ISO1430DWR
Product Specifications
ISO1430DWR
Texas Instruments — Power Management & Signal Chain
Product Overview
The ISO1430DWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ISO1430DWR: isolated 12 Mbps RS-485 transceiver with the reinforced barrier
ISO1430DWR is the 12 Mbps member of the isolated RS-485 line, half duplex in a wide body 16 pin SOIC, with the logic side and the bus side on separate supplies and a reinforced silicon dioxide barrier in a SOIC body of 16 pins. It carries 12 Mbps, loads the bus at one eighth of a unit load so 256 nodes fit, and protects the bus pins to plus or minus 30 kV human body model, plus or minus 16 kV IEC 61000-4-2 contact discharge and plus or minus 4 kV IEC 61000-4-4 fast transient burst. Driver propagation is 68 ns typical and 125 ns maximum with a pulse width distortion of 2 ns typical and 10 ns maximum, and the rise and fall are 10 ns typical at a 5 V bus and 27.8 ns at 3.6 V. The barrier is reinforced: 10000 VPK of surge against 6000 VPK on the basic version, with 1500 VPK of repetitive peak voltage.
Order code and package
| ISO1430DWR | wide body DW package, 16 pins, 10.30 mm by 10.30 mm, reinforced barrier, 12 Mbps half duplex. The addendum prints the tube at 40 pieces and the R string on a 2000 piece large reel, but the quantity column drifts by one row in this print, so the reel count is confirmed on the label |
| ISO1430DW | the tube row of the same body, the form a sample order arrives in |
| ISO1430BDWR | the basic barrier version of the same 12 Mbps member, 6000 VPK of surge instead of 10000 |
| ISO1450DWR | the 50 Mbps member in the same body and the same reinforced barrier, for a port that needs a faster protocol |
| ISO1410DWR | the 500 kbps member, the slow end of the same family, for a long meter trunk where the cable sets the rate |
Electrical parameters that decide the application
| Logic side supply | 1.71 V to 1.89 V for a 1.8 V rail, or 2.25 V to 5.5 V for the higher rails, so the part can sit on an FPGA bank directly |
| Bus side supply | 3 V to 5.5 V, with 5 V for the PROFIBUS condition. The two sides are independent supplies across the barrier |
| Signalling rate | 12 Mbps, which covers PROFIBUS and the faster fieldbus profiles. The family also offers 500 kbps and 50 Mbps in the same package |
| Node count | one eighth of a unit load, up to 256 nodes, which removes a repeater from a long trunk |
| Bus protection | plus or minus 30 kV human body model, plus or minus 16 kV IEC 61000-4-2 contact discharge and plus or minus 4 kV IEC 61000-4-4 burst, printed on the bus pins so no external clamp is needed for those events |
| Driver switching | 68 ns typical and 125 ns maximum of propagation, pulse width distortion 2 ns typical and 10 ns maximum, rise and fall 10 ns typical at a 5 V bus against 27.8 ns at 3.6 V, so a 3.3 V bus is noticeably slower |
| Common mode transient immunity | 100 kV per microsecond typical, the figure that decides whether a switching node in the same cabinet corrupts a frame |
| Isolation, repetitive peak | 1500 VPK, with 1060 VRMS or 2121 VDC of working voltage from the time dependent breakdown test |
| Isolation, transient | 7071 VPK of maximum transient isolation voltage, tested at 1.2 times that value for one second on every unit |
| Isolation, surge | 10000 VPK on this reinforced string against 6000 VPK on the B version, the one electrical difference between the two |
| Spacing | more than 8 mm of clearance and creepage, more than 17 um of insulation thickness and a tracking index above 600 |
| Certifications | 5000 VRMS for one minute per UL 1577, DIN EN IEC 60747-17 for the VDE file and the IEC 62368-1, 60601-1 and 61010-1 standards, with CQC, TUV and CSA listed |
| Fail safe | the receiver holds a defined output with the bus open, shorted or idle, so a pulled connector does not put noise on the controller input |
Family variants and how they differ
| 1430 against 1450 | 12 Mbps against 50 Mbps in the same package and the same barrier. The 12 Mbps part covers PROFIBUS, the 50 Mbps part exists for a faster isolated link, and the two have identical pinouts |
| 1430 against 1410 | 500 kbps against 12 Mbps. A long trunk with heavy termination does not support 12 Mbps, and the slower member is cheaper and has wider timing margin |
| Against the B version | the same die with 6000 VPK of surge instead of 10000 and a lower routine test multiple. A product that claims reinforced isolation cannot use the B string |
| Against a non isolated transceiver plus a digital isolator | two parts take more board area but let the port keep a transceiver the customer already qualified. The single package wins on area and on the number of joints |
| Against the full duplex member | the 1432 carries four bus pins and the same rate. Most fieldbus installations are two wire and use the 1430 |
Points to check before this part goes on a BOM
12 Mbps is the rate that matches PROFIBUS, and that is why this member exists. The 50 Mbps member in the same package is not a drop in upgrade for a PROFIBUS segment, because the cable, the termination and the stub lengths were chosen for 12 Mbps. A customer who wants more headroom should confirm that the physical layer, not just the transceiver, supports the faster rate.
