TMP709AIDBVR
Product Specifications
TMP709AIDBVR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TMP709AIDBVR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TMP709AIDBVR: a thermostat that is set by one resistor
TMP709AIDBVR is a temperature switch, not a temperature sensor. It compares the die temperature against a threshold set by a single external resistor, and it asserts an open drain output when the threshold is crossed. There is no bus, no register and no address, and the part needs no firmware to work.
That makes it the right answer for a protection function that must survive a hung processor. A fan failure, a blocked filter, a charger that will not stop charging: all of those can be handled by a switch that pulls a shutdown line low without any code running. The sensor half of the part is a trimmed reference and a comparator, and the accuracy of the trip point is 0.5 degrees typical and 3 degrees maximum between 60 and 100 degrees.
The numbers below come from SBOS583B, revised December 2016, and from the package option addendum. They cover the set point arithmetic, the two hysteresis settings, the output stage, the supply current and the thermal resistance of the 5-pin SOT-23 body, plus the worked examples of choosing a resistor from the E96 series.
Setting the trip point with one resistor
The set point resistor goes from the SET pin to ground, and the document gives the relation as RSET in kilohms equals 0.0012 times T squared minus 0.9308 times T plus 96.147, with T in degrees Celsius. The curve is not linear, so the resistor falls steeply as the threshold rises: 44.6 k for 60 degrees, 33.1 k for 75, 25.7 k for 85, 15.1 k for 100 and 1.73 k for 120.
The useful consequence is that a 1 percent resistor gives a trip point that is closer than the accuracy of the part. At 85 degrees the slope is 0.727 k per degree, so the nearest E96 value of 25.5 k sets a threshold 0.27 degrees above the calculated point, and 26.1 k sets it 0.55 degrees below. At 100 degrees the slope is 0.691 k per degree and the nearest E96 value of 15.0 k lands within 0.1 degrees. The resistor tolerance dominates once the value is chosen, which is why the document asks for 1 percent and why a 5 percent part is not a shortcut.
Above about 122 degrees the calculated resistance reaches zero, so the highest practical set point is with the SET pin tied to ground. The part itself is specified up to 125 degrees, and the addendum prints an operating window of minus 40 to plus 125. A board that needs a trip point at the very top of that window should confirm the behaviour with the vendor rather than assume the formula continues.
| Function | resistor programmable temperature switch |
| Threshold accuracy | 0.5 degrees typical, 3 degrees maximum from 60 to 100 degrees |
| Set point element | one 1 percent resistor from SET to ground |
| Set point equation | RSET in k equals 0.0012 T squared minus 0.9308 T plus 96.147 |
| Hysteresis | 2 degrees with HYST at ground, 10 degrees with HYST at supply |
| Output | open drain, active low, 12 mA sink at 0.3 V |
| Output leakage | 1 microamp maximum with the output high |
| Supply range | 2.7 V to 5.5 V |
| Supply current | 40 microamps typical, 55 maximum at 5 V |
| Reset behaviour | specified at 0.8 V supply, so the output is defined during a brownout |
| Package | SOT-23-5, DBV, 2.90 mm by 1.60 mm |
| Thermal resistance | 217.9 degrees per watt junction to ambient |
| Self heating at 40 microamps | 0.048 degrees at 5.5 V, computed from the printed thermal resistance |
| Carrier | 3000 pieces on a large reel, marking SBJ |
| Moisture level | level 2 at 260 degrees, one year floor life |
| Op temperature | minus 40 to plus 125 on the addendum row |
Hysteresis and the oscillation problem
A comparator with no hysteresis chatters when the temperature sits on the threshold. The output switches, the load changes, the die temperature moves, the output switches back, and the result is a relay or a fan controller that buzzes. The TMP709 fixes that with a pin: tie HYST to ground for 2 degrees of hysteresis, tie it to the supply for 10 degrees.
