Load Switches and Hot Swap Controllers for Board Power Sequencing
Product Specifications
Product Overview
Two different problems are solved by the same idea. A load switch disconnects a subcircuit from a rail under software control, so a radio, a display or a sensor block can be powered down between measurements instead of being left on a always on rail. A hot swap controller does the same thing while the board is being inserted into a live backplane, where the problem is not the steady state current but the inrush into the decoupling capacitance and the energy that the pass device has to absorb while it does so. The first is chosen on on resistance and quiescent current; the second on safe operating area and current limit accuracy.
The integrated switches here run from the TPS22918 at 2 A and 52 milliohm with 8.3 microamps of quiescent current, through the TPS22917 at a lower quiescent current, to the TPS22965 at 6 A and 16 milliohm. All three offer a controlled rise time through a capacitor on the CT pin, which is what keeps a 100 microfarad load from pulling the rail down when it is switched on, and all three block reverse current when the output is above the input, which matters when a rail is back fed from a battery or from a second supply.
The hot swap group starts at the LTC4234, which integrates the controller, the pass MOSFET and the sense resistor in one 5 by 9 mm package, guarantees the safe operating area at 81 W for 30 ms and holds an 11 percent accurate current limit around 22.5 A, on a 2.9 V to 15 V rail. The LM5069 moves to 9 V to 80 V with an external MOSFET, a programmable power limit and a circuit breaker, which is the shape used on 48 V telecom and industrial backplanes. Between them they cover the two ends of the range: a plug in card at 12 V, and a 48 V line card with a fault timer.
Key Specifications
| Parameter | Integrated load switches | Hot swap controllers |
|---|---|---|
| Input range | 1 V to 5.5 V | 2.9 V to 15 V integrated, 9 V to 80 V with an external MOSFET |
| Current | 1.5 A to 6 A continuous | 10 A and 20 A integrated, higher with an external device |
| On resistance | 16 milliohm to 90 milliohm at 5 V | 4 milliohm including the sense resistor on the LTC4234 |
| Current limit | Internal, fixed per part number | Adjustable, 11 percent accurate on the LTC4234 |
| Inrush control | Rise time set by a capacitor on CT | Programmable slew rate and power limit |
| Fault behaviour | Thermal shutdown, reverse current blocking | Fault timer, circuit breaker, latch or auto retry |
| Monitoring | None, switch only | Current and temperature monitor outputs, power good |
| Quiescent current | 8.3 microamps typical on the TPS22918 | 1.6 mA with the pass device on |
| Package | SOT-23-6 and WSON-8 | MSOP-10 and QFN |
Included Models and Order Codes
The table lists the switch and controller order codes most often quoted for sequencing and live insertion. State the rail voltage, the steady state and inrush current, whether the pass device is integrated, and the fault behaviour the system expects, and the order code is confirmed with packing.
| Part Number | Function | Input Range | Current | On Resistance | Package |
|---|---|---|---|---|---|
| TPS22918DBVR | Load switch with adjustable rise time and quick output discharge | 1 V to 5.5 V | 2 A | 52 milliohm at 5 V | SOT-23-6 |
| TPS22917DBVR | Load switch with low quiescent current | 1 V to 5.5 V | 2 A | 80 milliohm typical | SOT-23-6 |
| TPS22965DSGR | Load switch for high current rails | 0.5 V to 5.7 V | 6 A | 16 milliohm at 5 V | WSON-8 |
| TPS259571DSGR | Integrated fuse with adjustable current limit | 2.7 V to 5.7 V | 4 A | 28 milliohm typical | WSON-10 |
| LM5069MM-1 | Hot swap controller with power limiting, latched fault | 9 V to 80 V | Set by the external MOSFET | External device | MSOP-10 |
| LM5069MM-2 | Same controller with automatic restart | 9 V to 80 V | Set by the external MOSFET | External device | MSOP-10 |
| LTC4234CWHH#PBF | Hot swap controller with integrated MOSFET and sense resistor | 2.9 V to 15 V | 20 A, 22.5 A current limit | 4 milliohm including sense | QFN-38 |
| LTC4233CWHH#PBF | 10 A version of the same integrated controller | 2.9 V to 15 V | 10 A | 4 milliohm including sense | QFN-38 |
| ADM1278-1ACPZ | Hot swap controller with PMBus monitoring | 4.5 V to 20 V | Set by the external MOSFET | External device | LFCSP |
Key Features
On resistance stated at the working rail – 52 milliohm at 5 V and 16 milliohm at 5 V are the numbers that decide the drop and the dissipation, and they are quoted at the voltage the rail actually uses.
