Contact Us
  • Home
  • COMPONENTS
  • Load Switches and Hot Swap Controllers for Board Power Sequencing

Load Switches and Hot Swap Controllers for Board Power Sequencing

Integrated load switches from 1 V to 5.5 V and 1.5 A to 6 A. On resistance from 16 milliohm to 90 milliohm with quiescent current in microamps. Hot swap controllers from 2.9 V to 80 V with programmable current limit and fault timer. Adjustable slew rate, reverse current blocking and power good outputs.
quote now

Product Specifications

Product Overview

Two different problems are solved by the same idea. A load switch disconnects a subcircuit from a rail under software control, so a radio, a display or a sensor block can be powered down between measurements instead of being left on a always on rail. A hot swap controller does the same thing while the board is being inserted into a live backplane, where the problem is not the steady state current but the inrush into the decoupling capacitance and the energy that the pass device has to absorb while it does so. The first is chosen on on resistance and quiescent current; the second on safe operating area and current limit accuracy.

The integrated switches here run from the TPS22918 at 2 A and 52 milliohm with 8.3 microamps of quiescent current, through the TPS22917 at a lower quiescent current, to the TPS22965 at 6 A and 16 milliohm. All three offer a controlled rise time through a capacitor on the CT pin, which is what keeps a 100 microfarad load from pulling the rail down when it is switched on, and all three block reverse current when the output is above the input, which matters when a rail is back fed from a battery or from a second supply.

The hot swap group starts at the LTC4234, which integrates the controller, the pass MOSFET and the sense resistor in one 5 by 9 mm package, guarantees the safe operating area at 81 W for 30 ms and holds an 11 percent accurate current limit around 22.5 A, on a 2.9 V to 15 V rail. The LM5069 moves to 9 V to 80 V with an external MOSFET, a programmable power limit and a circuit breaker, which is the shape used on 48 V telecom and industrial backplanes. Between them they cover the two ends of the range: a plug in card at 12 V, and a 48 V line card with a fault timer.

Key Specifications

ParameterIntegrated load switchesHot swap controllers
Input range1 V to 5.5 V2.9 V to 15 V integrated, 9 V to 80 V with an external MOSFET
Current1.5 A to 6 A continuous10 A and 20 A integrated, higher with an external device
On resistance16 milliohm to 90 milliohm at 5 V4 milliohm including the sense resistor on the LTC4234
Current limitInternal, fixed per part numberAdjustable, 11 percent accurate on the LTC4234
Inrush controlRise time set by a capacitor on CTProgrammable slew rate and power limit
Fault behaviourThermal shutdown, reverse current blockingFault timer, circuit breaker, latch or auto retry
MonitoringNone, switch onlyCurrent and temperature monitor outputs, power good
Quiescent current8.3 microamps typical on the TPS229181.6 mA with the pass device on
PackageSOT-23-6 and WSON-8MSOP-10 and QFN

Included Models and Order Codes

The table lists the switch and controller order codes most often quoted for sequencing and live insertion. State the rail voltage, the steady state and inrush current, whether the pass device is integrated, and the fault behaviour the system expects, and the order code is confirmed with packing.

Part NumberFunctionInput RangeCurrentOn ResistancePackage
TPS22918DBVRLoad switch with adjustable rise time and quick output discharge1 V to 5.5 V2 A52 milliohm at 5 VSOT-23-6
TPS22917DBVRLoad switch with low quiescent current1 V to 5.5 V2 A80 milliohm typicalSOT-23-6
TPS22965DSGRLoad switch for high current rails0.5 V to 5.7 V6 A16 milliohm at 5 VWSON-8
TPS259571DSGRIntegrated fuse with adjustable current limit2.7 V to 5.7 V4 A28 milliohm typicalWSON-10
LM5069MM-1Hot swap controller with power limiting, latched fault9 V to 80 VSet by the external MOSFETExternal deviceMSOP-10
LM5069MM-2Same controller with automatic restart9 V to 80 VSet by the external MOSFETExternal deviceMSOP-10
LTC4234CWHH#PBFHot swap controller with integrated MOSFET and sense resistor2.9 V to 15 V20 A, 22.5 A current limit4 milliohm including senseQFN-38
LTC4233CWHH#PBF10 A version of the same integrated controller2.9 V to 15 V10 A4 milliohm including senseQFN-38
ADM1278-1ACPZHot swap controller with PMBus monitoring4.5 V to 20 VSet by the external MOSFETExternal deviceLFCSP

