ISO6741FDWR
Product Specifications
ISO6741FDWR
Texas Instruments — Power Management & Signal Chain
Product Overview
The ISO6741FDWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ISO6741FDWR: Three Forward, One Reverse, Default Low, 50 Mbps
ISO6741FDWR is a quad-channel reinforced digital isolator in a SOIC body of 16 pins. It is the three-and-one member of the ISO674x family with the low default, so the reverse channel comes back toward the controller while the three forward channels hold low if the input side loses power.
Order code and package
| Ordering string | ISO6741FDWR |
| Package | SOIC, 16 pins, DW body |
| Carrier | Tape and reel, 2000 pieces, 330 mm reel, 16.4 mm tape, pocket 10.75 by 10.7 by 2.7 mm, Q1 |
| Supplies | 1.71 V to 1.89 V and 2.25 V to 5.5 V, each side independent |
| Temperature range | minus 40 to plus 125 degrees Celsius |
| Channel direction | Three forward, one reverse |
| Default state | Output low, the F suffix |
| Enable pins | Per-side enable, outputs to high impedance |
Electrical parameters that decide the application
| Data rate | 50 Mbps |
| Isolation rating | 5000 VRMS per UL 1577 |
| Working voltage | 1500 VRMS |
| Transient isolation voltage | 7071 VPK |
| Surge isolation voltage | 10000 VPK |
| Common-mode transient immunity | plus or minus 150 kV per microsecond typical, 100 kV per microsecond minimum |
| Propagation delay | 11 ns typical, 18 ns maximum at 5 V and at 3.3 V |
| Propagation delay at 2.5 V | 12 ns typical, 20.5 ns maximum |
| Channel-to-channel skew | 0.2 ns typical at 5 V, 7 ns maximum |
| Part-to-part skew | 6 ns at 5 V, 7 ns at 3.3 V |
| Supply current | 1.6 mA per channel typical at 1 Mbps |
| Clearance and creepage | Above 8 mm external, internal gap above 17 micrometres |
| System-level ESD | Plus or minus 8 kV IEC 61000-4-2 contact across the barrier |
Family variants and how they differ
| ISO6741 | Three forward and one reverse, default high |
| ISO6741F | Three forward and one reverse, default low, the part on this page |
| ISO6740 | Four forward, default high |
| ISO6742 | Two forward and two reverse, default high |
| The F variants | Each of the three direction options has a low-default string, the F sits between the direction digits and the package suffix |
| Qualified versions | ISO6741-Q1 is the automotive member, listed as another qualified version in the addendum |
Points to check before this part goes on a BOM
Three forward and one reverse is the shape of an isolated drive interface.Three command lines out, one fault or status line back. That is the channel count of a gate driver interface, a solid-state relay block or a three-phase sensor front end, and it is the most common quad arrangement in industrial equipment.
The reverse channel is the one that carries the fault.Because the fault path is the reverse channel, its delay and its default state are the two numbers that matter. With the F string a lost forward supply reads as a low fault line, which a controller has to interpret correctly rather than treating a low as healthy.
18 ns maximum against 11 ns typical is the number for a timing budget.The difference between the typical and the maximum is 64 per cent, and at 50 Mbps the unit interval is 20 ns. A budget built on the typical figure has no room for temperature or for part-to-part skew of a further 6 ns.
1500 VRMS working voltage is the number the insulation argument rests on.The 5000 VRMS UL rating is a one-minute type test and the 7071 VPK is a transient. A 690 V AC bus with switching ringing sits near 1000 V peak, which is inside 1500 VPK but only by a factor of 1.5, so the lifetime curves are worth reading before committing. The curves are printed against working voltage and ambient temperature, and a 125 degree ambient shortens the projected life at 1000 V by more than a cooler cabinet does at the same voltage, which is the trade a densely packed drive makes without noticing.
1.6 mA per channel is a 1 Mbps figure.At 50 Mbps the switching current dominates. The isolated supply has to be sized from the switching rows in the supply current tables, and the enable pins let an unused group be shut down to recover the static current.
2000 pieces is the reel quantity.The addendum prints 2000 against the 330 mm reel for ISO6741FDWR, which is the standard DW-16 quantity and matches the sibling ISO6740DWR row.
Fault handling through an isolated reverse channel
The reverse channel carries the fault line back across the barrier, and the isolation means the controller sees it without sharing a ground with the power stage. The delay of 11 ns typical is small against a fault blanking time measured in microseconds, so the isolator is not the item that sets the response.
What does set the response is the default state. A low default means the fault line reads low when the forward side is unpowered, and a controller that treats low as no fault will miss exactly the event it was built to catch. The firmware has to treat a low fault line during a supply ramp as an alarm.
When four channels are better than three plus a discrete
A fourth isolated channel costs less than an optocoupler plus its resistors and its board area, and it removes a part that ages. Where the fourth signal is a status line at a few kilohertz, the 50 Mbps capability is not being used, and what is being bought is the matched timing and the single barrier.
What part-to-part skew costs in a parallel word
Two parts of the same string can differ by 6 ns at 5 V and 7 ns at 3.3 V, and each part can put 0.2 ns of skew between its own channels. A four-bit word split across two packages therefore arrives with up to 7 ns of relative displacement between the halves, which at 50 Mbps is more than a third of a bit.
The cure is to keep a parallel word inside one package, where the 7 ns maximum skew applies to same-direction channels and the 0.2 ns typical is what the eye sees at room temperature. That is one of the reasons the quad parts are bought as quads rather than as pairs.
A second option is to re-time the word after the barrier, sampling it with a clock that is at least 10 ns behind the slowest channel. That costs a register and a clock domain, and it only works if the receiving side has a clock of its own, which a purely combinational interface does not.
Where this order code fits
Isolated drive interfaces, solid-state relay blocks and three-phase sensor front ends use this part where three commands go out and one status line comes back across a 1000 V class barrier. Teams comparing it with a neighbouring part start from our Pin to Pin Cross Reference page, and teams replacing a part that has gone end of life start from the Vendor Consolidation page.
Questions buyers ask
What is the difference between ISO6741DWR and ISO6741FDWR? The default state. The plain string holds the outputs high when the input side loses power or signal, the F string holds them low. Everything else is identical.
Which channel is the reverse one? One channel runs from side 2 back to side 1 and the other three run from side 1 to side 2. The pin functions in the document list the direction of each channel.
Can it be used at 690 V working voltage? The repetitive peak working voltage is 1500 VRMS, which covers a 690 V AC bus. The insulation lifetime curves should still be checked for the expected service life and the pollution degree of the enclosure.
Does the enable pin isolate? The enable pins are per side and put the outputs on that side into high impedance. They do not cross the barrier and they are not a substitute for removing the supply.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the How to Verify a Drop in Replacement page sets out the checks that keep a substitute from failing on the bench.