SN65HVD1794DR
Product Specifications
SN65HVD1794DR
Texas Instruments — Power Management & Signal Chain
Product Overview
The SN65HVD1794DR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
SN65HVD1794DR: half duplex RS-485 transceiver that survives 70 V on the bus pins and can invert a crossed pair in software
SN65HVD1794DR is a differential driver and receiver on one 5 V supply, with bus pin fault protection beyond 70 V and a cable invert input that swaps the pair when the installation is wired backwards in a SOIC body of 8 pins. It is a half duplex two wire part at 115 kbps over cable runs up to 1500 m, with unit loading that allows 256 nodes, a common mode window from minus 20 V to plus 25 V, 16 kV of human body model protection on the bus pins, a quiescent current of 5 mA, and a fail safe receiver that holds a defined output on an open, shorted or idle bus. The invert pin is the feature that separates it from a plain transceiver: a logic high on that pin flips the polarity of the bus port, so a pair installed the wrong way round is corrected from the controller instead of from a screwdriver.
Order code and package
| SN65HVD1794DR | SOIC D body, 8 pins, 2500 pieces on a large reel, Active in the addendum dated 10 August 2026, NIPDAU finish, moisture level 1 with no floor life limit, marking VP1794, minus 40 to plus 105 degrees |
| SN65HVD1794D | the same body in a 75 piece tube, which is the row a small build or a sample order comes from, and the row to quote when a customer asks for ten pieces and the reel minimum would double the price |
| SN65HVD1795 and SN65HVD1796 | the other two members of the same family, both printed as PREVIEW in the selection table: the 1795 is 1 Mbps over 150 m with 256 nodes and the 1796 is 10 Mbps over 50 m with 64 nodes. A PREVIEW status means the part is not orderable yet, so a bill of materials that names one of them needs a plan |
| SN65HVD1781 | the 3.3 V relative with the same fault protection idea, which is the part to look at when the logic rail is 3.3 V rather than 5 V and the bus still has to survive a miswire |
| Against the plain family | an SN75176 class part has no fault protection beyond the supply rails and no invert pin, so the two features that make this device worth its price are exactly the two that a plain part does not have |
Electrical parameters that decide the application
| Signalling rate | 115 kbps on this member, which is the rate that 1500 m of cable supports, and the same body is offered at 1 Mbps over 150 m and 10 Mbps over 50 m in the two preview members |
| Fault protection | more than plus or minus 70 V on the bus pins, which is the number that survives a direct short to a 48 V supply, a miswire to a 24 V loop and a connector failure on a live cabinet |
| Common mode range | minus 20 V to plus 25 V, more than double the minus 7 V to plus 12 V the RS-485 standard asks for, which is what keeps a receiver working on a long run with a large ground potential difference |
| Unit loading | up to 256 nodes on one bus, so a multi drop installation does not need a repeater until it passes that count |
| Driver differential output | 1.5 V minimum into a 54 ohm load at ambient up to 105 degrees, and 1.4 V minimum up to 85 degrees, both above the 1.5 V the standard asks for at the colder limit and the reason the temperature column matters here |
| Driver propagation | 0.8 us typical and 2 us maximum into a 54 ohm load with 50 pF, which is slow by modern standards and exactly right for 115 kbps over 1500 m |
| Receiver propagation | 100 ns typical and 200 ns maximum into a 15 pF load, with a pulse skew of 70 ns, so the receiver is not the limiting element at this data rate |
| Quiescent current | 5 mA during operation, which is low for a fault protected part and is the figure that decides whether the port can stay powered in a battery backed cabinet |
| ESD | plus or minus 16 kV human body model on the bus pins, measured to the JEDEC specification, which is the level a service technician generates handling a cable on a dry day |
| Fail safe | the receiver holds a defined high output on an open circuit, a shorted pair and an idle bus, so a controller does not read a random start bit when the cable is unplugged |
| Power sequencing | glitch free on power up and power down, which matters when the transceiver and the controller are on separate rails and one comes up before the other |
| Temperature | minus 40 to plus 105 degrees, seven degrees beyond the 85 degree ceiling of the plain industrial parts, and the addendum prints that range on every row of this string |
Family variants and how they differ
| 1794 against 1795 | same fault protection and same invert function, 115 kbps against 1 Mbps, and 1500 m against 150 m of cable. The slower member is the one for a long field bus, the faster one for a cabinet internal link |
| 1794 against 1796 | the 1796 is 10 Mbps and drops to 64 nodes and 50 m, so it is a different bus rather than a faster version of the same one. Mixing a 1796 into a 256 node trunk is the kind of substitution that works on the bench and fails in the field |
| Against a 3.3 V part | the SN65HVD1781 carries the same protection at 3.3 V, and the SN65HVD1477 family adds full duplex and 50 Mbps at 3.3 V with a wider temperature range, at a higher price |
| Against an isolated transceiver | an ISO3080 class part puts a barrier inside the package, which removes the common mode problem entirely and costs four to six times as much. A long run between two buildings usually needs the isolated part, and a cabinet internal run does not |
| Against a protected discrete front end | a TVS array plus a plain transceiver reaches a similar survival voltage with three more parts and no invert function, and the residual current path through the TVS is what the integrated protection avoids |
Points to check before this part goes on a BOM
The fault protection is the whole point of the part and it has to be read as a survival rating rather than an operating window. The receiver works from minus 20 V to plus 25 V of common mode; the bus pins survive 70 V. Between those two numbers sits the region where the part is not damaged and also not receiving, which is the correct behaviour during a fault and is often mistaken for a failed unit on a test bench.
