Contact Us

AD623BRZ-R7

Brand: Analog Devices
Analog Devices AD623BRZ-R7 is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

AD623BRZ-R7 — Analog & Mixed-Signal ICs | Superb Automation

AD623BRZ-R7

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The AD623BRZ-R7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

AD623BRZ-R7: A Rail to Rail Instrumentation Amp That Loses Bandwidth as Gain Rises

The AD623BRZ-R7 is a single or dual supply instrumentation amplifier with a rail to rail output, a gain range of 1 to 1000 set by one external resistor, 0.35 percent gain error above unity, 35 nV per root hertz of input noise, 550 uA maximum quiescent current and an input range that extends 150 mV below ground on a single supply, in an 8-lead SO package. It is the low cost member of the instrumentation amplifier family, and the two numbers that decide whether it suits an application are the bandwidth at gain and the offset against the signal.

Bandwidth collapses with gain

The 800 kHz figure belongs to unity gain. With a fixed gain bandwidth of about 800 kHz, a gain of 100 leaves 8 kHz and a gain of 1000 leaves 800 Hz. A thermocouple or bridge front end that needs 100 Hz of signal bandwidth is comfortable at a gain of 100, and a vibration sensor that needs 10 kHz is not. Reading the 800 kHz as the bandwidth of the amplifier at any gain is the most common error made with this part.

Gain range1 to 1000, one external resistor
Supply range2.7 V to 12 V, single or dual
Gain error0.10 percent at unity, 0.35 percent above unity
Input noise35 nV per root hertz at 1 kHz, 11.1 uV RMS over 100 kHz
Bandwidth800 kHz at unity, about 8 kHz at a gain of 100
Settling20 us to 0.01 percent at a gain of 10
Input common mode150 mV below ground on a single supply
Quiescent current550 uA maximum, 2.75 mW at 5 V
OutputRail to rail swing

Noise and power in a bridge front end

Thirty five nanovolts over 100 kHz is 11.1 uV RMS referred to the input, which becomes 1.11 mV at the output at a gain of 100. Against a 10 mV bridge signal that is a 1 percent noise floor, and the amplifier is not the only contributor: a 350 ohm bridge on a 5 V excitation draws 14 mA, so the bridge, not the amplifier, is the power budget. The 550 uA maximum quiescent current matters in a loop powered or battery instrument where the whole front end has to fit inside 4 mA.

A 30 kohm bridge on the same 5 V draws 167 uA, which is about a third of what the amplifier itself can draw. That ratio is worth checking before choosing a high value bridge to save power: below a few tens of kilo ohms the amplifier is the larger load, and the power saving from the bridge is smaller than expected.

Where it fits

Low power medical instrumentation, transducer interfaces, thermocouple amplifiers, industrial process control, difference amplifiers and low power data acquisition. The 150 mV below ground input range is what allows a single supply bridge with a grounded arm to be measured without a negative rail, and the rail to rail output makes the full converter range usable at a gain of 1.

Two questions buyers ask

Does the B grade matter?
Grades in this family differ in gain error, offset and drift rather than in function. A DC bridge measurement at a gain of 100 spends its error budget on offset and drift, and that is where the grade shows. For an AC measurement with a high pass filter the grade matters much less.

What happens if the gain resistor is left out?
The amplifier is configured for unity gain, so the stage still works and simply does not amplify. That is useful during bring up, and it is also why a missing resistor on a production board produces a working channel with the wrong scale rather than no signal at all.

Supply and matching

The BRZ-R7 code is the 8-lead SO, 7 inch tape and reel, lead free, and the part follows the standard instrumentation amplifier pinout so the gain resistor sits in the same place across the family. The family is on the analog mixed signal ICs page, amplifier alternatives are compared in the amplifier cross reference, and a sensor front end for a medical instrument is covered under medical device components.

Request Quote — In Stock, 100% New & Original, Full Warranty