DRV2605LYZFR
Product Specifications
DRV2605LYZFR
Texas Instruments — Power Management & Signal Chain
Product Overview
The DRV2605LYZFR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
DRV2605LYZFR: haptic driver with a licensed effect library in a nine bump DSBGA
DRV2605LYZFR is a 2 V to 5.2 V haptic driver that drives both linear resonance actuators and eccentric rotating mass motors from an I2C bus in a DSBGA body of 9 pins. The part carries a licensed TouchSense 2200 effect library from Immersion, so a short command from the host plays a stored waveform instead of a stream of samples. The DSBGA YZF body is the 3000 piece large reel row and the ZFT suffix is the 250 piece small reel row.
Order code and package
| DRV2605LYZFR | DSBGA YZF, 9 bumps, 0.5 mm pitch, 3000 pieces on a large reel, marking 2605L |
| DRV2605LYZFT | same body, 250 pieces on a small reel, marking 2605L |
| DRV2605LDGSR | VSSOP DGS, 10 pins, 2500 pieces on a large reel, marking 05L |
| DRV2605LDGST | VSSOP DGS, 250 pieces on a small reel |
| Moisture level | Level 1, 260 C, unlimited floor life on the YZF body; Level 2, one year, on the DGS body |
| Temperature | minus 40 to plus 85 C operating free air temperature on every row |
| Supply | 2 V to 5.2 V at the VDD pin, with the digital interface tolerant to 1.8 V logic |
Electrical parameters that decide the application
| VDD operating range | 2 V to 5.2 V, the whole span covered by one silicon |
| Quiescent current | 4.1 uA typical and 7 uA maximum, which is the standby figure with the device enabled |
| Shutdown current | 4 uA typical and 7 uA maximum with the EN pin low |
| SCL clock | 400 kHz with no wait states, so a full effect command fits inside one millisecond |
| PWM output frequency | 19.5 kHz to 21.5 kHz, 20.5 kHz nominal, which keeps the drive above the audio band |
| LRA resonant frequency | 125 Hz minimum after revision A, which raised the floor from 50 Hz |
| Over current detection | load impedance threshold of 4 ohm between OUT+ and GND or OUT minus and GND |
| REG pin | 1.83 V internal regulator output, used as the reference for the analogue input path |
Family variants and how they differ
| YZF body | 9 bump DSBGA at 0.5 mm pitch, the smallest of the two bodies, Level 1 moisture |
| DGS body | 10 pin VSSOP, Level 2 moisture with a one year floor life, same silicon and same register map |
| Reel split | R suffix is the large reel, T suffix is the small reel, and the two are the same part electrically |
| Marking | 2605L on the DSBGA, 05L on the VSSOP, which matters when a reel label is missing |
| Effect library | one LRA library and six ERM libraries held inside the device, over one hundred effects in total |
| Playback modes | library playback through the sequencer, real time playback from the host, and audio to vibration |
Points to check before this part goes on a BOM
The effect library lives in the device, not in the host, so the firmware only sends an effect number and a trigger. That is the reason a change of haptic feel in the field can be made with a register write rather than a firmware release, provided the new feel comes from the stored library.
Auto calibration has to run on every actuator at the end of the line. The routine measures back EMF through the drive pins and writes the results into volatile registers, so the values are lost when the rail drops. Either the host reruns calibration on every power up, or it restores the values it saved, and in both cases the actuator has to be the same one that was calibrated.
The resonance tracker needs a clean back EMF window. Long or unbalanced leads to the actuator add series resistance and capacitance that shift the detected resonance, so the tracking locks onto a frequency the actuator does not actually want. Keep the two leads short, equal in length and away from the switching supply that feeds the amplifier.
The 4 ohm over current threshold only protects against a hard short. A coil that has partially shorted turns will read above 4 ohm and the fault will not assert, while the drive current rises and the actuator runs hot. The threshold is a protection aid, not a test of actuator health.
An unused trigger input must be tied to ground. The revision history for the part records this as an added requirement, and a floating IN/TRIG pin on a noisy board produces spurious triggers that look like firmware faults.
The audio to vibration coupling capacitor changed from 0.1 uF to 1 uF. A reference build copied from an older document will have the wrong value and will roll off the low end of the vibration response, which is exactly the band a handheld device uses.
What the bus has to carry
A full effect command is an address byte, a register address and one data byte, so at 400 kHz the transfer is a few tens of microseconds. The bus load is therefore set by how often the product triggers, not by the library size.
The sequencer holds eight slots and each slot can be an effect, a wait or a go to, which is enough for most alert patterns. A pattern that needs more than eight steps has to be built as two sequences and chained by the host.
Where it goes wrong in volume
The common field failure is not the driver but the actuator mounting. A motor that is not held against the mass it is meant to excite draws a different current for the same drive level, and the closed loop compensates by raising the drive, which shortens the life of the motor.
The second is calibration drift after a drop. The stored values are still in the registers, but the actuator is no longer the one that was measured, so the felt strength changes while the register map says everything is nominal.
Where this order code fits
Handheld medical instruments, industrial control panels, telecom test handsets and wearable accessories all use this class of driver, because the actuator is the part the user touches and the feel has to be repeatable from unit to unit. The I2C command set also lets a product change its alerts by market without changing the actuator. Teams comparing it with a neighbouring part start from our Medical Device Components page, and teams replacing a part that has gone end of life start from the Power Management Cross Reference page.
Questions buyers ask
Does the host have to stream a waveform to get a vibration? No. In library mode the host writes an effect number into the sequencer and sets the GO bit, and the device plays the stored waveform. Streaming is only needed in real time playback mode, where the host supplies the samples.
Is the same part usable with both motor types? Yes. The device drives an ERM motor in open or closed loop and an LRA in closed loop with resonance tracking, and the mode is chosen by register. The calibration routine differs between the two, so the production test step has to know which actuator is fitted.
Why does the quiescent current matter here? Because the driver sits on the battery rail of a handheld product that spends most of its life idle. At 4.1 uA typical the driver is not the reason a product fails a shelf life target, but a host that leaves the device enabled and the amplifier biased is.
What does the part do when the actuator is disconnected? The output impedance in shutdown is 15 kohm to ground on each output, so an open actuator produces no drive current and the effect is silent rather than a fault. A production test that only checks for sound will pass a unit with a broken flex.
Can this row be cross shipped with the VSSOP row? Electrically yes, the register map is the same. On the board no, because a 9 bump DSBGA at 0.5 mm pitch and a 10 pin VSSOP do not share a footprint, so the body has to be named on the order.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the How to Verify a Drop in Replacement page sets out the checks that keep a substitute from failing on the bench.