The driver is noticeably slower at a 3.6 V bus side supply than at 5 V, 27.8 ns of rise and fall against 10 ns. A board that runs the bus side at 3.3 V to save a rail still meets 12 Mbps, but the eye at the far end is smaller, and a long cable that worked at 5 V may not work at 3.3 V with the same termination.
The reinforced barrier here gives 10000 VPK of surge, and the basic version of the same part gives 6000 VPK. The difference is not visible in the pinout, the package or the price band alone, and it is the first thing a safety reviewer will ask about. A bill of materials that names the wrong string passes every electrical test and fails the certification.
The addendum print for this family is offset: tube and reel quantities appear one line away from the part numbers they belong to, and some rows carry a quantity with no part number. The 40 piece tube and the 2000 piece reel are consistent across the family, but a single row should be confirmed against the label before it goes on a purchase order.
The isolated side needs its own supply, which usually means a small transformer driver and a transformer. That block is not in this package, and a customer who expects the transceiver to generate the bus side rail will find the port does not work when only one rail is present.
The fail safe receiver covers the open, shorted and idle bus conditions. It does not cover a missing terminator or a ground difference beyond the common mode window, and those are the two faults that show up most often on a site visit. A port that fails intermittently in wet weather is usually a termination or a shield problem and not this part.
Where 12 Mbps isolated ports are used
PROFIBUS segments, grid equipment, solar inverters, motor drives and HVAC controllers are the applications the vendor prints. In each case the controller sits on one earth and the field cable on another, and the barrier is a safety requirement as much as a noise measure.
The 12 Mbps member is the workhorse of that list because the installed cable and the installed termination were sized for it, and swapping in a faster transceiver does not change the cable.
What the order code decides
The string reads ISO1430 for the 12 Mbps half duplex member, no B for the reinforced barrier, DW for the wide body package and R for the reel of 2000.
Adding a B after the family number changes the surge rating and the routine test multiple and nothing else. Changing 1430 to 1450 changes the rate. Both are engineering decisions, and neither is a substitution a purchaser can make alone.
Where this order code fits
PROFIBUS segments, isolated field bus ports on grid equipment, solar inverters, motor drives and HVAC controllers, wherever a 12 Mbps two wire segment has to cross a barrier with a reinforced rating. Teams comparing it with a neighbouring part start from our Pin to Pin Cross Reference page, and teams replacing a part that has gone end of life start from the BOM Shortage Recovery page.
Questions buyers ask
What is the difference to the B version? The B version carries 6000 VPK of surge against 10000 VPK here, and its routine test applies a lower multiple of the working voltage. Rate, duplex and package are identical.
Why not use the 50 Mbps member? The cable and the termination on a PROFIBUS segment were sized for 12 Mbps. The faster part is not an upgrade unless the physical layer is also changed.
How fast is the driver at a 3.3 V bus side? Rise and fall of 27.8 ns against 10 ns at 5 V, so the eye is smaller. The rate is still met, the margin is not the same.
How many nodes fit? 256 at one eighth of a unit load, on the isolated side as on the non isolated parts of the same rate.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the How to Verify a Drop in Replacement page sets out the checks that keep a substitute from failing on the bench.