Contact Us

PFC Controllers for AC-DC Front Ends

Active power factor controllers for boost stages in AC-DC front ends. Continuous conduction mode parts hold a fixed frequency from 18 kHz to 250 kHz. Critical conduction mode parts cover adapters and ballasts up to about 350 W. Average current control, brown out detection and open loop protection on chip.
quote now

Product Specifications

Product Overview

An AC-DC front end draws current in narrow pulses at the crest of the line unless something shapes it. A capacitor input rectifier gives a power factor near 0.6 and a current waveform full of harmonics, which fails the harmonic limits that most markets apply above 75 W. An active power factor stage puts a boost converter between the bridge and the bulk capacitor, and forces the input current to follow the line voltage, which brings the power factor to 0.99 and the current distortion down to a few percent.

The controller decides how that boost stage behaves. In continuous conduction mode the inductor current never reaches zero, the switching frequency is fixed, and the topology suits 300 W to several kW because the peak current is close to the average. The UCC28180 runs at any frequency from 18 kHz to 250 kHz set by one resistor, drives the gate with 1.5 A source and 2 A sink, holds a maximum duty cycle of 96 percent and needs no line sensing, all in an eight pin package. The NCP1654 fixes the frequency at 65 kHz, 133 kHz or 200 kHz depending on the version, and the ICE3PCS01G covers 21 kHz to 250 kHz with an internal 2.5 V reference and a brown out detector.

In critical conduction mode the inductor current falls to zero before the next cycle starts, so the diode has no reverse recovery loss and the switch turns on at zero current. That is the cheapest way to reach a power factor above 0.9 in the 50 W to 350 W range, and the NCP1608 does it in a SOIC-8 with a 500 mA source and 800 mA sink driver, a 2.5 V reference trimmed to 1.6 percent, a startup current below 35 microamps and overvoltage, undervoltage, open loop and cycle by cycle current limits on board.

Key Specifications

ParameterContinuous conduction modeCritical conduction mode
Typical power300 W to several kW50 W to about 350 W
Switching frequencyFixed, 18 kHz to 250 kHz programmable on UCC28180 and ICE3PCS01G; 65 kHz, 133 kHz or 200 kHz on NCP1654Variable with the line and the load, set by the inductor and the on time
Control schemeAverage current mode with a fixed rampConstant on time, voltage mode
Gate drive1.5 A source and 2 A sink on UCC28180; 500 mA source and 800 mA sink on NCP1608Source 500 mA, sink 800 mA on NCP1608
Line sensingNot required on UCC28180 and NCP1608; brown out detection on ICE3PCS01GNot required, the on time follows the control voltage
Maximum duty cycle96 percent on UCC28180, 95 percent on ICE3PCS01GLimited by the inductor reset, not by the controller
ReferenceInternal, trimmed; 2.5 V plus or minus 1.2 percent on ICE3PCS01G2.5 V plus or minus 1.6 percent on NCP1608
ProtectionSoft overcurrent, peak current limit, output overvoltage with hysteresis, open loopOvervoltage, undervoltage, open loop, cycle by cycle current limit
Package8 pin SOIC, 14 pin DSO8 pin SOIC

Included Models and Order Codes

The codes below cover adapters, LED drivers, telecom rectifiers and motor drives with a power factor stage. State the output power, the line range, the bulk voltage, the switching frequency and the gate charge of the switch, and the part and the frequency version are confirmed.

Part NumberModeSwitching FrequencyDrivePackage
UCC28180DContinuous conduction18 kHz to 250 kHz, set by one resistor1.5 A source, 2 A sinkSOIC-8
UCC28180DRContinuous conduction18 kHz to 250 kHz, set by one resistor1.5 A source, 2 A sinkSOIC-8, tape and reel
UCC28019ADContinuous conduction65 kHz fixed1.5 A source, 2 A sinkSOIC-8
NCP1654BD65R2GContinuous conduction65 kHz fixed1.5 A source, 2 A sinkSOIC-8
NCP1654BD133R2GContinuous conduction133 kHz fixed1.5 A source, 2 A sinkSOIC-8
ICE3PCS01GContinuous conduction21 kHz to 250 kHz, external sync 50 kHz to 150 kHz1.5 A source, 2 A sinkDSO-14
NCP1608BDR2GCritical conductionFollows the inductor and the line500 mA source, 800 mA sinkSOIC-8

Key Features

Frequency set by one resistor – the UCC28180 and the ICE3PCS01G take the switching frequency from a single resistor, so one board can be tuned for a small inductor at 250 kHz or a larger one at 65 kHz without a new part.

