Contact Us

LT3798IMSE#TRPBF

Brand: Analog Devices
Analog Devices LT3798IMSE#TRPBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LT3798IMSE#TRPBF — Analog & Mixed-Signal ICs | Superb Automation

LT3798IMSE#TRPBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LT3798IMSE#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LT3798IMSE#TRPBF: an isolated PFC flyback with no optocoupler

LT3798IMSE#TRPBF is the industrial release of the LT3798 in the 16-lead MSOP with an exposed pad, on tape and reel. It is a single stage isolated flyback controller that carries active power factor correction and reads the output voltage without an optocoupler, which removes the oldest drift path in an offline supply. The front page states the size of the job plainly: 5 W to 100 W and above, with the input and output set by the external parts rather than by the controller.

Published values

ParameterValue
Input voltage at the VIN pin10 V to 38 V
Output rangeset by the transformer, the switch and the output diode
Power factorabove 0.97 in the published reference application
Efficiencyabove 86 percent at output power up to 100 W
Output regulationconstant voltage and constant current, plus or minus 5 percent typical
Reference output2.0 V, 1.97 V to 2.03 V at no load
Feedback voltage1.25 V, 1.22 V to 1.28 V over temperature
Current sense limit96 mV minimum, 102 mV typical, 107 mV maximum
INTVCC regulator10 V, 9.8 V to 10.4 V, 25 mA class
Enable threshold1.25 V on EN/UVLO, 1.21 V to 1.29 V
Oscillator150 kHz maximum, 4 kHz minimum, 20 kHz backup during a fault
Conduction modecritical, also called boundary, with discontinuous operation at light load
No load input powerbelow 0.5 W, Energy Star compliant
Thermal resistance50 C/W junction to ambient, 10 C/W junction to the pad
Package16-lead MSOP with exposed pad, tape and reel

What carries the feedback when there is no optocoupler

The output voltage is sampled from a third winding on the transformer during the off time, held on a sample and hold, and compared with the 1.25 V reference. That removes the optocoupler and its current transfer ratio drift, and it moves the accuracy question to the transformer: the sampled winding has to track the secondary within the regulation budget, which means coupling and leakage are part of the specification rather than a detail.

The controller relies on boundary mode and discontinuous mode to know when the secondary current has reached zero, so a transformer specified for continuous conduction is not interchangeable. This is the single most common mismatch when a second source is proposed for a board that already works.

The sense resistor sets the current, and 102 mV sets the resistor

The current sense threshold is 102 mV typical, with a 96 mV to 107 mV spread. At a 1 A peak primary current the sense resistor is 0.102 ohm; at 2 A peak it is 0.051 ohm. The tolerance on the threshold is 5 percent of the limit before the resistor tolerance is added, which is where the plus or minus 5 percent constant current figure comes from.

That also sets the loss in the sense resistor: 102 mV across 0.051 ohm at 2 A peak is 0.2 W in a part that has to survive the primary pulse current. A 1206 body rather than an 0805 is the usual answer in a 24 W adapter, and the kelvin connection back to the SENSE pin matters more than the resistor value once the trace resistance is a milliohm.

Universal input, and the 150 kHz ceiling

265 V AC rectifies to 375 V peak, and 90 V AC to 127 V peak, so the transformer primary has to hold the difference while the controller modulates the input current to hold the power factor above 0.97. The oscillator tops out at 150 kHz, which is a 6.67 us period, and that period sets the primary inductance for a given peak current.

At the other end, the standby requirement is below 0.5 W, which at a 24 V output is 21 mA of output current. A supply that meets 0.5 W at 230 V AC usually misses it at 265 V AC because the bleed network and the snubber scale with the square of the line voltage, so the no load measurement has to be taken at the top of the range, not at nominal.

Where a customer needs a second position on this part, component lead time solutions is the starting point, one stop BOM sourcing sets out the checks a substitution has to pass, and medical device components is the short lead time route we quote against.

Two questions buyers ask

Can a flyback transformer from another controller be used? Only if it was specified for boundary or discontinuous conduction and if the sampled winding tracks the secondary within the regulation budget. A continuous mode transformer changes the current waveform the controller depends on and the sampled voltage no longer represents the output.

Does the part need an optocoupler for safety spacing? No. Isolation comes from the transformer, and the feedback path is magnetic through the third winding. Creepage and clearance are then a transformer and board question, not a controller question.