LTC4015EUHF#TRPBF
Product Specifications
LTC4015EUHF#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTC4015EUHF#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LTC4015EUHF battery charger controller with digital telemetry
The LTC4015EUHF is the E temperature letter of a multichemistry buck charger controller that charges Li-Ion, LiFePO4 or lead acid packs from 4.5 V to 35 V of input, with a battery ceiling of 35 V, pin selectable chemistry and charge voltage, and an I2C port that both sets and reports. The E letter is the grade code; the function is the same as the rest of the family.
What the 35 V ceilings allow
A 35 V input ceiling clears a 24 V rail at plus 10 percent, which is 26.4 V, by 8.6 V, so an industrial 24 V bus with a wide tolerance is inside the part. On the battery side the ceiling decides the series count: eight Li-Ion cells at 4.2 V is 33.6 V and fits, nine cells at 37.8 V does not. A 24 V lead acid pack at 28.8 V absorption is comfortable. The input ceiling is what an engineer checks first, because a charger that sits behind an unregulated adapter can see 30 V or more at light load.
Charge power and loss at three operating points
| Input | Battery | Charge | Output | Input power at 96 percent | Loss |
|---|---|---|---|---|---|
| 20 V | 25.2 V | 5 A | 126.0 W | 131.2 W | 5.25 W |
| 12 V | 12.6 V | 5 A | 63.0 W | 65.6 W | 2.62 W |
| 24 V | 25.2 V | 8 A | 201.6 W | 210.0 W | 8.40 W |
The loss row is the thermal question, and it belongs to the external FETs, the inductor and the sense resistors rather than to the controller. A 201.6 W charger at 8 A is a serious power stage: the 8.4 W of loss is spread over the synchronous FETs, and the current sense element that sets the charge current has to be sized for 8 A continuous with its own tolerance counted.
The telemetry numbers
The integrated 14-bit ADC with a coulomb counter reads battery voltage, battery current, battery resistance, the NTC ratio, input voltage, input current, system voltage and die temperature. Over a 35 V span a 14-bit reading is 2.136 mV per code, which is enough to see a cell balancing offset and not enough to certify a cell voltage; over a 2.5 V span the same converter is 152.6 uV per code, which is a different measurement entirely. Read the scaling per channel before quoting an accuracy figure, because the same 14 bits describe both.
What the digital side replaces
Safety timer, precharge, automatic recharge, termination and NTC protection are inside, and input current limit and charge current are set by sense resistors and then adjustable over I2C. MPPT and the input undervoltage current limit loop exist for a solar or a weak adapter input, and the ideal diode PowerPath plus instant-on operation means the system rail comes up with a fully discharged battery instead of waiting for a precharge cycle. Those features are what a host processor normally implements in firmware, and moving them into the charger is the reason to pick this part over a plain buck controller.
Where this code fits
Portable medical carts, handheld instruments with a dock, 24 V industrial battery backup, and any product where the host wants to read charge state over a bus instead of guessing from a comparator. Nine cells is outside the battery ceiling, so a 36 V pack needs a different topology.
Sourcing notes and next step
Confirm the temperature letter against the enclosure and confirm the chemistry option against the pack, because the pin straps set the algorithm and a wrong strap on a LiFePO4 pack is a field failure rather than a setting. Our ADI second source page lists what we can quote against a code, the lead time page covers schedule, and the analog and mixed signal category holds the rest of the charger family.
Request Quote — In Stock, 100% New & Original, Full Warranty