Contact Us

ISO1450BDWR

Brand: Texas Instruments
Texas Instruments ISO1450BDWR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

ISO1450BDWR — Power Management & Signal Chain | Superb Automation

ISO1450BDWR

Texas Instruments — Power Management & Signal Chain

Product Overview

The ISO1450BDWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

ISO1450BDWR: isolated 50 Mbps RS-485 transceiver with the basic barrier

ISO1450BDWR is a galvanically isolated half duplex RS-485 driver and receiver in a wide body 16 pin SOIC, with the logic side and the bus side on separate supplies and a silicon dioxide barrier between them in a SOIC body of 16 pins. It carries 50 Mbps, loads the bus at one eighth of a unit load so 256 nodes fit, and protects the bus pins to plus or minus 30 kV human body model, plus or minus 16 kV IEC 61000-4-2 contact discharge and plus or minus 4 kV IEC 61000-4-4 fast transient burst. Common mode transient immunity is 100 kV per microsecond typical, the logic side runs from 1.71 V to 5.5 V and the bus side from 3 V to 5.5 V, the receiver is fail safe on an open, shorted or idle bus, and the part is characterised from minus 40 to plus 125 degrees. Driver propagation is 19 ns typical and 41 ns maximum with a pulse width distortion of 1 ns typical and 6 ns maximum.

Order code and package

ISO1450BDWRwide body DW package, 16 pins, 10.30 mm by 10.30 mm, basic isolation, 50 Mbps half duplex. The addendum prints the DW body in a 40 piece tube and the R string on a 2000 piece large reel, but the quantity column drifts by one row in this print, so the reel count is confirmed on the label
ISO1450BDWthe tube row of the same body, which is the form a sample order arrives in
ISO1450DWRthe reinforced member of the same rate and duplex, 10000 VPK of surge against 6000 VPK here
ISO1430BDWR and ISO1410BDWRthe 12 Mbps and the 500 kbps members in the same body and the same basic barrier, so a slower port is a device number change on one line of the bill of materials
ISO1452BDWRthe full duplex member at 50 Mbps, four bus pins instead of two and the same package

Electrical parameters that decide the application

Logic side supply1.71 V to 1.89 V for a 1.8 V rail, or 2.25 V to 5.5 V for the higher rails, which means the part can sit directly on an FPGA bank without a shifter
Bus side supply3 V to 5.5 V, and 5 V is the PROFIBUS condition. The two sides are independent, so the barrier also separates the rails
Signalling rate50 Mbps on this member, against 12 Mbps on the 1430 and 500 kbps on the 1410. All three use the same barrier and the same package
Node countone eighth of a unit load, up to 256 nodes, which is the isolated equivalent of the non isolated 256 node parts and removes the repeater from a long trunk
Bus protectionplus or minus 30 kV human body model, plus or minus 16 kV IEC 61000-4-2 contact discharge and plus or minus 4 kV IEC 61000-4-4 burst on the bus pins, printed as device ratings so no external clamp is needed for those events
Common mode transient immunity100 kV per microsecond typical, which is the figure that decides whether a fast switching node in the same cabinet corrupts a frame across the barrier
Isolation, repetitive peak1500 VPK of maximum repetitive peak isolation voltage, and 1060 VRMS or 2121 VDC of working voltage from the time dependent breakdown test
Isolation, transient7071 VPK of maximum transient isolation voltage, tested at 1.2 times that value for one second on every unit
Isolation, surge6000 VPK on the B version against 10000 VPK on the reinforced version, which is the single electrical difference between the two strings
Spacingmore than 8 mm of clearance and more than 8 mm of creepage, more than 17 um of distance through the insulation and a tracking index above 600, which is what a mains referenced barrier needs on a board
Certifications5000 VRMS for one minute per UL 1577, DIN EN IEC 60747-17 for the VDE file, and the IEC 62368-1, 60601-1 and 61010-1 standards, with CQC, TUV and CSA approvals listed
Switchingdriver propagation 19 ns typical and 41 ns maximum, pulse width distortion 1 ns typical and 6 ns maximum, rise and fall 4.7 ns typical at a 5 V bus and 7.8 ns at 3.6 V
Fail safethe receiver holds a defined output with the bus open, shorted or idle, so a connector pulled on the field side does not put noise into the controller

