INA125UA
Product Specifications
INA125UA
Texas Instruments — Power Management & Signal Chain
Product Overview
The INA125UA from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
INA125UA: the A grade bridge amplifier with an integrated reference, SO-16 tube
The INA125UA is the tighter offset bin of the surface mount bridge amplifier, in the SO-16 body supplied 40 pieces to a tube. It combines the two features that make this family useful, a pin selectable reference and a gain from 4 to 10,000, with the better of the two laser trimmed offset bins. On a bridge channel that has no electronic trim the bin is the zero error of the channel.
The reference and the amplifier drift together because they share a die, and the residual drift of the two is what the 2 µV per degree amplifier row and the reference specification together produce. That is the argument for an integrated front end, and it holds whether the grade is the plain bin or the A bin.
The INA125UA rows as the addendum publishes them
| Part class | Instrumentation amplifier with precision voltage reference |
| Vendor status | ACTIVE, production data |
| Data sheet | SBOS060 |
| Grade | A suffix, tighter trimmed offset bin |
| Reference voltages | 1.24 V, 2.5 V, 5 V, 10 V by pin strap |
| Gain equation | G = 4 + 60 kΩ divided by RG |
| Input offset voltage | 250 µV maximum, family row |
| Offset drift | 2 µV per degree maximum |
| Input bias current | 20 nA maximum |
| Common mode rejection | 100 dB minimum |
| Quiescent current | 460 µA |
| Sleep pin | Shuts the amplifier and the reference |
| Body | SOIC, D outline, 16 pins |
| Carrier | 40 pieces per tube |
| Reel sibling | INA125UA/2K5, 2500 pieces |
| Plain bin sibling | INA125U, same body and tube |
| Moisture level | Level 3, 260 degrees, 168 hour floor life |
| Temperature range | Minus 40 to plus 85 degrees |
The three rows that matter for a purchase are the grade, the carrier and the moisture level. The grade is invisible on the body unless the marking is read, the carrier determines how many times the parts are exposed, and the moisture level determines whether exposure matters at all. A build that reads those three off the addendum and puts them on the purchase order will not have a receiving surprise.
A bridge channel without a trim network
The usual reason to specify an integrated bridge amplifier is that the channel has no room for a trim, either physically or in the test time. A pot, a resistor and a test step cost more than the grade difference on any volume, and a sealed transmitter cannot be trimmed after potting at all. The A bin reduces the zero error from the amplifier, and the bridge's own offset is trimmed at the sensor or accepted.
The combination means the residual zero error is the sum of the bridge offset and the amplifier offset, and neither can be removed. A channel that needs a 0.1 per cent zero specification on a 10 mV full scale needs 10 µV, which is far below what this part offers at any grade; the honest conclusion is that such a channel needs a chopper stabilised amplifier or a per unit calibration, not a tighter bin.
Reference accuracy and the ratiometric cancellation
The reference tolerance affects the absolute accuracy of a channel that measures against an absolute voltage, and it cancels in a ratiometric channel. That distinction decides whether the grade and the reference tolerance matter to the customer's specification, and it is worth stating in a quotation because a customer often assumes the reference is the dominant error when the wiring makes it irrelevant.
Where the reference does matter is a channel that also measures a supply or a temperature with an absolute reference, which is a common arrangement in a transmitter with two inputs. In that case the reference tolerance and drift are directly in the error budget, and the integrated reference is being used as a system reference rather than as an excitation source.
Sleep and the 460 µA in a transmitter
The sleep pin makes a battery transmitter practical, and the wake up settling of the reference sets the measurement delay. A bandgap with a 1 µF output takes a few milliseconds, which is fast compared with a sensor's thermal time constant and slow compared with a microcontroller's instruction cycle. The control software therefore has to wait a fixed time rather than poll, and the fixed time should be measured rather than guessed.
A mains powered transmitter does not need the sleep pin, and leaving it tied high removes a failure mode. The pin is still a digital input with a threshold, so it must not be left floating, which is the one wiring mistake that produces intermittent behaviour in a cabinet.
Buying INA125UA
The tube is active, the reel sibling is active, and the grade is the A bin. A build of a few hundred boards takes the reel; a prototype takes the tube. The 40 piece tube is small enough that a build of 500 boards needs thirteen tubes, which is thirteen exposure records at level 3.
For a transmitter programme, our PPAP submission checklist page covers the documentation for an automotive sensor, and the supplier quality audit page covers the moisture and handling controls we expect at the assembly house.
Compensating a bridge channel over temperature
A bridge sensor has its own temperature coefficient, and the integrated reference does not remove it: the reference and the amplifier drift together, but the bridge's sensitivity and its offset drift separately. A channel that holds its zero over temperature can still lose span, and the correction is a temperature measurement and a polynomial in the control software rather than a better amplifier.
The practical arrangement is to measure the bridge temperature with a second channel and apply a two coefficient correction: a span term and a zero term. The span term is the bridge's sensitivity coefficient, typically a few hundred parts per million per degree for a silicon strain gauge, and the zero term is the bridge's offset drift, which is larger and less predictable. Both are calibrated per unit at two temperatures, and the calibration is the expensive part of the instrument rather than the electronics.
Where the amplifier matters is the part of the drift it contributes, which on this family is 2 µV per degree. On a 10 mV full scale that is 0.02 per cent per degree, which over 40 degrees is 0.8 per cent, and that is comparable with the bridge's own zero drift. The two cannot be separated after the instrument is built, which is why the amplifier drift figure belongs in the error budget rather than in a footnote.
One further point on the sleep pin: on a board that never sleeps, tie it to the supply through a resistor rather than directly, so that a probing mistake does not short the supply to ground through a digital input. A 10 kΩ resistor costs nothing and removes a failure mode on a bench that is used for rework. The same resistor on a board that does sleep is a small series impedance that the driving output has to charge, and at the frequencies involved it is invisible.
Questions that arrive with this part number
Whether the A bin changes the reference accuracy is the first question, and it does not: the grade applies to the amplifier offset, and the reference is trimmed to its own specification on both rows. Whether the part can be used with a 3.3 V supply and a 2.5 V bridge excitation is the second, and it can, with limited headroom and a bridge current that needs a pass device. The third is the tap strapping, which is fixed in copper.
The fourth is the tube quantity. A customer who expects a reel and receives tubes has a line that needs a feeder change, and the correction is a purchase order amendment rather than a new board revision, provided it happens before the build.