Battery Chargers and Fuel Gauges for Portable Instruments
Product Specifications
Product Overview
A portable instrument has three power jobs that are usually three separate parts: charging the cell, deciding how much charge is left, and keeping the system alive while the cell is flat. On a handheld meter the charger is a linear part because the input is a 5 V adapter and the cell is one lithium cell; on a battery pack with a 12 V or 20 V input the charger is a switch mode stage because the dissipation of a linear part at 2 A would need a heatsink that does not fit. The gauge is a separate decision again: a voltage model gauge needs no sense resistor and no learning cycle, a coulomb counting gauge needs a 10 milliohm shunt but holds its accuracy when the load profile is unknown.
The linear group on this page runs from the MCP73831 and TP4056 at 500 mA and 1 A, through the LTC4054, to the BQ24075 and BQ24074, which add power path control so the system stays powered from the adapter while the cell charges and switches over without a glitch when the adapter is removed. The switch mode group starts at the BQ25606 and BQ25895 at 3 A and 5 A with I2C control of the input current limit, the charge current and the termination threshold, which is what a USB-C input needs because the available current is negotiated rather than fixed.
On the gauge side the MAX17048 uses a voltage model and no sense resistor, draws 3 microamps in hibernate and reports state of charge, voltage and rate over I2C, which suits a sealed handheld where a shunt would cost more than the gauge. The BQ27441-G1 uses impedance tracking with a 10 milliohm sense resistor and reports remaining capacity in mAh, state of charge and state of health, which suits a pack that is cycled hard and where the user expects the percentage to hold under load. The BQ34Z100 extends the same approach to multi cell packs and to chemistries other than lithium ion.
Key Specifications
| Parameter | Linear chargers | Switch mode chargers | Fuel gauges |
|---|---|---|---|
| Input voltage | 4.35 V to 6.5 V, 28 V tolerant on the BQ2407x | 3.9 V to 14 V with input current limit | 2.5 V to 4.5 V cell supply |
| Charge current | 500 mA to 1.5 A | 2 A to 5 A with I2C setting | Not applicable |
| Cell count | One cell | One cell | One cell, two cells and multi cell packs |
| Topology | Linear, with power path on the BQ2407x | Synchronous buck, 1.5 MHz switching | Voltage model or coulomb counting |
| Accuracy | Plus or minus 0.5 percent voltage regulation on the BQ2407x | Plus or minus 0.5 percent voltage and plus or minus 5 percent current regulation | Reported state of charge with 7.5 mV per cell voltage measurement |
| Termination | Current threshold set by a resistor | I2C programmable, with recharge threshold | Not applicable |
| Interface | Status pins, no bus needed | I2C for current limit, voltage and status | I2C at 400 kHz, alert output |
| Quiescent current | Tens of microamps in standby | Tens of microamps in ship mode | 3 microamps hibernate, 23 microamps active on the MAX17048 |
| Package | SOT-23, SOP-8 and QFN | QFN and WQFN | TDFN, SON and WLP |
Included Models and Order Codes
The table lists the charger and gauge order codes quoted most often for handheld instruments. State the cell chemistry and capacity, the input source and its current limit, and whether the gauge must work without a sense resistor, and the order code is confirmed with packing.