No line sensing network – the UCC28180 and the NCP1608 derive the current shape from the duty cycle and the error amplifier, which removes the rectified line divider and its tolerance from the bill.

Driver sized for the switch – 1.5 A source and 2 A sink on the continuous mode parts turns a 60 milliohm superjunction FET in tens of nanoseconds, which is where the switching loss of a 3 kW stage is decided.

Brown out and open loop protection – the ICE3PCS01G detects a low line and an open feedback loop and restarts softly, so a line sag does not leave the bulk capacitor charged with the control loop saturated.

Duty cycle to 95 percent – a wide duty range keeps the boost stage in regulation when the input is at the low end of a wide range line, which is the case for 85 V to 265 V adapters.

Critical mode without a sense winding divider – the NCP1608 uses a zero current detection winding and a constant on time, so a 150 W adapter reaches a power factor near unity with a small inductor and no reverse recovery loss.

Applications

These controllers are quoted for offline supplies that have to meet a harmonic limit, typically where: A power factor stage is quoted with the SUPERB PCB and the SUPERB PCBA build for the same supply, so the current sense resistor and the gate loop are reviewed with the controller.

Telecom and server rectifiers – a 1 kW to 3 kW rectifier runs a continuous mode stage at 65 kHz to 100 kHz with a bulk voltage near 390 V, and the average current loop has to hold the distortion low at light load too.

LED drivers and outdoor supplies – a 150 W to 300 W driver uses critical mode so that the inductor and the diode stay small, and the wide duty range covers a 90 V to 305 V line.

Motor drives and appliance inverters – a drive with a DC link needs a power factor stage in front of it, and the controller has to survive the line dips that come with the same contactor that starts the motor.

Sourcing and Cross-Reference

Power factor controllers are replaced for availability and for efficiency, and the two rarely point at the same part. A drop in replacement has to match the control scheme, the frequency setting, the reference voltage, the gate drive current and the protection set, because a part that changes from average current mode to peak current mode will change the input current shape at the crossover and can fail the harmonic limit that the original part passed. We quote the mode, the frequency range, the drive current, the reference tolerance and the package on every line.

Around the controller, the inductor, the current sense resistor, the bulk capacitor and the boost diode set the loss and the thermal rise, so a change of frequency moves the loss between the switch and the inductor. Where a part is being replaced for efficiency, the new frequency and the inductor are quoted as one set, and the current sense threshold is checked against the resistor that is already on the board.

For boards that mix a controller, a gate driver and a 600 V switch, SUPERB Assembly support covers the reflow and the inspection of the high voltage spacing after cleaning.

Q: Can you supply a power factor controller that keeps the same frequency setting and drive current?

A: Yes. Send the output power, the line range, the switching frequency and the gate charge, and the SUPERB Tech sales team will confirm the order code and the nearest part that keeps the same control scheme.

Why Buyers Source PFC Controllers Through SUPERB

  1. Control scheme on the quote: average current or constant on time is stated per line, so a replacement does not change the input current shape.
  2. Frequency and drive matched: the frequency setting method and the gate drive current are confirmed, so the switch and the inductor stay inside their loss budget.
  3. Passives quoted with the controller: the inductor, the sense resistor and the boost diode are quoted as one set, so the thermal numbers belong to parts that will be fitted.
  4. High voltage assembly support: 600 V spacing and creepage are checked on the assembled board, not only in the netlist.

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Power management ICs, PWM controllers for switching supplies, Gate driver chips, Power MOSFETs, BOM shortage recovery.