Contact Us

ISO7731FDWR

Brand: Texas Instruments
Texas Instruments ISO7731FDWR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

ISO7731FDWR — Power Management & Signal Chain | Superb Automation

ISO7731FDWR

Texas Instruments — Power Management & Signal Chain

Product Overview

The ISO7731FDWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

ISO7731FDWR: Three Channels, Default Low, 100 Mbps, Minus 55 to 125 Degrees

ISO7731FDWR is a triple-channel reinforced digital isolator in a SOIC body of 16 pins. Two channels run forward and one runs back, the default output is low, and the family carries a 100 Mbps rate with a 5000 VRMS barrier and an ambient range that starts at minus 55 degrees.

Order code and package

Ordering stringISO7731FDWR
PackageSOIC, 16 pins, DW body
CarrierTape and reel, 330 mm reel, 16.4 mm tape, pocket 10.75 by 10.7 by 2.7 mm, Q1, quantity printed as 2000 on the DW rows
Alternative packageDBQ 16, the QSOP body, as ISO7731FDBQR
Supplies2.25 V to 5.5 V, each side independent
Temperature rangeminus 55 to plus 125 degrees Celsius
Channel directionTwo forward, one reverse
Default stateOutput low, the F suffix, the plain string defaults high

Electrical parameters that decide the application

Data rate100 Mbps
Isolation ratingUp to 5000 VRMS per UL 1577
Working voltage1500 VRMS, projected lifetime above 30 years
Surge isolation capabilityUp to 12.8 kV
Transient isolation voltage2121 VPK repetitive peak on the DW body, 566 VPK on the DBQ body
Common-mode transient immunityplus or minus 100 kV per microsecond typical
Propagation delay11 ns typical at 5 V supplies
Supply current1.5 mA per channel typical at 1 Mbps
Level translation2.25 V to 5.5 V on either side
Clearance and creepageAbove 8 mm on the DW body, above 3.7 mm on the DBQ body
System-level ESDPlus or minus 8 kV IEC 61000-4-2 contact across the barrier
Enable pinsPer-side enable, outputs to high impedance

Family variants and how they differ

ISO7730Three forward channels, default high
ISO7730FThree forward channels, default low
ISO7731Two forward and one reverse, default high
ISO7731FTwo forward and one reverse, default low, the part on this page
Package splitDW 16 gives 2121 VPK repetitive peak and above 8 mm clearance, DBQ 16 gives 566 VPK and above 3.7 mm
Qualified versionsISO7730-Q1 and ISO7731-Q1 are the automotive members
Generation noteThe ISO674x family is the quad-channel equivalent at 50 Mbps with a 1500 VRMS working voltage and a narrower temperature range

Points to check before this part goes on a BOM

The F suffix is a safety choice, not a preference.A low default means that an unpowered input side presents a logic low to whatever is behind the isolator. If that signal drives a relay, a brake or a gate, the low state has to be the de-energised one, and the part is chosen so that the failure mode matches the mechanical state.

100 Mbps needs a clock, not a UART.At 100 Mbps the unit interval is 10 ns, and the 11 ns typical delay is longer than one bit. The rate is useful for a serial stream where the delay is constant, such as an SPI clock at 50 MHz, and not for a loop that expects the answer inside the same bit.

Minus 55 degrees is unusual and it is the reason to pick this family.Most digital isolators start at minus 40. This one is specified from minus 55 to plus 125, which covers cold-start equipment on a mast or in an outdoor cabinet in a northern winter, where the board is at ambient until the heater comes on.

The two packages are not interchangeable on isolation.The DBQ body carries 566 VPK repetitive peak and 3.7 mm of clearance, the DW body 2121 VPK and 8 mm. A part chosen for a 1000 V working bus cannot be moved to the smaller body later without reopening the insulation question.

12.8 kV surge is a barrier figure.It describes what the insulation survives in a surge test. The clearance around the part on the board, and the creepage across the solder mask, are what the system test actually stresses.

Quantity column in the addendum drifts.The DW rows in this revision print 2000 against the 330 mm reel, and several rows print the quantity one line above the string it belongs to. Confirm the piece count on the reel label for a production order rather than reading the column across.

Three channels in a two and one split

Two forward and one reverse is the shape of a isolated SPI link: clock and data out, data back, with the chip select handled on the controller side. The same shape fits an isolated UART plus a direction signal, which is why this member outsells the four-forward part in instrumentation.

The reverse channel is independent of the forward pair, so its delay does not have to match theirs. Where a matched pair matters, the channel-to-channel skew figure in the switching table covers the same-direction channels only.

What 1.5 mA per channel at 1 Mbps means for a loop-powered device

A 4 to 20 mA transmitter has about 3.5 mA of budget for the whole circuit and the loop current has to stay above 3.8 mA at the low end. Three channels at 1.5 mA each would consume the entire budget, so a loop-powered device uses the low-power family instead, and this part belongs on the isolated side of a separately powered module.

That is the trade the family forces: 100 Mbps and 1.5 mA per channel here, or 4 Mbps and microamps in the ISO7041 class, and the choice follows from where the power comes from.

How three channels behave when one side loses power

With the F string, all three outputs go low when side 1 loses power. Two of them face forward and one faces back, so the low state appears on the two forward lines at the far end and on the one reverse line at the controller. Each of those three receivers has to treat a low as the safe state, or the failure mode produces a command rather than a shutdown.

The default state is held by the barrier rather than by the input, which is why it survives a supply that collapses slowly. If the two supplies ramp at very different rates, there is a window in which one side is live and the other is not, and during that window the outputs are in their default state. The length of that window should be checked against the far-end startup sequence.

Where this order code fits

Cold-climate outdoor equipment, isolated SPI links and multi-axis drive interfaces use this part where three signals cross the barrier and the cabinet is specified below minus 40 degrees. Teams comparing it with a neighbouring part start from our Pin to Pin Cross Reference page, and teams replacing a part that has gone end of life start from the BOM Shortage Recovery page.

Questions buyers ask

Does the F suffix change the pinout? No. The F string changes the default output state only, from high to low on loss of input power or signal. The footprint and the pin functions are the same.

Can ISO7731FDWR drive a 50 MHz SPI clock? It can carry 100 Mbps, and the 11 ns typical delay is constant, so the clock and data arrive with a fixed offset. What has to be checked is the round-trip timing through the reverse channel for the data coming back.

Why does the DBQ version have a lower isolation figure? The smaller body has less clearance and creepage, so the insulation table prints 566 VPK repetitive peak and 3.7 mm against it, against 2121 VPK and 8 mm on the DW body.

Is the part rated for minus 55 degrees in both packages? The temperature range is a device specification and is printed as minus 55 to plus 125 for the family. The package choice affects the isolation figures, not the ambient window.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the How to Verify a Drop in Replacement page sets out the checks that keep a substitute from failing on the bench.