| Part Number | Function | Charge Current | Input | Interface | Package |
|---|---|---|---|---|---|
| BQ24075RGTR | Linear charger with power path and input current limit | 1.5 A | USB or adapter up to 6.5 V | Status pins | QFN |
| BQ24074RGTR | Same family with adjustable termination and sys output | 1.5 A | USB or adapter up to 6.5 V | Status pins | QFN |
| BQ25895RTWR | Switch mode charger with MaxCharge and boost mode | 5 A | 3.9 V to 14 V | I2C | WQFN |
| BQ25606RGER | Standalone switch mode charger for USB input | 3 A | 4 V to 13.5 V | Status pins | QFN |
| TP4056 | Linear charger, constant current constant voltage | 1 A | 4.5 V to 5.5 V | Status pins | SOP-8 |
| MCP73831T-2ACI/OT | Linear charger for small cells | 500 mA | 3.75 V to 6 V | Status pin | SOT-23 |
| LTC4054ES5-4.2#PBF | Linear charger with thermal regulation | 800 mA | 4.25 V to 6.5 V | Status pin | SOT-23 |
| BQ27441DRZR-G1A | Impedance tracking fuel gauge with sense resistor | Not applicable | Single cell | I2C | SON |
| MAX17048G+T10 | Voltage model fuel gauge without sense resistor | Not applicable | Single cell | I2C | TDFN |
| BQ34Z100PWR-G1 | Fuel gauge for multi cell packs and several chemistries | Not applicable | Up to 16 series cells with a divider | I2C | TSSOP |
| LTC2944IDD#PBF | Coulomb counter with voltage and temperature | Not applicable | Up to 60 V rail | I2C | DFN |
Key Features
Power path keeps the system alive – on the BQ2407x the system rail is fed from the adapter while the cell charges and from the cell when the adapter is removed, so a meter does not reboot when it is plugged in.
Input current limit that matches the source – the USB input limit is set by a resistor or by I2C, so a 500 mA port is not asked for 1 A and a weak adapter does not collapse the rail.
Thermal regulation instead of shutdown – the linear parts fold the charge current back as the junction heats, which keeps a sealed handheld charging rather than cycling on the thermal trip.
Gauge without a sense resistor – the MAX17048 needs no shunt and no learning cycle, which removes a component and a production step from a low cost instrument.
Gauge with coulomb counting – the BQ27441 holds state of charge under a load profile that a voltage model cannot follow, and reports state of health as the cell ages.
Status and interrupts – charge, done and fault are available as pins or as I2C status bits, so the firmware can show the real state instead of a timer driven guess.
Applications
These parts are quoted for battery powered instruments, typically where: A pack or a handheld board is normally quoted with the SUPERB PCB and SUPERB PCBA work we support for the same product, so the charger, the gauge and the assembly are handled as one order.
Handheld test meters – a single cell, a 5 V USB input and a display that must show a percentage the user trusts after two years of partial cycles.
Portable medical and monitoring devices – power path control so the device keeps running while charging, with termination and fault status available to the host.
Field data loggers and trackers – a solar or 12 V input, a switch mode charger and a gauge that survives a load profile with long sleep periods and short transmit bursts.
Sourcing and Cross-Reference
Charger and gauge orders depend on details that the family name hides: the input voltage rating, whether the part is standalone or I2C controlled, and the packing. The BQ24075 and BQ24074 share a body and a pinout but differ in termination behaviour, and the BQ27441 has several firmware variants under one base part number. We quote the full string and confirm the variant on the confirmation rather than after the reels arrive.
Where a pack is being moved from an older charger, the useful step is to keep the sense resistor and the thermistor network unchanged and change only the controller. That is possible across most of the BQ24xxx and BQ25xxx range and across the MAX1704x gauges, and it keeps the existing production test fixture valid. When the change cannot keep the footprint, we say which pins move and what the test fixture has to check.
Where the boards are assembled in volume, SUPERB Assembly support covers the SMT build of the power and charging section.
Q: Can you supply the charger and the fuel gauge from the same pack BOM in one shipment?
A: Yes. Send the complete order code and the variant letter or suffix, state the cell capacity and the input source, and the SUPERB Tech sales team will confirm availability and the packing.
Why Buyers Source Charging and Gauging Through SUPERB
- Variant level quoting: the base part number usually covers several firmware and packing variants; the quote and the delivery note carry the exact one.
- Charger and gauge together: both lines of a pack BOM are quoted as one set, so the current limit of the charger and the sense resistor of the gauge are checked against each other before the build.
- Evaluation quantities: small quantities for a first prototype and reels for production come from the same source, which keeps the firmware validated on the same silicon as the build.
- Documentation for the pack file: date code, lot and country of origin are recorded per reel for the battery pack documentation that shipping and customs ask for.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Power management ICs, LDO linear regulators, Step down DC-DC converters, Component lead time solutions, Logic level shifters and IO expanders.