Key Features

On resistance stated at the working rail – 52 milliohm at 5 V and 16 milliohm at 5 V are the numbers that decide the drop and the dissipation, and they are quoted at the voltage the rail actually uses.

Rise time set by one capacitor – the CT pin sets the output slew, so the inrush into a large decoupling bank is a number on the bench rather than a guess.

Reverse current blocking – when the output is held above the input by a battery or a second source, the switch stays off instead of conducting through the body diode.

Quiescent current in microamps – 8.3 microamps on the TPS22918 keeps a always on switch from being the dominant load on a battery instrument.

Safe operating area guaranteed – the LTC4234 is production tested for the hot swap stress, so the pass device does not have to be derated from a generic curve.

Programmable power limit – the LM5069 sets the maximum dissipation in the external MOSFET, which is what keeps a 48 V card inside its device rating during a long inrush.

Applications

These parts are quoted for power sequencing and live insertion, typically where: A sequencing or hot swap section is normally quoted with the SUPERB PCB and SUPERB PCBA work we support for the same card, so the switches, the controllers and the assembly arrive together.

Battery instruments with subcircuit power down – a radio, a display or a sensor block is switched off between measurements and the switch has to add microamps, not milliamps, to the standby budget.

Plug in cards on a live backplane – a 12 V or 48 V card is inserted while the bus is powered, and the inrush into the input capacitance has to stay inside the connector rating.

Redundant and ORed rails – two supplies feed one rail and the switch blocks reverse current when one of them is removed, without a separate ideal diode controller.

Sourcing and Cross-Reference

Load switches are chosen on numbers that are easy to compare and hard to substitute: on resistance at the working voltage, quiescent current, rise time control and reverse blocking. Parts in the same family differ in exactly those, and a swap made on the current rating alone usually shows up as a higher standby current or a rail that dips when a load is switched on. We quote the full order code and state the on resistance and quiescent current on the confirmation.

On hot swap controllers the pass device and the sense resistor are part of the specification. The integrated LTC4234 and LTC4233 remove both from the BOM and from the safe operating area calculation; the LM5069 keeps them external, which is what a 48 V card needs because the MOSFET has to be chosen against the actual load. Where a board is being re-spun from an older controller, we state which pins move and whether the fault timer components can stay.

Where the cards are built in volume, SUPERB Assembly support covers the SMT build of the power entry and sequencing sections.

Q: Can you supply the load switch and the hot swap controller against the exact order code on the BOM?

A: Yes. Send the complete order code, the rail voltage and the inrush current, and the SUPERB Tech sales team will confirm availability and whether the integrated or the external MOSFET version is in stock.

Why Buyers Source Power Switching Through SUPERB

  1. Numbers on the quote: on resistance, quiescent current and current limit accuracy are stated per line, so a substitute can be judged instead of assumed.
  2. Integrated and discrete options: both the integrated controller and the external MOSFET route are quoted, so the choice is made on thermal and space grounds rather than on what happens to be listed.
  3. Fault behaviour matched to the system: latched and auto retry versions are treated as different parts and quoted separately, because the difference decides what an operator sees after a fault.
  4. Sequencing parts as one set: switches, supervisors and the DC-DC stages they sequence are quoted together, so the timing budget uses parts that will actually be fitted.

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Power management ICs, LDO linear regulators, PWM controllers, Power MOSFETs, Component lead time solutions.