Family variants and how they differ

B against reinforcedthe same die with a different barrier rating. The B version carries 6000 VPK of surge and the routine test uses 1.2 times the working voltage instead of 1.6 times. Everything else, including the data rate and the package, is identical
1450 against 143050 Mbps against 12 Mbps. The 12 Mbps member covers PROFIBUS and most fieldbus rates, and the 50 Mbps member exists for a short isolated link with a faster protocol
1450 against 1452half duplex against full duplex. The 1452 needs four bus pins and a four wire field cable, which most installations do not have
Against a non isolated transceivera non isolated part costs a fraction of this one and needs no bus side supply, but it cannot bridge a ground difference. The barrier is the product here, not the transceiver
Against a digital isolator plus a transceivertwo parts take more board area and more engineering work, but they let the port use whichever transceiver the customer already qualified. The single package wins on area and on the number of joints

Points to check before this part goes on a BOM

The B suffix is a commercial and certification decision before it is an engineering one. The basic barrier carries 6000 VPK of surge against 10000 VPK on the reinforced version, and the routine test applies a lower multiple of the working voltage. A product that has to claim reinforced isolation under 61010-1 or 60601-1 cannot use this string, even though the data rate, the package and the pinout are the same. The safety file decides, and it should be read before the part number is frozen.

The surge rating on this string is lower than its transient rating, 6000 VPK against 7071 VPK. That is not a printing error: the two tests are different waveforms and different durations, and the surge test is the one that models a lightning or a switching event on a long cable. A customer who reads the transient number as a surge number will overestimate the port, and a surge arrester in front of the bus is still the right answer for an outdoor run.

The part does not generate the bus side supply. An isolated RS-485 port needs a small isolated converter, usually a transformer driver and a centre tapped transformer, and that is a second decision with its own cost and board area. Quoting this part as a complete isolated port leaves that block out, and the customer discovers it at the circuit review rather than at the quotation.

The addendum print for this family is not aligned row by row: the tube and reel quantities appear one line away from the part numbers they belong to, and some rows carry a quantity with no part number at all. The DW body is a 40 piece tube and the DWR string a 2000 piece reel, and that is consistent across the family, but any single row should be confirmed against the label rather than trusted from the text extract.

The fail safe receiver covers an open bus, a shorted bus and an idle bus, which are the three conditions a field cable produces when a connector is pulled, a wire is crushed or a driver releases the pair. It does not cover a wrong termination, a missing termination or a ground difference beyond the common mode window, and those three account for most real field faults.

The logic side accepts 1.71 V, so the part can hang directly on a 1.8 V FPGA bank, and the bus side can run at 5 V for a PROFIBUS segment. That combination, a 1.8 V controller and a 5 V field bus, is the reason this family exists in one package rather than as an isolator plus a level shifter plus a transceiver.

Where an isolated 485 port is needed

Grid equipment, solar inverters, motor drives, HVAC controllers and building automation all put a controller on one earth and a field bus on another, and the difference between the two is what the barrier is for. PROFIBUS at a 5 V bus side supply is named in the feature list, which is why the bus side accepts 5 V as well as 3 V.

In those systems the isolation is usually a safety requirement rather than a noise measure, so the certification list matters as much as the data rate: UL 1577, the VDE standard and the medical and laboratory equipment standards all appear in the same table.

What the order code decides

The string reads ISO1450 for the 50 Mbps half duplex member, B for the basic barrier, DW for the wide body package and R for the reel. The B is the only character that changes the isolation rating, and it does not change anything about the transceiver.

The family number decides the rate and the duplex, so a change from 1450 to 1430 is a slower bus and a change from 1450 to 1452 is a four wire bus. Neither is a substitution a purchaser can make without the engineering file being rechecked.

Where this order code fits

Isolated field bus ports on grid equipment, solar inverters, motor drives, HVAC controllers and building automation, and any port that has to hold 5000 VRMS for a minute per UL 1577 with a 5 V bus side supply. Teams comparing it with a neighbouring part start from our Pin to Pin Cross Reference page, and teams replacing a part that has gone end of life start from the BOM Shortage Recovery page.

Questions buyers ask

What does the B suffix change? Only the barrier. The B version carries 6000 VPK of surge against 10000 VPK on the reinforced string, and its routine test applies 1.2 times the working voltage instead of 1.6 times. Rate, duplex and package are identical.

Does it need a supply on both sides? Yes. The logic side runs from 1.71 V to 5.5 V and the bus side from 3 V to 5.5 V, and the bus side supply has to come from an isolated converter.

Can it sit on a 1.8 V controller? Yes, the logic side accepts 1.71 V to 1.89 V, and the bus side can still run at 5 V for a PROFIBUS segment.

What is the node count? 256 nodes at one eighth of a unit load, on the isolated side as on the non isolated parts of the same rate.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the How to Verify a Drop in Replacement page sets out the checks that keep a substitute from failing on the bench.