SPB339360P3
Product Specifications
SPB339360P3
Superb Automation — Amplifiers & Comparators
Product Overview
The SPB339360P3 from Superb Automation is a precision amplifier / comparator delivering high gain, wide bandwidth, and low distortion for signal conditioning. Superb Automation supplies this part with incoming inspection, test records and lot traceability.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High gain-bandwidth product for wideband signal amplification
- Low input offset voltage and drift for precision DC applications
- EMI-hardened design for robust operation in noisy environments
- Rail-to-rail input/output for maximum dynamic range
- Low quiescent current for power-sensitive designs
- Unity-gain stable with capacitive load drive capability
Key Specifications
| Channels | — |
| GBWP | MHz |
| Slew Rate | V/µs |
| Vos | µV |
| Iq per Channel | µA |
| Input Type | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
Applications
SPB339360P3: two published rows for one part number, and which one travels with the order
The SPB339360P3 appears twice in the vendor documentation, and the two entries disagree on almost every headline figure. The family table gives 0.1 to 6 GHz, 16 dB of gain, 4.5 dB noise figure, 27 dBm of output and a 12 V rail at 240 mA. The device page for the same part gives 0.5 to 6 GHz, 12 dB of gain, 18 dBm at the 1 dB compression point, 38 dBm of output intercept and a 5 V rail at 80 mA. A buyer who compares this part number against a competitor using the first row and then buys against the second will be wrong by 9 dB of output power. This page sets out both rows and the questions that settle it.
What each document actually states
| Parameter | Family table | Device page |
|---|---|---|
| Frequency range | 0.1 to 6 GHz | 0.5 to 6 GHz |
| Small signal gain | 16 dB | 12 dB |
| Output at compression | 27 dBm, quoted at P-3dB | 18 dBm at P-1dB |
| Output intercept | not stated | 38 dBm at 3 GHz |
| Supply | 12 V at 240 mA | 5 V at 80 mA |
| Package | QFN 3 x 3 | QFN 3 x 3 x 1.1 mm |
| DC input implied | 2.88 W | 0.40 W |
| Efficiency at that point | 17.4 percent | 15.8 percent |
Why the gap is 9 dB and not a rounding difference
27 dBm is 0.501 W and 18 dBm is 0.063 W. The ratio is 7.94, or 9.00 dB exactly, and the DC input ratio between the two rows is 7.20. A 9 dB disagreement between two documents from the same vendor is not a measurement tolerance. The two rows also quote different compression criteria, one at 3 dB of gain compression and one at 1 dB, and different rails, so they may describe two bias points of the same die rather than one operating condition. What matters for a purchase order is that only one of them can be screened on the line.
The drive level that follows from each row
At 16 dB of gain and 27 dBm, the part needs 11 dBm at its input before it compresses. At 12 dB of gain and 18 dBm, it needs 6 dBm. That is the practical difference between the two rows: the first version demands a driver stage in front of it, the second can be fed from a synthesizer module or a DAC output that already delivers a few dBm. If your chain has 0 dBm available at this point, the 16 dB row is unusable without another gain block, and adding that block changes the noise figure of everything behind it.
Questions to put to the vendor before ordering
Which row matches the datasheet revision we will receive? Ask for the revision letter and for the test condition behind the compression figure. If the answer is the 5 V row, order against 18 dBm and plan the supply for 80 mA, not 240 mA.
Is the 12 V row a different bias of the same die? If it is, the part can probably be screened at either point, and a purchaser who needs 27 dBm should say so on the order line rather than expecting the default screening to deliver it. If it is a different die, the two rows are not interchangeable and the part number needs a suffix.
SUPERB supplies the SPB339360P3 against the row you specify, with the vendor table confirmed on the order. For an existing 0.5 to 6 GHz stage being re sourced, the amplifier cross reference hub lists the parameters that have to be matched before a swap is safe, and obsolete RF part replacement covers the case where the original device is no longer available. Stock and price break for this part sit in the amplifiers and comparators index.
