The ADN4651BRWZ-RL7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

ADN4651BRWZ-RL7: 600 Mbps across a 5 kV barrier, where the bit period is 1.67 ns and the propagation delay is 4.5 ns

The ADN4651BRWZ-RL7 is an Analog Devices isolated LVDS buffer with two transmit and receive channels, rated to 600 Mbps with 5 kV rms of isolation in the 20-lead SOIC version, which is the body this order code specifies. It complies with TIA/EIA-644-A, runs from a 2.5 V or 3.3 V supply with an internal regulator that derives 2.5 V from 3.3 V, and specifies 4.5 ns maximum propagation delay, 151 ps maximum peak to peak total jitter at 600 Mbps, 100 ps maximum pulse skew and 600 ps maximum part to part skew. The barrier carries UL 1577 recognition at 5000 V rms for one minute, a 600 V peak maximum working voltage under VDE 0884-17, and it is qualified to IEC 62368-1, 60601-1 and 61010-1 with 7.8 mm of creepage in this package. Supply ripple rejection is minus 75 dBc, common mode transient immunity exceeds 25 kV per microsecond, and the part is specified from -40 C to +125 C. It is on the analog and mixed-signal IC line card.

At 600 Mbps the bit is 1.67 ns and the delay is 2.7 bits

One bit period at 600 Mbps is 1,666.7 ps, which makes the 4.5 ns maximum propagation delay 2.7 bit periods and the 151 ps of total jitter 9.1 percent of a bit. Pulse skew of 100 ps is 6 percent of a bit, and part to part skew of 600 ps is 36 percent of a bit, which is the number that decides whether two lanes can be sampled by the same clock. A 600 Mbps data rate is 300 MHz of fundamental, so the isolation barrier is passing a 300 MHz signal through a transformer the size of a bond pad, and the ripple rejection figure says the barrier is not perfectly transparent to the supply. The practical consequence is that the power supply on each side has to be quiet at the data rate, not just at dc.

ParameterVendor figureDerived figure
Data rate600 Mbps per channel1,666.7 ps per bit, a 300 MHz fundamental
Propagation delay4.5 ns maximum2.7 bit periods of latency
Total jitter151 ps peak to peak9.1 percent of the bit period
Pulse skew100 ps maximum6 percent of a bit, a duty cycle error of 6 percent
Part to part skew600 ps maximum36 percent of a bit, the limit on lane to lane capture
Isolation, this package5000 V rms for one minute7,071 V peak, a test and not a continuous rating
Working voltage600 V peak under VDE 0884-1711.8 times below the test voltage
Creepage7.8 mm in the 20-lead SOICthe spacing that supports the 5 kV claim
Transient immunityabove 25 kV per microseconda 1 kV step in 40 microseconds does not corrupt the output
Supply2.5 V or 3.3 V with an internal regulatora 3.3 V backplane with a 2.5 V barrier inside

The fail-safe condition is the one that keeps a link from lying

An LVDS receiver with no input drive sits at an undefined level, and an undefined level on a clock line becomes a burst of edges at the receiving end. This part drives its output high when the input is open, shorted or terminated but not driven, which turns a broken cable into a known idle state rather than a random one. That behaviour is stated for the ADN4651 and ADN4652 and it is the reason to prefer this part over a plain LVDS receiver behind a barrier. The same barrier has to survive 25 kV per microsecond of common mode transient, which is the figure that matters when the two sides are referenced to different grounds that move with a motor or a mains transient.

5 kV rms and 600 V peak are not the same claim

The 5 kV rms is a one minute withstand test under UL 1577 and equals 7,071 V peak. The number that describes service life is the 600 V peak maximum working voltage under VDE 0884-17, and the ratio between them is 11.8. A board that passes a routine 5 kV test therefore cannot be described as having a 5 kV working barrier, and a 600 V bus sits exactly at the certificate limit with no margin. The SSOP version of the same part carries 3.75 kV rms and a smaller creepage, so the package is part of the safety argument and not just a footprint decision.

Selection notes

  • The channel arrangement differs between the three family members, so the transmit and receive count has to match the link direction before the order code is fixed.
  • The internal regulator means a single 3.3 V rail on each side can feed the part, with the 2.5 V derived locally.
  • Radiated emissions meet EN55022 Class B with a 600 Mbps pseudo random pattern, which is the test that a discrete barrier and a separate LVDS driver usually fail.
  • At 600 Mbps the trace from the connector to the part is part of the signal path, so its impedance and its length relative to 1.67 ns have to be treated as a transmission line.

Questions buyers ask

Does 5 kV rms mean the part can be used on a 5 kV bus? No. The 5000 V rms is a one minute withstand test; the continuous working voltage is 600 V peak. A 600 V bus is at the limit, not comfortably inside it.

Can two lanes be captured with one clock? Only if the 600 ps part to part skew is inside the capture window, which is 36 percent of a 600 Mbps bit. Above that rate the lanes need their own capture or a source synchronous clock.

Isolated interface alternatives are compared in pin to pin cross reference, and supply continuity for a qualified build is handled under BOM shortage recovery.