The LTM8046EY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LTM8046EY#PBF: An Isolated 5 V Rail From a 24 V Bus in a 9 mm by 15 mm Module
The LTM8046EY#PBF is an isolated flyback power module. The switching controller, the power switches, the transformer and the support components are inside a 9 mm by 15 mm by 4.92 mm BGA, the isolation rating is 2 kV AC with the module tested to 3 kV DC, and the part is recognised to UL 60950 under file E464570. Input range is 3.1 V to 31 V, output range is 1.8 V to 12 V set by one resistor, and the headline operating point is 5 V at 550 mA from a 24 V input. Current mode control, programmable soft start and a user configurable undervoltage lockout are included, and only input, output and bias capacitors are needed around it.
The reason to use a module here is the transformer. An isolated flyback built from discrete parts is a controller, a FET, a transformer, a optocoupler or a primary side sensing network and a compensation network, and the transformer is a custom magnetic that has to be qualified for the isolation rating. The module moves that qualification into a part number.
Five volts at 550 mA is 2.75 W, and the input current follows the efficiency
The output power is 2.75 W. From a 24 V input that is 143 mA at 80 percent efficiency, 153 mA at 75 percent and 135 mA at 85 percent. The spread between those three numbers is 18 mA, which is the difference between a comfortable input trace and a warm one, and it is why the efficiency curve of an isolated module has to be read at the actual operating point rather than at the headline.
The same 2.75 W at a 12 V set point is 229 mA. The output range of 1.8 V to 12 V is set by one resistor, so the module is a constant power source across that range and the current falls as the voltage rises. A system that needs 12 V at 550 mA is asking for 6.6 W and needs a different module, not a different resistor.
2 kV AC is 2828 V peak, and 3 kV DC is a different test
The isolation rating of 2 kV AC corresponds to 2828 V peak for a sine wave. The vendor also states the module is tested to 3 kV DC, which is a different waveform and a different stress: a dc test charges the barrier capacitance once and holds it, while an ac test drives it every cycle. Both figures describe the barrier and neither describes the continuous working voltage, which has to be taken from the safety standard the product is filed under.
The UL 60950 recognition under file E464570 is a component level recognition. It supports the system approval rather than replacing it, and a product that needs a reinforced rating has to check the creepage and clearance of the board around the module as well as the module itself.
The undervoltage lockout is user configurable, and that is the 24 V bus feature
A 24 V industrial bus sags during start-up and during load steps, and a module that starts at a fixed threshold can chatter. The configurable undervoltage lockout lets the board set the point at which the module begins to operate, with hysteresis from the same resistor network, so the isolated rail comes up after the bus is stable rather than during the dip.
Programmable soft start sets the ramp of the output, which controls the inrush into the isolated capacitance. Without it the module charges the output at its current limit and the input sees a step, which couples into the primary side through the shared input impedance.
| Function | Isolated flyback power module with the transformer inside the package |
| Input range | 3.1 V to 31 V |
| Output range | 1.8 V to 12 V, set by one resistor |
| Operating point | 5 V at 550 mA from 24 V, 2.75 W |
| Input current | 143 mA at 80 percent efficiency, 153 mA at 75 percent, 135 mA at 85 percent |
| Isolation | 2 kV AC rating, which is 2828 V peak, tested to 3 kV DC |
| Safety | UL 60950 recognised, file E464570 |
| Control | Current mode, programmable soft start, configurable undervoltage lockout |
| External parts | Input, output and bias capacitors only |
| Body | 9 mm by 15 mm by 4.92 mm BGA, SnPb or lead free finish |
Two questions buyers ask
Is 2 kV AC the working voltage of the barrier?
No. It is an isolation rating, and the vendor also states a 3 kV DC test. The continuous working voltage is the figure from the safety standard the product is approved against, and it is lower than either test value. A board specification that quotes the 2 kV AC rating as an operating voltage is quoting a withstand test.
Can two modules be put in series for a higher output?
The vendor documents series connection of isolated modules for higher output voltage, which works because each output is floating. The current stays at the rating of one module, so the series connection raises the voltage rather than the power, and the isolation of the second module stands on top of the first.
Ordering and supply
The EY suffix is the BGA body and PBF is the lead free finish. The same module is offered in a SnPb finish for lines still running tin lead, and the input and output ranges are fixed by the family rather than by the order suffix. The part is recommended for new projects at the vendor.
We hold this module for industrial and instrumentation builds. Start at the analog mixed signal ICs page, medical device components covers the isolation paperwork a medical build has to keep, and component lead time solutions is where a module with a long vendor lead time is planned into a build.
Request Quote — In Stock, 100% New & Original, Full Warranty