The BQ294522DRVR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
BQ294522DRVR: a 4.45 V second level trip in the same 6 pin body
The BQ294522DRVR is the same secondary overvoltage protector as its 4.4 V sibling, with the trip point moved up by 50 mV to 4.45 V. The delay is 4 seconds, the accuracy is plus or minus 10 mV, the supply current is about 1 microamp and the output is active high. Two or three cells in series, one sense input per cell, and a fixed threshold that cannot be changed in the field.
The 50 mV is the whole reason this code exists. On a cell that charges to 4.2 V, a 4.4 V second level trip leaves 200 mV of headroom and a transient that survives the primary protection has to be large before the fuse goes. On a high voltage cell that charges to 4.35 V, the same 4.4 V trip leaves only 50 mV, which is inside the tolerance of a charge cycle with a little overshoot, and the second level would act during normal operation. The 4.45 V member restores the margin for that chemistry.
Everything else is shared: the 6 pin WSON body, the 4 second delay, the active high output and the 1 microamp supply current that lets the protection stay armed for the shelf life of the pack.
Key data for the BQ294522DRVR
| Function | Secondary overvoltage protection, one input per cell |
| Cell count | 2 series or 3 series |
| Overvoltage threshold | 4.45 V fixed in the silicon |
| Threshold accuracy | Plus or minus 10 mV |
| Delay | 4 seconds fixed |
| Output | Active high after the delay expires |
| Supply current | About 1 microamp |
| Package | WSON, 6 pins, DRV body |
| Temperature | Minus 40 to 85 C |
| Ordering | 3000 pieces on a large tape and reel, 250 on a small reel, marking 4522 |
| Moisture level | Level 2 at 260 C, one year floor life |
Matching the second level to the cell, not to the family
A pack specification usually names the primary protector and leaves the second level to whoever builds the pack. That is how a 4.45 V cell ends up behind a 4.35 V second level trip, which is a pack that blows its fuse on the first full charge at a low temperature. The rule is simple: the second level trip must sit well above the highest voltage the cell can reach in normal charging, including the charger tolerance and the temperature compensation, and well below the point where the cell is being damaged.
On a 4.2 V cell with a charger that holds plus or minus 1 per cent, the cell sees at most 4.242 V, and a 4.4 V trip leaves 158 mV. On a 4.35 V cell with the same charger, the ceiling is 4.394 V, and a 4.4 V trip leaves 6 mV. That is not a margin, and the 50 mV step to 4.45 V is what turns the number back into a margin.
Temperature compensation moves the ceiling further. A charger that compensates for cold cells charges to a higher voltage below 10 C, and the second level has to clear that too. Check the charger curve against the trip point, not against the nominal cell voltage.
What happens after the output goes high
On this family the output stays high as long as the overvoltage condition holds, and it releases when every cell falls below the trip point minus the hysteresis. In a fuse arrangement the fuse is already open by then, so the release does not restore the pack. In a charge FET arrangement the pack can recover, which is the reason some builds use the output to switch a FET rather than to blow a fuse.
The distinction matters at the system level. A blown fuse is a service event: the pack is scrap or it goes back to a service centre. A switched FET is a recovery event, and the product may work again once the fault clears. Neither is better in general, and the choice belongs in the pack specification rather than in the bill of materials.
Where it fits in a build
This is the row for packs built around 4.35 V or 4.4 V cells: high energy density handset packs, thin notebook packs and power tool packs that trade cycle life for capacity. Two and three series only, and the 4 series build needs the 4 series member of the family.
For a board where the protection device sets the substrate class and the coating, the PCBA quote checklist page covers the questions we ask before a quote becomes a build.
The sourcing side of this part is covered on the supplier quality audit. For a protection part that sets the pack safety case, that page covers what we check at the supplier before a reel is accepted.
Questions we get on this code
Is the difference between the 4.4 V and 4.45 V parts only the threshold? Electrically yes, and the marking differs so the two can be told apart on the reel. The delay, the accuracy, the output type and the package are the same, which means a board can carry either one and the difference is the fuse margin.
Does the part need a series resistor on each sense input? The family is specified with a resistor in the sense path, and the document shows the arrangement. Leaving it out exposes the input to the transients that come down a pack harness.
Can it be used on a 3 series pack with one cell bypassed? No. The inputs are differential and each one has to see a real cell. A bypassed position reads as an overvoltage at power up.
What is the shelf life impact of the 1 microamp current? On a 5 Ah pack that is about 8.8 mAh a year, which is well inside the self discharge of the cells. It is not the reason a stored pack loses charge.