Contact Us

INA290A1IDCKR

Brand: Texas Instruments
Texas Instruments INA290A1IDCKR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

INA290A1IDCKR — Power Management & Signal Chain | Superb Automation

INA290A1IDCKR

Texas Instruments — Power Management & Signal Chain

Product Overview

The INA290A1IDCKR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

INA290A1IDCKR: 120 V current sense amplifier at 20 V per V in a six pin SC70

INA290A1IDCKR is a high side current sense amplifier in the six pin DCK body that measures across a shunt sitting anywhere between minus 20 V and 122 V, amplifies by 20 and delivers a 1.1 MHz signal from a 2.7 V supply in a SC70-6 body of 6 pins. The INA290 is a single channel current sense amplifier with a 2.7 V to 120 V common mode range and a survival rating of minus 20 V to 122 V on the inputs. The A1 grade has a fixed gain of 20, an offset of 12 uV maximum and an offset drift of 0.2 uV per degree, and the amplifier holds 160 dB of rejection at DC and 85 dB at 50 kHz. Gain error is 0.1 percent maximum with 5 ppm per degree of drift, which is what allows the part to be used for a measurement rather than only for a fault trip.

Order code and package

Order codeINA290A1IDCKR
Common mode range, operating2.7 V to 120 V
Common mode range, survivalminus 20 V to 122 V
Gain20 V per V
Supply voltage2.7 V to 20 V
Bandwidth1.1 MHz
Packagesix pin SC70, DCK body
DocumentSBOS961C, revised June 2021

Electrical parameters that decide the application

Common mode rejection at DC160 dB
Common mode rejection at 50 kHz85 dB
Gain errorplus or minus 0.1 percent maximum
Gain driftplus or minus 5 ppm per degree maximum
Offset voltageplus or minus 12 uV maximum
Offset driftplus or minus 0.2 uV per degree maximum
Supply range in the electrical table2.7 V to 20 V
Quiescent current at 120 V common modea few hundred microamps, rising with common mode voltage
Reference inputsets the zero current output level
Outputrail to rail, driving a capacitive load up to the specified limit

Points to check before this part goes on a BOM

Twelve microvolts of offset is the number that decides the smallest shunt this part can work with. Across a 1 milliohm shunt that offset is 12 uA of current error, and across a 0.1 milliohm shunt it is 120 uA. On a 20 A rail the first case is 0.06 percent of full scale and the second is 0.6 percent, so the shunt value and the offset have to be chosen together. The 0.2 uV per degree drift adds 8 uV over a 40 degree rise, which is another 8 uA on the same 1 milliohm shunt, and that term is what a calibration at room temperature does not remove.

The rejection figures are quoted at two frequencies and the second one is the honest number for a switching rail. At DC the 160 dB is a factor of a hundred million, so a 48 V common mode step produces 0.48 uV at the input, invisible against the offset. At 50 kHz the 85 dB is a factor of 17783, so the same 48 V step produces 2.7 mV at the output, which divided by the gain of 20 is 135 uV at the input and 135 mA of apparent current on a 1 milliohm shunt. A converter switching at 50 kHz with 48 V of swing on the shunt therefore puts more error into the reading than the offset does.

The common mode range reaches 120 V and the survival rating reaches 122 V, a margin of 2 V. That is a small margin on a rail that can ring, and the datasheet deals with it by defining the survival condition as a limit rather than as a continuous operating point. A 96 V battery stack that is charged to 110 V is inside the operating range with 10 V to spare. A 110 V stack with a 15 V transient is not, and the part is not the component that should absorb that transient, so a rail with inductive transients belongs behind a clamp.

A gain of 20 with a 1.1 MHz bandwidth means the amplifier is doing the work with a closed loop that is wide enough to see switching edges on the shunt. That is useful for a peak current loop and awkward for an average current measurement, because the output carries the switching ripple as well as the average. An RC filter on the output is the usual answer, and the corner it needs depends on the switching frequency: at 100 kHz a 10 us time constant removes the ripple and adds a delay that a current mode loop may not tolerate.

The six pin SC70 body has no room for a separate reference pin on the analog side, so the zero current level is set by a voltage on the reference input, which is also the point where a ratiometric measurement is created. If the reference is the same supply that feeds the analog to digital converter, the measurement is ratiometric and the supply tolerance cancels. If the reference is a separate precision source, the supply tolerance stops mattering but the reference tolerance enters directly, and the two errors are not the same size.

Bidirectional current needs the reference at half the converter range, and that halves the usable span. With a 3.3 V converter and a 1.65 V reference, the output swings 1.65 V in each direction, which at a gain of 20 is 82 mV of shunt signal, or 82 A on a 1 milliohm shunt. The same measurement unidirectional uses the whole 3.3 V and reaches 165 A. A board that starts bidirectional because the load can regenerate gives up half its resolution, which is worth knowing before the shunt is chosen.

The 20 V supply maximum is above every logic rail in a 48 V system and well below the 120 V common mode, which is the whole point of a current sense amplifier with a high voltage front end. The supply pin therefore comes from the low voltage side, and the input stage floats. That separation is what makes the part easy to use and what makes its ground reference important: the output is referenced to the low side ground, so the return of the shunt and the return of the amplifier meet at one point, and a difference between them appears as an offset in the reading.

Where this order code fits

This order code belongs on 48 V telecom rails, 60 V battery stacks, motor phase current sensing and 400 V class systems where the shunt sits on the high side and the measurement has to survive a short circuit on the load. It is also the part chosen when a controller needs to read current on a rail that swings, because the common mode range reaches the full 120 V and the inputs survive 20 V below ground, which is what an inductive load produces at turn off. Teams comparing it with a neighbouring part start from our Amplifier Cross Reference page, and teams replacing a part that has gone end of life start from the Power Management Cross Reference page.

Questions buyers ask

What is the smallest shunt this part can resolve? With a 12 uV offset and a 20 V per V gain, the input referred resolution floor is the offset itself, so a 1 milliohm shunt gives 12 uA and a 0.1 milliohm shunt gives 120 uA. The choice is a trade between the loss in the shunt and the resolution of the measurement, and the offset drift of 0.2 uV per degree is the term that decides whether a room temperature calibration holds over the operating range.

Does it work on a 48 V rail with a 60 V transient? The operating range reaches 120 V, so a 60 V transient is inside it with a factor of two of margin. The survival rating of 122 V is for the conditions the document defines, and a rail with repetitive ringing above that needs a clamp rather than a part with a higher rating, because no current sense amplifier is intended to absorb inductive energy.

Can it measure current in both directions? Yes, with the reference set to half the converter range. That halves the output swing in each direction, so the usable shunt signal at a 3.3 V converter is 82 mV with a gain of 20. Bidirectional sensing is the right choice for a load that regenerates and a poor choice for one that does not, because it halves the resolution for no benefit.

How much error does switching noise add? At 50 kHz the rejection is 85 dB, so a 48 V common mode step becomes 2.7 mV at the output, which is 135 mA of apparent current on a 1 milliohm shunt. At DC the same step is 0.48 uV and irrelevant. The frequency of the switching on the rail, not the DC accuracy, decides whether an output filter is needed.

SUPERB holds and sources this amplifier line against the exact order code, with the reel, date code and country of origin stated on the offer. When a measurement channel has to move to a second part, the BOM Shortage Recovery page sets out the checks that separate a working substitute from one that fails on the bench.