Contact Us

HXN50121

Brand: Hisiwell
Hisiwell HXN50121 is a discrete semiconductors component designed for DC-DC Converters & Power Supplies and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

HXN50121 — Discrete & Power Semiconductors | Superb Automation

HXN50121

Hisiwell — Discrete & Power Semiconductors

Product Overview

The HXN50121 from Hisiwell is a discrete power semiconductor delivering efficient switching and power conversion. Hisiwell is a recognized semiconductor supplier providing reliable components for global electronics manufacturing.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • Low Rds(on) for minimal conduction losses in power switching
  • Fast switching speed with low gate charge for high-frequency operation
  • Avalanche-rated for robust operation under inductive load conditions
  • High junction temperature rating for demanding environments
  • Logic-level gate drive compatible for simplified design
  • RoHS and AEC-Q101 qualified options available

Key Specifications

Vds / VceV
Id / IcA
Rds(on) / Vce(sat)mΩ
QgnC
Technology—
Package—
Configuration—
Mounting—

Applications

Switch-Mode Power Supplies Motor Drives & Inverters Battery Management Systems DC-DC Converters Load Switching Automotive Power Distribution

Request Quote — In Stock, 100% New & Original, Full Warranty

HXN50121: 100 W from DC to 3 GHz, and the mode claim that comes with it

The HXN50121 is a 100 W gallium nitride HEMT on the Hisiwell 50 V shelf with a DC to 3 GHz window and a continuous wave index row. Its description adds something the neighbours do not: the vendor states that it supports continuous wave, pulsed continuous wave and any other modulated signal, in saturated or backed off conditions. That sentence is the most useful thing published about this part.

100 W is 50.00 dBm exactly, which is the roundest number on the shelf and also a useful reference point: every other row can be measured against it without a calculator. The 130 W HXN50122 is 1.14 dB above it, the 140 W HXN50124 is 1.46 dB above it, and the 240 W HXN50126 is 3.80 dB above it.

What makes the mode sentence worth a paragraph is that a 3 GHz window on a 50 V rail normally means a cellular part, and cellular means modulated carriers with a crest factor. A vendor that states modulated operation explicitly is telling a buyer that the backed off condition is inside the intended use rather than outside the guarantee, and that is a different starting point from a part that only says continuous wave.

The HXN50121 rows as the vendor publishes them

Part classGallium nitride HEMT power transistor, single ended, unmatched
Frequency rangeDC to 3 GHz
Band width, calculated3,000 MHz
Saturation output, index row100 W
Saturation in dBm, calculated50.00 dBm
Output per gigahertz of band, calculated33.3 W per GHz
Drain rail, index row50 V
Mode, index rowContinuous wave
Mode, vendor descriptionContinuous wave, pulsed continuous wave and any modulated signal, saturated or backed off
MatchingUnmatched, no internal prematch stated
GainNot published on the index row
Drain efficiencyNot published on the index row
Peak and average outputNot published
Package and bodyNot published on the index row
Thermal resistance, junction to caseNot published
Gate bias point and quiescent currentNot published
Load impedance, source and loadNot published
Applied application listWireless communication infrastructure, wideband amplifier, EMC testing, industrial scientific and medical
Orderable addendum and packing dataNone published

The table is short and the missing rows are the usual three. On a 100 W part that is less painful than on a 280 W part, because the supply and the sink are ordinary hardware at this level and a wrong assumption costs less. It still costs something: without a gain figure, the drive requirement is open, and on an unmatched part without a load table the first board is a tuning exercise rather than a build.

The band is the reason this part exists on the shelf. Three gigahertz from DC covers the 2.4 GHz industrial band, the 2.7 GHz cellular band and the 3 GHz radar and instrumentation bands on one device, and the customer who needs a single amplifier covering all three cannot use the 2 GHz rows above it however much power they offer.

Current, heat and voltage at 100 W on 50 V

Drain efficiency assumedDC input, calculatedDrain current at 50 V, calculatedHeat at 100 W output, calculated
50 per cent200 W4.00 A100 W
55 per cent182 W3.64 A82 W
60 per cent167 W3.33 A67 W
65 per cent154 W3.08 A54 W
70 per cent143 W2.86 A43 W

Four amps at the worst corner is a supply a single regulator can hold, and that is what makes this row attractive for a product with several amplifiers in one box. The heat spread from 43 to 100 W is still large enough to decide the mechanical build, and with the efficiency blank the low end is the one to plan against until the sheet is read.

