Contact Us

DRV5013ADQDBZRQ1

Brand: Texas Instruments
Texas Instruments DRV5013ADQDBZRQ1 is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

DRV5013ADQDBZRQ1 — Power Management & Signal Chain | Superb Automation

DRV5013ADQDBZRQ1

Texas Instruments — Power Management & Signal Chain

Product Overview

The DRV5013ADQDBZRQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

DRV5013ADQDBZRQ1: A Bipolar Hall Latch at 2.7 mT That Only Changes State When the Field Reverses

DRV5013ADQDBZRQ1 is a chopper stabilised bipolar latch Hall sensor with an open drain output in a SOT-23 (DBZ) body of 3 pins. It runs from 2.5 V to 38 V, sinks 30 mA, and switches state only when the magnetic field crosses zero and builds in the opposite direction. The AD option on this order code uses plus or minus 2.7 mT, which suits a ring magnet on a shaft where the poles pass the sensor one after the other. A latch is not a switch: a unipolar part that sees the same field twice reports the same state twice, while this part reports alternate states, which is why it can count revolutions without a microcontroller edge detector.

Order code and package

Ordering stringDRV5013ADQDBZRQ1, SOT-23, large reel
Family documentDRV5013, SLIS150N, March 2014, revised July 2025
Sensitivity codeAD, plus or minus 2.7 mT, non inverted output
PackageSOT-23 (DBZ), 3 pins, 2.92 mm by 2.37 mm
Ambient range on the Q grademinus 40 to plus 125 degrees
Ambient range on the E grademinus 40 to plus 150 degrees
Junction rangeminus 40 to plus 150 degrees on Q, 175 degrees on E
Through hole siblingLPG and LPE, TO-92, 4 mm by 3.15 mm
Output typeopen drain, 30 mA sink, needs a pull up
Inverted versionsND and FD, output state reversed for the same field

Electrical parameters that decide the application

Supply range2.5 to 38 V, no external regulator required
Absolute maximum supply40 V, reverse to minus 22 V
Output pin voltage0 to 38 V
Output sink30 mA maximum during recommended operation
Power on time35 us to a valid output
Reverse supply protectionminus 22 V, tested to minus 20 V
Load dumpsurvives 40 V
Operate point, AD optionplus or minus 2.7 mT, plus or minus 10 per cent over temperature
Release point, AD optionopposite polarity, plus or minus 2.7 mT
Hysteresisset by the latch action, the output holds its state until the field reverses
Output short circuitinternally limited, no external clamp needed
ESD, human body modelplus or minus 2500 V
ESD, charged device modelplus or minus 500 V

Family variants and how they differ

DRV5013FA and FDplus or minus 1.3 mT, the most sensitive option, small magnets
DRV5013AD and NDplus or minus 2.7 mT, the part on this page
DRV5013AGplus or minus 6 mT, for wide gaps and coarse targets
DRV5013BCplus or minus 12 mT, for a strong field and heavy mechanical tolerance
ND and FDsame magnetic windows with the output state inverted
DRV5023unipolar switch, changes state on one polarity only
DRV5053analogue output, reports field strength instead of a latched state
What the letter changesthe magnetic window and the output polarity, nothing electrical

Points to check before this part goes on a BOM

The latch behaviour is the whole point of the part. A bipolar latch sets its output low when the south pole comes close and keeps it low after the magnet has moved away, then releases it only when a north pole arrives. On a brushless motor with three phases and three sensors, that is exactly the commutation pattern wanted, and it is why these parts are still the standard choice for a sensored drive. A unipolar switch in the same position would need the field to fall below its release point between poles, and on a closely spaced ring magnet the field never does, so the output would sit in one state and the motor would not start.

The 2.7 mT window in the middle of the range is the safe default. The 1.3 mT option gives more output with a weak magnet, but it also responds to stray fields from a nearby solenoid or a brush motor, and the release can be late enough to shift commutation by a few electrical degrees. The 6 mT and 12 mT options are for a target that is far away or a mechanism where the magnet cannot be positioned precisely, and they are less sensitive to stray field in the same proportion. Choosing between them is a matter of measuring the field at the sensor face across the mechanical tolerance stack, then picking the window whose operate point sits at roughly half the minimum field available.

Temperature stability comes from the chopper stage, and the data sheet bounds it at plus or minus 10 per cent of the operate point. For a Neodymium ring magnet the flux falls by about 12 per cent between 20 and 125 degrees, so the field at the sensor moves much more than the threshold does, and the margin between the two is what has to be checked. A motor that commutates correctly on a bench at 25 degrees can lose a sensor at 120 degrees if the magnet was sized to the operate point with no headroom. The usual rule is to keep the minimum field at the sensor at least twice the maximum operate point across the full temperature range.

The three pin footprint keeps the board simple but the pull up still decides the edge rate. With a 10 kOhm resistor to 3.3 V the output rises in a few microseconds into 50 pF, which is fast compared with the mechanical event. For a high speed shaft, a lower resistor gives a sharper edge and reduces the jitter that a comparator sees, at the cost of supply current. The 30 mA sink rating allows 110 Ohm at 3.3 V, and at 24 V the same current limit forces 800 Ohm, so a product that runs the sensor from the 24 V rail should not also expect a 1 kOhm pull up. The output is protected against a short to ground, so a wiring fault at commissioning does not destroy the part, but it does hold the line low until the fault is removed.

What the three pin circuit looks like on a real board

Only three connections are made to the sensor: supply, ground and the open drain output into the controller, plus a pull up resistor from the output to the supply rail. The supply needs a 0.01 uF ceramic capacitor within a few millimetres of the VCC pin, because the chopper stage draws a switching current that a long trace turns into a supply ripple and then into a jittered trip point. An optional 680 pF capacitor from the output to ground slows the edge and filters short spikes from a motor brush, at the cost of a slightly later edge into a fast counter. On a three phase motor the three sensors are usually mounted on a small board around the shaft, and the pull ups are best placed at the controller end so a shorted harness does not burn a resistor on the sensor board.

Where this order code fits

Brushless motor commutation, flow meters, tachometers, valve and solenoid position and power tool triggers are the usual places. A team replacing a mechanical cam and microswitch with a Hall latch usually starts from the 2.7 mT window and adjusts the magnet, not the part. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Pin to Pin Cross Reference page.

Questions buyers ask

Does the output stay low when the magnet is removed? Yes. That is the difference between a latch and a switch. It keeps the last state until a field of the opposite polarity arrives.

Can it be used as a proximity switch? Only if the target alternates polarity. For a plain steel target, a unipolar switch such as the DRV5023 is the right part.

What supply current should a battery product budget? The device itself draws a few milliamps continuously, so a battery product needs a switched supply or the DRV5032 family, which samples instead of running continuously.

Is the E grade available in the same package? Yes, the E grade covers 150 degrees ambient in the same SOT-23 body, and it is ordered by its own string rather than by changing a suffix on this one.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the How to Verify a Drop in Replacement page sets out the checks that keep a substitute from failing on the bench.