Contact Us

AMC1311QDWVRQ1

Brand: Texas Instruments
Texas Instruments AMC1311QDWVRQ1 is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

AMC1311QDWVRQ1 — Power Management & Signal Chain | Superb Automation

AMC1311QDWVRQ1

Texas Instruments — Power Management & Signal Chain

Product Overview

The AMC1311QDWVRQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

AMC1311QDWVRQ1 automotive grade 2 V input isolated amplifier in the eight pin DWV body

The AMC1311QDWVRQ1 is the automotive qualified member of the AMC1311 line, with AEC-Q100 grade 1 qualification over minus 40 to plus 125 C and functional safety documentation available for a system level safety case. Electrically it is the same isolated voltage amplifier as the industrial part: a 2 V high impedance input, a fixed gain of one, a differential output centred at 1.44 V and a reinforced barrier rated at 5000 V RMS and 7000 V peak.

The automotive suffix is not a marketing label. It changes the qualification file, the temperature grade, the documentation package and the traceability a tier one supplier has to keep, and it changes what a customer can claim in a functional safety argument. A part that is functionally identical to an industrial device still cannot be substituted into a safety case without the qualification evidence, and that evidence is the reason this code exists at its own price point.

Key parameters taken from the AMC1311QDWVRQ1 document

QualificationAEC-Q100 grade 1, minus 40 to plus 125 C ambient, with functional safety capability and documentation
Input range0 V to 2 V linear, high impedance, fixed gain 1 V per V
Input resistance1 gigohm typical, so a divider in the megohm range is not loaded
Offset errorPlus or minus 9.9 mV maximum on the base grade, plus or minus 1.5 mV on the B grade
Offset driftPlus or minus 20 microvolt per C typical on the base grade, 10 maximum on the B grade
Gain errorPlus or minus 1 percent maximum on the base grade, plus or minus 0.2 percent on the B grade
Nonlinearity0.04 percent maximum on the base grade
OutputDifferential, centred at 1.44 V, clipping at 2.49 V, with a minus 2.5 V failsafe level
Common mode transient immunity15 kV per microsecond minimum on the base grade, 100 kV per microsecond on the B grade
SuppliesHigh side 4.5 to 5.5 V, low side 3.0 to 5.5 V, with missing high side supply detection
Isolation5000 V RMS for one minute per UL1577, 7000 V peak reinforced per VDE 0884-17, working voltage 1500 V RMS
BodySOIC DWV eight pins
Order code factsAMC1311QDWVRQ1, 1000 pieces on a large reel, moisture level 3 with a 168 hour floor life, marking 1311Q1, with a 64 piece tube row for prototypes
Where it is usedTraction inverter voltage sensing, on board charger input monitoring, battery pack voltage measurement and DC to DC converter supervision

The table above is read from the vendor document, not from a distributor summary. Where a window is printed, the window is what a production test should use, and the typical value is only a starting point for the first article.

Where the numbers matter in a real build

Traction inverter work is where this part earns its qualification. A 400 V or 800 V bus has to be measured on the low voltage side for the control loop and for protection, and the divider that touches the bus is a high impedance source that cannot drive a buffer without loading itself. The high impedance input lets the divider be built for standoff, and the reinforced barrier gives the isolation the vehicle safety file requires. The grade 1 temperature range covers the under hood environment without a separate part number.

The two grades inside the same code family are the practical trap in a bill of materials. The base AMC1311 grade carries 9.9 mV of offset and 15 kV per microsecond of transient immunity, and the B grade carries 1.5 mV and 100 kV per microsecond. Both are automotive qualified and both ship in the same body, and the marking on the reel is the only visible difference. A traction inverter with a fast switching stage usually needs the B grade, and a specification that copies the base grade from an older program leaves the transient immunity three times lower than the stage demands.

Functional safety documentation is a deliverable, not a datasheet appendix. The vendor supplies a safety manual and an analysis report for this family, and those documents are what a system integrator needs to claim a diagnostic coverage figure for the isolation barrier and for the measurement channel. A program that buys the part without the documents ends up recomputing the failure rates from scratch, which is weeks of work that the qualification file already contains.

Missing high side supply detection matters more in a vehicle than in an industrial drive, because the failure has to be reported to the driver and stored for service. When the isolated supply collapses, the output goes to its failsafe level rather than drifting, and the controller can distinguish a failed measurement from a genuine zero volt bus. That distinction is what a diagnostic trouble code depends on, and it is the difference between a warranty claim that can be diagnosed and one that cannot.

  • Divider ratio and standoff on the actual board, measured after assembly rather than computed only.
  • Offset and gain at 25 C on the first article, with the input shorted at the high side.
  • Output level with the high side supply removed, against the level the diagnostic expects.
  • Transient response at the switching edge, with the dv/dt of the actual traction stage.
  • Creepage and clearance for the DWV body, against the vehicle isolation file.
  • Marking and grade check on the reel, since the base and B grades share a body.

Which projects this part fits

This part fits traction inverter bus voltage sensing, on board charger input monitoring, battery pack and cell module voltage measurement, DC to DC converter supervision and auxiliary inverter control in electric and hybrid vehicles. It also appears in charging station equipment and in automotive test hardware where the qualification file has to match the vehicle. For customers building automotive power electronics, the B grade is the usual selection for a fast switching stage, and the base grade is for a slower stage or a monitoring channel with a relaxed error budget.

Questions that come up before a purchase order is released

Can an industrial AMC1311 be substituted in a prototype?

For bench work, yes, provided the grade difference is understood: the industrial part is not qualified to the same standard and its documentation package is different. For a verification build that will be submitted for qualification, the automotive part has to be in place from the first build, because the qualification evidence follows the part number that was actually used.

What documents come with the automotive part?

The data sheet, the qualification summary and, on request, the functional safety manual and the failure mode analysis report. Those last two are what the system safety case cites, and they are released under a specific agreement rather than published on the product page. We can supply the document numbers and the route to request them.

Is the B grade a different part number?

Yes. The B grade carries its own code in the same body, and it is the one to order when the error budget or the transient immunity demands it. The two are pin compatible, so a board can carry either, and the firmware behaves the same because the transfer function and the output topology are the same.

How is the part tested on a production line?

The functional test is a supply current check on both sides, an offset check with the input grounded, and a transfer check through the barrier with a known input. A high voltage barrier test belongs to the qualification and audit plan rather than to every unit. The automotive line also keeps lot traceability, which is what a recall investigation needs.

Does the automotive grade change the isolation rating?

No. The barrier rating is the same 5000 V RMS and 7000 V peak, and the working voltage is the same 1500 V RMS. What changes is the qualification evidence behind those numbers and the temperature grade over which they are guaranteed. A customer who needs a higher working voltage steps to a different body rather than to the automotive suffix.

How SUPERB handles this line

We supply the AMC1311QDWVRQ1 from original reels with lot traceability and confirm the grade marking on arrival, because the base and B grades share a body and a pinout. The power management cross reference page lists the isolated measurement families with their automotive members, ADC and DAC cross reference covers the converters that read the differential output, and supplier quality audit sets out what we ask a channel to prove before an automotive part is quoted against a production schedule.