The invert pin changes the wiring problem into a firmware problem, and that changes the cost of the whole installation. On a 1500 m run with forty nodes, a crossed pair used to mean a site visit; with this part the controller can try both polarities and keep the one that produces valid frames. What it cannot do is invert a single node on a shared bus, because the other nodes still see the original polarity, so the function is for a point to point or a two node link.
The 1.5 V differential output at 105 degrees is 100 mV above the 1.4 V printed for the 85 degree limit, and that small gap is what a 120 ohm terminated bus with thirty two unit loads sits inside. A bus built with 96 ohm cable and no termination draws more current and produces less differential voltage, and the margin this part carries is what absorbs the difference.
The 5 mA quiescent current is low for a fault protected device because the protection is a clamp rather than a series element. A part that inserts a resistor in series with the bus pin to survive a fault also drops signal amplitude and adds a temperature dependent term, and the clamp approach avoids both at the cost of a survival behaviour that depends on the external current being limited by the source impedance.
The fail safe receiver is not the same as a fail safe bias network. This part holds a defined output with the bus open, shorted or idle, which removes the need for the two bias resistors a plain transceiver needs on an idle bus. Teams migrating from an SN75176 usually delete those resistors, and the ones that keep them find the bus loaded slightly harder and the differential swing slightly smaller, which shows up only at the far end of a long run.
The PREVIEW status of the two siblings is worth saying out loud at the quoting stage. A customer who copied the 1796 into a bill of materials because it is the fast member of the family will not get silicon on a normal lead time, and the honest move is to quote the 1794 with a note that the faster member is not released, rather than to accept the order and wait.
Where a 70 V survival rating is needed
The number comes from the faults that happen in a real cabinet: a bus wire shorted to a 24 V or 48 V supply during maintenance, a connector inserted one pin off, a cable crushed against a metal edge, a tool dropped across the terminals. All of them put a supply rail on a bus pin that was specified for minus 7 V to plus 12 V, and a plain transceiver dies in that event while this one keeps working.
What the part does not do is protect the rest of the board. The fault current still flows through the pin, and if the source can deliver more than the clamp path absorbs for the length of the event, the energy has to go somewhere. The datasheet section on the bus pin protection describes the clamp behaviour; a cabinet where a bus can be shorted to a supply indefinitely is a case for a series resistor or a fuse as well, and that decision belongs to the customer's electrical requirement rather than to the transceiver.
What the order code decides
The string reads SN65HVD1794 for the device, D for the SOIC body and R for a large reel of 2500. The same body in a 75 piece tube is the plain D string. Nothing in the code selects the data rate or the protection level, because this member has one of each. The other two members carry different numbers rather than different suffixes, which is why a substitution between them is a substitution of part number and never of a reel letter.
Where this order code fits
RS-485 and RS-422 networks are the stated application, and the practical ones are utility metering, process control, building automation and any cabinet where a bus wire can meet a supply rail during service. Teams comparing it with a neighbouring part start from our CAN Bus Transceiver Selection page, and teams replacing a part that has gone end of life start from the Pin to Pin Cross Reference page.
Questions buyers ask
Can the invert pin fix a crossed pair in the field? Yes for a point to point or two node link, by driving the invert input high from the controller. On a shared bus it only flips this node and leaves the others, so it is not a repair for a trunk.
Is 115 kbps enough for a modern installation? Over 1500 m of cable it is the rate the cable supports. A shorter run can use the 1 Mbps or 10 Mbps members, which are printed as PREVIEW and therefore not orderable yet.
Does the receiver work with the bus unplugged? It holds a defined output on an open, shorted or idle bus, so the controller reads a known state rather than noise.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the How to Verify a Drop in Replacement page sets out the checks that keep a substitute from failing on the bench.