UCC2895DWTR
Product Specifications
UCC2895DWTR
Texas Instruments — Power Management & Signal Chain
Product Overview
The UCC2895DWTR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
UCC2895DWTR: phase shifted full bridge controller with programmable output delay in a 20 pin SOIC
UCC2895DWTR is a phase shifted full bridge PWM controller in the 20 pin DW body that runs from an 11 V start threshold, oscillates at 500 kHz with 82 kohm and 220 pF of timing components, and sets its output dead time either by resistor or adaptively from the current sense signal in a SOIC body of 20 pins. The UCC2895 is the industrial temperature member of the UCC3895 family, with the commercial UCC3895 alongside it and the military UCC1895 above it. The controller drives four outputs in two legs with a programmable phase shift between them, which is the arrangement used for zero voltage switching in an isolated full bridge. Timing comes from RT and CT, output delay from the DELAB and DELCD resistors or from the ADS pin, and the error amplifier, soft start and current sense chain are all on chip.
Order code and package
| Order code | UCC2895DWTR |
| Function | phase shifted full bridge PWM controller |
| Start threshold | 10.2 V to 11.8 V, 11 V typical |
| Operating threshold after start | 8.2 V to 9.8 V, 9 V typical |
| Supply clamp | 17.5 V typical at 10 mA |
| Reference output | 5 V, 4.94 V to 5.06 V at 25 C |
| Oscillator frequency with RT 82 kohm and CT 220 pF | 473 kHz to 527 kHz, 500 kHz typical |
| Package | 20 pin SOIC, DW body |
| Temperature range | minus 40 C to 85 C |
| Document | SLUS157Q, December 1999, revised October 2019 |
Electrical parameters that decide the application
| Oscillator variation over line and temperature | 2.5 percent typical, 5 percent maximum |
| Timing resistor voltage | 2.9 V to 3.1 V, 3 V typical |
| Timing capacitor peak voltage | 2.25 V to 2.55 V, 2.35 V typical |
| Timing capacitor valley voltage | 0 V to 0.4 V, 0.2 V typical |
| Sync input threshold | 2.05 V to 2.4 V, 2.1 V typical |
| Sync output pulse width | 85 ns to 135 ns |
| Peak current threshold | 1.9 V to 2.1 V, 2 V typical |
| Overcurrent threshold | 2.4 V to 2.6 V, 2.5 V typical |
| Current sense to output delay | 75 ns to 110 ns typical |
| Output delay with ADS at 0 V | 450 ns to 620 ns, 560 ns typical |
| Soft start source current | minus 30 uA to minus 40 uA, minus 35 uA typical |
| Soft start sink current | 325 uA to 375 uA, 350 uA typical |
| Soft start comparator threshold | 0.44 V to 0.56 V, 0.5 V typical |
| Start-up current at 8 V | 150 uA to 250 uA |
| Operating supply current | 5 mA to 6 mA |
| No load comparator hysteresis | 35 mV to 165 mV, 100 mV typical |
| Thermal resistance, junction to ambient in the DW body | 66.4 C per W |
Points to check before this part goes on a BOM
The start threshold window is the first thing to check against a 12 V bias rail. The part starts between 10.2 V and 11.8 V and runs down to 9 V, so a 12 V rail at minus 5 percent is 11.4 V, which is below the 11.8 V worst case start threshold. A converter fed from a 12 V housekeeping rail therefore may not start on a cold board with a low line, and the fix is either to raise the bias rail or to accept a lower start threshold part. This is arithmetic that a bench test at nominal voltage will never show.
Output delay is programmable two ways and the two are not the same control. With the ADS pin grounded the delay is fixed by the DELAB and DELCD resistors, specified at 560 ns typical between the edges of one leg. With ADS connected to the current sense signal the delay shrinks as the load falls, which keeps zero voltage switching at light load without holding a long dead time that costs circulating current at full load. At 500 kHz the period is 2 us, so 560 ns is 28 percent of a period and twice that is a real limit on the achievable duty cycle.