At the output, 100 W into 50 ohm is 70.7 V RMS and 100.0 V peak by calculation. A two to one mismatch takes the peak to 141.4 V. That is a comfortable region for the 200 V capacitor family and it is why the lower power rows on a 50 V shelf are often easier to certify than the higher ones: the same rail and half the watts means half the voltage stress at the port.

On a modulated carrier the backed off condition changes the arithmetic in one direction only. The average dissipation falls with the drive, but the peak envelope voltage at the port rises with the crest factor, so a 6 dB crest factor at 100 W peak means 25 W average, 3.5 A of drain current under a 50 per cent efficiency assumption, and a peak port voltage unchanged at 100 V. The supply is sized on the peak and the sink on the average, and the two use different numbers from the same table.

The 3 GHz window against its neighbours

HXN50121100 WDC to 3 GHzContinuous wave and modulated, as describedEntry row on the 3 GHz window
HXN50124140 WDC to 3 GHzContinuous wave1.46 dB more power, same window
HXN50131150 W per side, push-pullDC to 3 GHzContinuous waveCombined pair, different topology
HXN50141280 WDC to 3 GHzContinuous wave4.47 dB more power on the same window
HXN50122130 WDC to 2 GHzContinuous wave1.14 dB more power, 1 GHz less band
HX04200F200 W index, 219 W parameterDC to 4 GHzContinuous wave, 48 V rail3.01 dB more power, 1 GHz more band

The 3 GHz group has four members and they are not a simple ladder. The HXN50121 and the HXN50124 differ by 1.46 dB and by the mode wording, and the mode wording is the more important of the two. The HXN50131 is a push-pull part with 150 W per side, so its 300 W combined is a topology choice and not a power grade, and a customer comparing it to the single ended 280 W HXN50141 is comparing an even harmonic cancellation against 0.30 dB of output.

The HX04200F is the interesting alternative, because it covers one more gigahertz on a 48 V rail with a published gain and efficiency. A customer whose band stops at 4 GHz and who wants a documented part will reach for that one, and a customer who wants 50 V and a single row will stay here. The 1 GHz and the rail are the whole decision.

The cross reference for these rows is on the RF power transistor page, and the route to a measured sample before a build is on the RF component sourcing page.

Ordering and what to ask for

No orderable addendum, packing column, marking code or moisture level is published, and this page quotes none. The order should carry the part number, the band, the rail, the mode, the output point, the drive level expected and the quantity. Because the vendor describes modulated and backed off operation, the crest factor and the duty of the actual signal belong on the order as well, and leaving them off is how a part gets specified at the wrong operating point.

The load table is the highest value document to request, because the part is unmatched and the page publishes no source or load impedance. On a 3 GHz window the match is narrower than at 2 GHz, so a load pull at the frequency of use is not a luxury. First article tuning without it costs more bench hours than the request costs days.

Lead time is not published. The variables on a 50 V shelf part are the package and the test, and both are off the index row. Any date quoted before those two are answered is a placeholder and should be treated as one.

For a substitute at this band, the qualification path is on the one stop RF supply page, which covers what has to be re measured on the board.

Questions buyers ask about the HXN50121

Is the modulated operation a rating? The description says the part supports it. No backed off power figure is published with it, so the average level still has to be set from the thermal limit and the sheet rather than from the sentence.

Does 50.00 dBm mean exactly 100 W at 3 GHz? It means 100 W converted exactly. Where in the band that number holds is not stated, and on a 3 GHz window the top of the band is normally the first place a wattage falls.

Is it prematched? No prematch is stated for this part. The input and output networks are board work, and no impedance table is published on the page.

Why is the efficiency blank? The family omits gain and efficiency on the index for most members. It is not a withholding policy, it is an incomplete public table, and the sheet fills it.

Where the choice is between the 3 GHz window and the 2 GHz rows, the comparison belongs on the cross reference page with the band fixed first.