Product Overview

The TJA1055T/3/CM from NXP Semiconductors is a microcontroller / embedded processor engineered for real-time control, signal processing, and connectivity. NXP Semiconductors provides secure connectivity solutions, embedded processors, and automotive-grade MCUs for edge computing.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • ARM Cortex / RISC-V / proprietary core with high-performance real-time processing
  • Integrated flash memory and SRAM for efficient code execution
  • Rich peripheral set: UART, SPI, I2C, ADC, timers, PWM
  • Low-power modes for battery-operated and energy-sensitive applications
  • Hardware security features: secure boot, crypto accelerator, TRNG
  • Extensive development ecosystem with IDE, HAL, and RTOS support

Key Specifications

Core—
Max FrequencyMHz
FlashKB
SRAMKB
GPIO—
ADCbits
Interfaces—
Supply VoltageV
Operating Temp°C
Package—

Applications

Industrial Motor Control IoT Edge Nodes Consumer Electronics Automotive Body Control Smart Home & Appliances Medical Portable Devices

Request Quote — In Stock, 100% New & Original, Full Warranty

TJA1055T/3/CM: SO14 fault tolerant CAN transceiver for 3 V logic

TJA1055T/3/CM is the fault tolerant CAN transceiver in the SO14 body with 3 V logic levels in the TJA1055 fault tolerant CAN transceiver line, described by Rev 5 of 6 December 2013. It is a fault tolerant low speed CAN transceiver for networks up to 125 kBd, and the /3 code is the member built for 3 V logic. The point of the part is that a broken bus wire does not stop the network: the transceiver falls back to single wire operation and keeps the nodes talking at reduced performance.

Order code and package

Order codeTJA1055T/3/CM
Variant function on pin 5STB, EN and WAKE inputs with INH and ERR outputs, and 3 V compatible logic on this code
PackageSO14, 3.9 mm body width, 14 pins
Protocolfault tolerant low speed CAN per ISO 11898-3, with differential and single wire operation
Maximum data rateup to 125 kBd
Supply voltage on VCC4.75 to 5.25 V
Logic supply on VIOnot present as a separate pin; the /3 code accepts 3 V logic levels
Temperature rangeminus 40 to plus 150 C virtual junction
QualificationAEC-Q100
DatasheetRev 5 of 6 December 2013

Electrical parameters that decide the application

Bus fault voltageminus 58 to plus 58 V on CANH and CANL with the supply at 0 V and no time limit
Supply currentSleep mode current is reduced to a minimum and wake-up is signalled on RXD and ERR with VCC off
Electrostatic discharge6 kV IEC 61000-4-2 on the off-board pins
Thermal resistance120 K/W junction to ambient in the SO14 body, 40 K/W junction to solder point
Wake and diagnostic pinsSTB, EN and WAKE inputs, INH output, ERR output indicating the failure mode, and automatic single wire fallback
Bus pinsCANH and CANL, differential, with the recessive level set by the on chip driver or by a SPLIT output where the code carries one
Logic levels3 V logic levels on TXD, RXD, STB, EN and ERR, with RXD and ERR as open drain outputs
Behaviour with the supply offthe transceiver disengages from the bus so an unpowered node does not load the network
ProtectionTXD dominant time-out, undervoltage detection and thermal shutdown are named in every document in this family
Ordering stringthe suffix after the slash carries the body, the packing and the variant, so it has to be quoted in full on a purchase order

Points to check before this part goes on a BOM

The bus window is minus 58 to plus 58 V with the supply at 0 V and no time limit, which is what makes the part usable on a two wire harness that can be shorted to battery or to ground anywhere along its length.

Single wire fallback is the function that separates this from every high speed part in this batch. A break in CANH, CANL or the ground reference moves the network to single wire mode instead of taking it down, and the ERR output tells the controller which failure it detected.

The node termination is switched, with RTL and RTH connected only while the node is powered. That is the reason an unpowered node does not load a fault tolerant bus, and it is also why the termination cannot be checked with a meter on a board that has no supply.

The dominant output is specified as VCC minus 1.4 V on CANH and 1.5 V on CANL at 40 mA, which is a voltage drop specification rather than a drive strength. A network with more than a few dozen nodes starts to show that as a common mode shift at the far end.

The /3 code carries a current source to ground where the plain code has a pull-up to VCC, and its RXD and ERR are open drain. Those two changes are what allow 3 V logic, and they also mean the two codes are not interchangeable on a board that already has pull-ups fitted.

The document quotes 6 kV IEC 61000-4-2 on the off-board pins and 8 kV human body model on CANH and CANL, with 4 kV on the other pins. Those are the highest per pin numbers in this batch after the 8 kV high speed parts, which reflects a bus that leaves the board on a long harness.

Thermal resistance is 120 K/W in the SO14 body with 40 K/W to the solder point, so the part is limited by the board copper rather than by the package. A driver that dominates the bus continuously at 40 mA on both wires is dissipating more than the arithmetic of a 125 kBd network suggests.

Where this order code fits

It is the part for comfort and body networks where a harness fault must not take the bus down, and it is common in 3.3 V controllers running LIN and CAN side by side. Boards weighing one CAN transceiver against another start from our CAN Bus Transceiver Selection page, and boards replacing a part that has gone end of life start from the Incoming Inspection Plan page.

Questions buyers ask

What happens to the network if one bus wire breaks? The transceiver falls back to single wire operation and the ERR output reports the failure, so the nodes keep communicating at reduced performance instead of dropping off the bus.

Is TJA1055T/3 the same as TJA1055T? No. The /3 code has 3 V logic levels, a current source to ground where the plain code has a pull-up to VCC, and open drain RXD and ERR outputs.

Does it work with a 5 V controller? The /3 code is built for 3 V logic. A 5 V controller belongs on the plain TJA1055T code, which carries 5 V thresholds and push-pull outputs.

SUPERB holds and sources NXP interface lines including this order code for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated. When a line is changing, the Component Obsolescence Management page sets out the checks that keep a substitute from failing on the bench.