Product Specifications

ISO7731DWR — Power Management & Signal Chain | Superb Automation

ISO7731DWR

Texas Instruments — Power Management & Signal Chain

Product Overview

The ISO7731DWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

ISO7731DWR: The Default-High Version of the Same Three-Channel Barrier

ISO7731DWR is a triple-channel reinforced digital isolator in a SOIC body of 16 pins. It is the plain string against the F version on the same die: two forward channels and one reverse, 100 Mbps, 5000 VRMS, but the outputs sit high when the input side loses power or signal.

Order code and package

Ordering stringISO7731DWR
PackageSOIC, 16 pins, DW body
CarrierTape and reel, 330 mm reel, 16.4 mm tape, pocket 10.75 by 10.7 by 2.7 mm, Q1
Supplies2.25 V to 5.5 V, each side independent
Temperature rangeminus 55 to plus 125 degrees Celsius
Channel directionTwo forward, one reverse
Default stateOutput high, the F string is the same part with a low default
Alternative packageDBQ 16 body as ISO7731DBQR

Electrical parameters that decide the application

Data rate100 Mbps
Isolation ratingUp to 5000 VRMS per UL 1577
Working voltage1500 VRMS with a projected lifetime above 30 years
Surge isolation capabilityUp to 12.8 kV
Repetitive peak isolation voltage2121 VPK on the DW body
Common-mode transient immunityplus or minus 100 kV per microsecond typical
Propagation delay11 ns typical at 5 V supplies
Supply current1.5 mA per channel typical at 1 Mbps
Level translation2.25 V to 5.5 V on either side
Clearance and creepageAbove 8 mm external, internal gap above 17 micrometres
Default output delaySpecified separately in the switching tables for the default-high and default-low members
System-level ESDPlus or minus 8 kV IEC 61000-4-2 contact across the barrier

Family variants and how they differ

ISO7730Three forward channels, default high
ISO7731Two forward and one reverse, default high, the part on this page
ISO7730FThree forward channels, default low
ISO7731FTwo forward and one reverse, default low
Same die, different maskThe two strings share the rate, the barrier, the supplies and the temperature range, and differ only in the state the output takes when the input disappears
Qualified versionsISO7730-Q1 and ISO7731-Q1 carry the automotive qualifier

Points to check before this part goes on a BOM

Default high is the right choice when a high level means healthy.If the isolated signal feeds an enable that is active high, or a line that the far side reads as a run command, then a high default during a power dip keeps the machine in its working state. That is desirable for a data path and dangerous for a power path, so the direction of the safety argument decides the string.

The default delay is not the same as the propagation delay.The document gives a separate default output delay time for the case where the input side has no supply at all, which is longer than the 11 ns signal path. A controller that waits for a valid level after its own supply comes up has to allow for that default delay, not for the switching figure.

Two forward channels and one reverse is the standard three-wire bridge.Clock and data one way, data the other. It is also the shape of an isolated UART with flow control. The reverse channel is independent of the pair, so its delay is not matched to theirs and does not need to be.

Minus 55 to 125 degrees covers a cold start.The lower end is the notable one. Boards in outdoor cabinets are at ambient until the heater runs, and the difference between minus 40 and minus 55 decides whether the specification covers the site or describes it as out of range.

The DW body carries the higher isolation of the two packages.2121 VPK repetitive peak and above 8 mm clearance against 566 VPK and 3.7 mm on the DBQ body. Both are 5000 VRMS type tested, so a purchasing decision made on the headline figure alone can land on the smaller body and lose the working voltage.

Quantity is printed on the DW rows, not on every row.The addendum prints 2000 against the 330 mm reel on the DW strings and leaves other rows blank or shifted. Confirm the count on the reel label when the order is for a production line rather than a bench.

Choosing between ISO7731DWR and ISO7731FDWR on a real board

The only difference is the state the outputs take when the input side is unpowered or silent. On a data link that feeds a receiver, the high default holds the line idle and prevents a start bit from being generated by a power dip. On a link that feeds a driver enable, the high default would energise the far end, and the F string is the correct order.

Because the two strings are the same die and the same footprint, the decision is reversible at any point before the purchase order, which is why the two are often alternated during a prototype build.

What 100 Mbps costs in power

The 1.5 mA per channel figure is quoted at 1 Mbps, and the dynamic current rises roughly with the toggle rate, so a 100 Mbps stream draws a multiple of that per channel. The isolated supply and the bypass capacitors on both sides have to be sized for the switching case, and the quiescent number is the wrong input to that calculation.

Default high and the first frame after a power dip

With the plain string, the outputs sit high while the input side is unpowered, which reads as an idle line to a UART receiver. The first frame after the input side comes back is therefore generated from a defined state rather than from whatever charge was left on the line, and that is the reason a plain string is often used on a receive-only link.

The same property is a hazard on a transmit enable. A high default would drive the far end for the whole of the power-up interval, so a link that controls a driver has to use the F string and let the far end hold off until the controller asserts the line deliberately.

Both strings are the same die and the same footprint, so the choice is one character on the purchase order. The cost of getting it wrong appears only at the first power dip, which is why the default state belongs in the review notes next to the connector pinout rather than in a comment in the source file.

Where this order code fits

Isolated serial links in cold-climate outdoor equipment and multi-axis drive interfaces use this part when a power dip should leave the far side seeing an idle-high line rather than a low. Teams comparing it with a neighbouring part start from our Pin to Pin Cross Reference page, and teams replacing a part that has gone end of life start from the Date Code Management page.

Questions buyers ask

Is ISO7731DWR the same part as ISO7731FDWR? Same die, same footprint, same ratings. The DWR string defaults high and the FDWR string defaults low when the input side loses power or signal.

Which one is safer? Whichever failure state matches the safe state of the load. A high default is safe for a line that must read idle, a low default is safe for anything that must be de-energised.

Does 100 Mbps apply at every supply voltage? The rate is a family figure at the recommended supplies from 2.25 V to 5.5 V. The delay rises at the lower end of the range, so the timing budget at 2.5 V should be taken from the corresponding switching table.

Can the two sides be at different voltages? Yes. Each side runs from 2.25 V to 5.5 V independently, and the part translates between them.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the How to Verify a Drop in Replacement page sets out the checks that keep a substitute from failing on the bench.