Rise time set by one capacitor – the CT pin sets the output slew, so the inrush into a large decoupling bank is a number on the bench rather than a guess.
Reverse current blocking – when the output is held above the input by a battery or a second source, the switch stays off instead of conducting through the body diode.
Quiescent current in microamps – 8.3 microamps on the TPS22918 keeps a always on switch from being the dominant load on a battery instrument.
Safe operating area guaranteed – the LTC4234 is production tested for the hot swap stress, so the pass device does not have to be derated from a generic curve.
Programmable power limit – the LM5069 sets the maximum dissipation in the external MOSFET, which is what keeps a 48 V card inside its device rating during a long inrush.
Applications
These parts are quoted for power sequencing and live insertion, typically where: A sequencing or hot swap section is normally quoted with the SUPERB PCB and SUPERB PCBA work we support for the same card, so the switches, the controllers and the assembly arrive together.
Battery instruments with subcircuit power down – a radio, a display or a sensor block is switched off between measurements and the switch has to add microamps, not milliamps, to the standby budget.
Plug in cards on a live backplane – a 12 V or 48 V card is inserted while the bus is powered, and the inrush into the input capacitance has to stay inside the connector rating.
Redundant and ORed rails – two supplies feed one rail and the switch blocks reverse current when one of them is removed, without a separate ideal diode controller.
Sourcing and Cross-Reference
Load switches are chosen on numbers that are easy to compare and hard to substitute: on resistance at the working voltage, quiescent current, rise time control and reverse blocking. Parts in the same family differ in exactly those, and a swap made on the current rating alone usually shows up as a higher standby current or a rail that dips when a load is switched on. We quote the full order code and state the on resistance and quiescent current on the confirmation.
On hot swap controllers the pass device and the sense resistor are part of the specification. The integrated LTC4234 and LTC4233 remove both from the BOM and from the safe operating area calculation; the LM5069 keeps them external, which is what a 48 V card needs because the MOSFET has to be chosen against the actual load. Where a board is being re-spun from an older controller, we state which pins move and whether the fault timer components can stay.
Where the cards are built in volume, SUPERB Assembly support covers the SMT build of the power entry and sequencing sections.
Q: Can you supply the load switch and the hot swap controller against the exact order code on the BOM?
A: Yes. Send the complete order code, the rail voltage and the inrush current, and the SUPERB Tech sales team will confirm availability and whether the integrated or the external MOSFET version is in stock.
Why Buyers Source Power Switching Through SUPERB
- Numbers on the quote: on resistance, quiescent current and current limit accuracy are stated per line, so a substitute can be judged instead of assumed.
- Integrated and discrete options: both the integrated controller and the external MOSFET route are quoted, so the choice is made on thermal and space grounds rather than on what happens to be listed.
- Fault behaviour matched to the system: latched and auto retry versions are treated as different parts and quoted separately, because the difference decides what an operator sees after a fault.
- Sequencing parts as one set: switches, supervisors and the DC-DC stages they sequence are quoted together, so the timing budget uses parts that will actually be fitted.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Power management ICs, LDO linear regulators, PWM controllers, Power MOSFETs, Component lead time solutions.