SPB339360P3: the order travels with one of the two rows, and the test that decides which
Two documents describe this part number and they disagree by 9 dB of output and 2.5 W of DC. A purchase order that names only the part number therefore does not say what will be screened on the line, and the difference between the two readings is large enough to change the stage in front of the amplifier and the regulator behind it. This is a specification control problem more than an RF problem, and it is settled with two measurements rather than an argument.
Put the row on the purchase order, not just the part number
The family table row is 16 dB of gain, 27 dBm at 3 dB of compression, a 12 V rail at 240 mA and 0.1 to 6 GHz. The device page row is 12 dB of gain, 18 dBm at 1 dB of compression, an intercept of 38 dBm, a 5 V rail at 80 mA and 0.5 to 6 GHz. Note that the two output figures are not even quoted on the same criterion: a part read at 3 dB of compression reports roughly 1.5 to 2 dB more than the same part read at 1 dB, so 27 dBm at P-3dB corresponds to about 25 dBm at P-1dB. Against the device page's 18 dBm that is still a 7 dB gap, and no compression criterion explains 7 dB. The rails and the currents differ by a factor of 7.2 in DC, which points at two bias points of the same die rather than two different parts.
| What the order should state | Why it matters |
|---|---|
| Compression criterion, 1 dB or 3 dB | the two documents differ by 9 dB on this alone once the criterion is mismatched |
| Bias point, rail and current | 12 V at 240 mA and 5 V at 80 mA are 2.88 W and 0.40 W of DC |
| Band edges tested, 0.1 and 6 GHz or 0.5 and 6 GHz | the lower edge differs between the two rows |
| Gain at the top of the band | 12 and 16 dB are quoted as flat figures with no test frequency |
| Intercept and its test level | 38 dBm is stated without a tone spacing |
Two measurements settle it on the bench
Sweep input power at 3 GHz and plot output against input until the trace bends. The 1 dB point read off that curve is directly comparable with the device page, and the current drawn at that point tells you which bias row the lot was built to. Both numbers take an afternoon and they remove the ambiguity from every later conversation. The second measurement is the band edge: run the sweep at 0.1, 0.5 and 6 GHz. A part that holds 12 dB at 3 GHz and drops 3 dB at 6 GHz is behaving normally for a 6 GHz cell, but a buyer who planned on the family row will read that drop as a failure. If the answer matters before the parts arrive, ask for a sweep at the two edges with the bias point written on the plot, which is the same request we make of the line when a part in this class is quoted from two sources, as described on how to verify a drop in replacement.
What the DC difference does downstream
At 12 V and 240 mA the regulator, the decoupling and the heat path all belong to a 3 W class of circuit. At 5 V and 80 mA they belong to a 0.4 W class. If the board is built for the second row and the lot arrives built to the first, the 5 V rail will not bias it at all, and if the board is built for the first row and the lot follows the second, the extra headroom simply goes unused while the regulator stays oversized. Neither outcome is dangerous, both are avoidable, and the cost of avoiding them is one line on the order. The 12 V row also needs a bias sequence in most systems because the drain is fed from a rail that comes up after the logic supply, and the 5 V row does not, because the same rail that feeds the logic feeds the drain.
Two questions buyers ask
Is the 16 dB row simply the 12 dB row at a higher rail? That is the most economical explanation and it fits the 7.2 to 1 DC ratio, the rise in output and the wider band claim. It also fits the fact that both rows are printed for the same package. It is not stated by the vendor, so treat it as a hypothesis to confirm with a sweep at both rails rather than as a fact to put in a budget.
Which row should a new build plan on? The lower one, 12 dB and 18 dBm, because a part that exceeds it costs nothing extra and a part that misses the higher row costs a rebuild of the stage in front. Parts in this family and their published rows are collected on our amplifier cross reference page, and the supply position on the wider family is on RF component sourcing.
Request Quote — In Stock, 100% New & Original, Full Warranty