Two degrees suits a board that is temperature controlled and needs a tight window. Ten degrees suits a fan or a heater, where a wide window means fewer switching cycles and longer relay life. The pin must be tied to one rail or the other; the document warns that an intermediate voltage can cause abnormal supply current or a malfunction, which rules out leaving it floating on a board where the pin is not driven.
After the output trips, the hysteresis block raises the reference so that the part does not untrip until the temperature has fallen by the hysteresis amount. That is the behaviour a mechanical thermostat provides with a bimetal disc, and it is the reason this part is described as a replacement for one.
The output stage and what it can drive
The output is an open drain NFET that sinks 12 milliamps at 0.3 V. That is enough for an optocoupler, a relay driver transistor, a fan controller input or a supervisor reset line, and it is not enough for a relay coil or a fan directly. The pull-up sets the current when the output is low, and the document recommends a value above 10 k to keep the internal dissipation down.
The active low polarity matches the way most shutdown and enable pins work, so the sensor can pull a regulator enable low without an inverter. On a board with several protection sources the outputs can be wired in a wired OR arrangement, with one pull-up and any source able to assert the line. That is the standard way to combine a thermal trip, a current trip and a watchdog into one shutdown.
The reset behaviour is specified at a supply of 0.8 V, which means the output state is defined while the rail is still coming up. On a hot plug event that matters: the shutdown line must not float during the ramp, or the load may start before the protection is alive.
Thermal coupling and self heating
The part measures its own die, so the only thing that matters is how well the die is coupled to the object being protected. The document is direct about it: good thermal contact between the package and the monitored device is required, and the self heating term is the dissipation times 217.9 degrees per watt. At 40 microamps and 5.5 V the dissipation is 220 microwatts, which is 0.048 degrees, so self heating is negligible as long as the output current is kept small.
The coupling is the real mechanical problem. A SOT-23 sitting 5 mm from a power device on a 1 oz board sees a temperature that is 10 to 20 degrees below the device, and a trip point set for the device temperature will fire late. The common fix is a copper island under the package connected to the device tab, or a placement close to the heat source with the set point adjusted for the gradient.
For a charger or a motor driver the part is often placed on the same copper as the device tab, with the SET resistor nearby and away from the hot copper so that its value does not drift. A 1 percent resistor with a 100 ppm per degree tempco moves by 0.1 percent over 10 degrees, which is 0.14 degrees of trip point at 85 degrees, so the resistor drift is a second order term compared with the coupling error.
Where a switch beats a sensor
The document lists computers, servers, industrial and medical equipment, storage area networks and automotive. The common thread is a protection function that has to work without software. A medical device with a thermal hazard in its risk file, a server with a fan that can seize, a charger that can fail short: all of them need a trip that does not depend on a bus transaction completing.
In our builds the part appears on power boards and on battery chargers, usually wired into the enable chain of a regulator. It also appears as a second line of defence behind a digital sensor: the digital part reports the temperature for logging and derating, and the switch handles the case where the digital part or its bus has failed. That arrangement is easy to justify to an auditor, which is why it is common in medical equipment. Our medical device component sourcing page covers the parts we keep for that class of build.
The alternative is a comparator and a thermistor, which costs more parts, more board area and a calibration step. The switch replaces that with one resistor and no calibration, and it holds its trip point over the full supply range because the reference is internal. The one stop BOM sourcing route consolidates the resistor and the switch onto one line.
Three questions buyers ask about this string
Can the trip point be changed without a board change? Only by changing the resistor. The part has no register and no digital interface, which is the point of it.
What happens if the SET resistor is missing? The SET pin floats and the behaviour is undefined. Fit the resistor even on a build that does not use the output, because the input is not internally biased.
Is the 3 degree maximum error too wide for a protection function? It is wide compared with a digital sensor and it is narrow compared with the margin a protection function normally needs. A trip point set 15 degrees above the maximum operating temperature of the load will not fire early even at the worst case error, and the PCBA test coverage strategy page describes how we verify the trip in production.