TJA1043T/1
Product Specifications
TJA1043T/1
NXP Semiconductors — MCU & Embedded Processors
Product Overview
The TJA1043T/1 from NXP Semiconductors is a microcontroller / embedded processor engineered for real-time control, signal processing, and connectivity. NXP Semiconductors provides secure connectivity solutions, embedded processors, and automotive-grade MCUs for edge computing.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- ARM Cortex / RISC-V / proprietary core with high-performance real-time processing
- Integrated flash memory and SRAM for efficient code execution
- Rich peripheral set: UART, SPI, I2C, ADC, timers, PWM
- Low-power modes for battery-operated and energy-sensitive applications
- Hardware security features: secure boot, crypto accelerator, TRNG
- Extensive development ecosystem with IDE, HAL, and RTOS support
Key Specifications
| Core | — |
| Max Frequency | MHz |
| Flash | KB |
| SRAM | KB |
| GPIO | — |
| ADC | bits |
| Interfaces | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TJA1043T/1: SO14 CAN FD transceiver with INH, ERR and listen-only
TJA1043T/1 is the SO14 member of the line that controls the node supply as well as the bus in the TJA1043 high speed CAN transceiver line with full node power control, described by Rev 6 of 10 November 2017. It is the member of this family that runs the node rather than only the bus. An INH output switches the regulator that feeds the microcontroller, an ERR output reports what went wrong, and a listen-only mode lets a node watch the bus while it is being diagnosed. The cost is five extra pins and a larger body.
Order code and package
| Order code | TJA1043T/1 |
| Variant function on pin 5 | STB, EN and WAKE inputs with INH and ERR outputs; pin 5 and pin 11 are the enable and error pins rather than a variant selector |
| Package | SO14, 3.9 mm body width, 14 pins |
| Protocol | ISO 11898-2:2016 and SAE J2284-1 to SAE J2284-5 |
| Maximum data rate | 5 Mbit/s in the CAN FD fast phase |
| Supply voltage on VCC | 4.5 to 5.5 V |
| Logic supply on VIO | 2.8 to 5.5 V on every code, since the part always carries a VIO pin |
| Temperature range | minus 40 to plus 150 C virtual junction |
| Qualification | AEC-Q100 |
| Datasheet | Rev 6 of 10 November 2017 |
Electrical parameters that decide the application
| Bus fault voltage | minus 58 to plus 58 V on CANH and CANL |
| Supply current | Standby and sleep currents are the lowest in this family, and listen-only mode draws the normal recessive current without driving the bus |
| Electrostatic discharge | plus or minus 8 kV IEC 61000-4-2 at CANH and CANL |
| Thermal resistance | 68 K/W junction to ambient in the SO14 body |
| Wake and diagnostic pins | STB, EN and WAKE inputs, INH output for the node regulator, ERR output for diagnostics and a listen-only mode |
| Bus pins | CANH and CANL, differential, with the recessive level set by the on chip driver or by a SPLIT output where the code carries one |
| Logic levels | TXD, RXD, STB and EN referenced to VIO, which accepts 3 V to 5 V |
| Behaviour with the supply off | the transceiver disengages from the bus so an unpowered node does not load the network |
| Protection | TXD dominant time-out, undervoltage detection and thermal shutdown are named in every document in this family |
| Ordering string | the suffix after the slash carries the body, the packing and the variant, so it has to be quoted in full on a purchase order |
Points to check before this part goes on a BOM
INH is the output that powers the rest of the node, so the transceiver decides when the microcontroller gets a supply. That is what allows a control unit to sit at a few microamps with its regulator off and still wake on a bus pattern, and it is the difference between this part and the TJA1042.
ERR reports the failure mode: a short on CANH or CANL, a short to battery, a bus wiring fault. The signal is latched until it is read, so a controller that never reads it loses the diagnostic and a controller that polls it can tell a wiring fault from a silent bus.
Listen-only mode disables the transmitter while the receiver keeps working, which is what a diagnostic tester needs on a live network. The mode is entered through the EN and STB pins, not by removing VCC, so the wake logic stays armed.
VIO is 3 V to 5 V on every code in this line, so the digital interface follows the controller without an external translator, and the 5 V side of the bus stays on VCC.
The SO14 body is 68 K/W. A 70 mA dominant bus at 5 V is 350 mW, which is a 24 C rise and lands at 109 C in an 85 C ambient, so the package has room for the extra current of driving INH into a regulator enable and a pull-up.
Bus pins stand minus 58 to plus 58 V and carry plus or minus 8 kV IEC 61000-4-2. The battery connection detection in the failure logic uses that same window, so a board that clamps the bus below 58 V with a suppressor can mask the very fault the part is meant to report.
Five extra pins and a bigger body are the whole cost of this part against the TJA1042. On a board that already has a regulator with an enable pin and a spare microcontroller input, that cost is close to zero, which is why the part is common in gateways and body controllers.
Where this order code fits
It is the part for gateways, body controllers and any node that has to switch its own supply off and wake on traffic, and it is the usual step up from a TJA1042 when the node grows a regulator enable. Boards weighing one CAN transceiver against another start from our CAN Bus Transceiver Selection page, and boards replacing a part that has gone end of life start from the Component Obsolescence Management page.
Questions buyers ask
What does the INH pin do? It is a high side output that switches the node regulator, so the transceiver can power the microcontroller up on a bus wake and remove its supply in sleep.
Can the ERR pin distinguish a short from a silent bus? Yes. ERR reports bus line short circuit and battery connection conditions, so a wiring fault reads differently from a bus that is simply idle.
Is the digital interface 3.3 V compatible? Yes. VIO accepts 3 V to 5 V on every code in this line, and TXD, RXD, STB and EN are referenced to it.
SUPERB holds and sources NXP interface lines including this order code for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated. When a line is changing, the Strategic Sourcing page sets out the checks that keep a substitute from failing on the bench.