the upstream supply allows. The vendor prints the two endpoints, about 100 microseconds open and about 4 ms with 1000 pF, so a first prototype can be tuned in two passes rather than by calculation.
Is the enable really active low?
Yes on the L member. The switch conducts when the ON pin is pulled low and turns off when it is driven high, which is the reverse of the active high part in the same family. The order code is the only difference and the two are not interchangeable without checking the controlling logic.
What does the QOD pin do if left open?
It disconnects the internal 150 Ohm discharge resistor, so the output falls only as fast as the load discharges it. On a rail with a light load that can be seconds, and any reset sequence that expects the rail to be at zero has to wait or to add its own discharge.
Why is the reverse leakage 1 microamp here when the sibling family quotes 300 nA?
Because the blocking circuit is a different one and the vendor prints a looser maximum. It matters only in a product whose off state current is measured in microamps, which is exactly the case where this part is used, so the number should be in the budget rather than assumed away.
Can the part be used with the input above the enable rail?
The enable is referenced to the input supply and the thresholds are printed against it, so the controlling signal has to be compatible with the rail being switched. A 1.2 V logic signal driving a 5 V rail has to be checked against the electrical table, and in most cases needs a level shift.
How SUPERB handles this line
We supply the TPS22917LDBVR on original 3000 piece reels with the marking and date code recorded, and we can supply the active high member of the same family when a board changes its logic sense without changing its footprint. The power management cross reference page lists the load switches by polarity, timing and body, BOM shortage recovery covers the case where one polarity is short and the board has to be reworked around the other, and kitting service is how we deliver these switches with the rest of a build.