Current sense protection has two levels on one pin: a 2 V peak threshold that terminates the cycle and a 2.5 V overcurrent threshold that starts a second, slower response. The propagation delay from the sense pin to the output is 75 ns to 110 ns, which at a 2 us period is up to 5.5 percent of a cycle. During a short circuit the peak current therefore overshoots by the amount the current can rise in that delay, which is why the shunt and the filter in front of the CS pin are part of the protection rating rather than an afterthought.
The reference is 5 V at plus or minus 1.2 percent, and the delay resistors are driven from it, so the delay inherits that tolerance on top of the resistor tolerance. Using the reference for the timing chain is convenient and it means a reference that drifts with temperature moves the dead time with it, which matters in a converter that has to hold zero voltage switching from a cold start to a hot soak.
Soft start charges at 35 uA and discharges at 350 uA, a ratio of ten to one. The slow charge is what limits inrush into the output capacitance, and the fast discharge is what makes a fault turn the converter off quickly. The threshold is 0.5 V, so the capacitor value and the 35 uA set the ramp time directly, and a board that changes the capacitor to shorten start up also changes the fault response.
The oscillator is set by RT and CT and its total variation over line and temperature is 5 percent maximum. Since the timing capacitor swings between 0.2 V and 2.35 V, the ramp amplitude is fixed by the part and the frequency is set by the external components. That is a stable arrangement, and it also means a 5 percent change in frequency moves the dead time fraction and the transformer flux swing together, which is why the transformer is usually specified at the low frequency end of the window.
The temperature grade is the difference between the three members of the family and it is not cosmetic. This order code is specified from minus 40 C to 85 C, the UCC3895 is 0 C to 70 C and the UCC1895 reaches 125 C. An industrial product that runs its controller board at 95 C inside an enclosure is outside this part even though the die is the same, and the DW body at 66.4 C per W means a watt of controller loss is already a 66 C rise before the ambient term.
Where this order code fits
This order code belongs in isolated DC to DC converters from a few hundred watts to a few kilowatts, telecom rectifiers, battery chargers, welding supplies and motor drives that need a full bridge with zero voltage switching. It is chosen when the input is a 48 V or 400 V bus, the output has to be regulated with a small filter, and the efficiency target is high enough that hard switched losses in four transistors are not acceptable. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Component Obsolescence Management page.
Questions buyers ask
Will this part start from a 12 V housekeeping rail? Only if the rail stays above 11.8 V at its lowest point. The start threshold is specified from 10.2 V to 11.8 V and a 12 V rail at minus 5 percent is 11.4 V. A part at the top of the window will not start at that voltage, so a 12 V rail needs a tolerance check rather than a nominal one, or a bias rail at 15 V, which is also comfortably below the 17.5 V clamp.
What does the ADS pin do? It makes the output delay track the current sense signal. With ADS grounded the delay is fixed at 560 ns typical and set by the two delay resistors; with ADS tied to the current sense ramp the delay shortens as the load current falls, which reduces circulating current at light load while keeping enough dead time for zero voltage switching at full load. A fixed delay is simpler and it is the right choice when the load range is narrow.
How much dead time does a full bridge need? Enough for the resonant transition to complete, which depends on the leakage inductance, the output capacitance of the four transistors and the load current. This controller lets that be set from 450 ns to 620 ns with resistors, or varied with load through the ADS pin. At 500 kHz a 560 ns delay consumes 28 percent of the period, so the maximum duty available to the transformer is reduced by twice that figure, and the turns ratio has to be chosen with the loss in mind.
Is the 5 V reference strong enough to drive the timing chain? It is a 5 V reference at 1.2 percent with the data sheet conditions quoted at 0.1 uF of load capacitance, and it is intended for exactly this kind of low current bias. What it does not tolerate is a timing chain that draws a variable current, because the reference has a finite output impedance and the delay then moves with the setting. Buffering the divider or using a separate reference for the delay network removes that coupling.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Obsolete Part Cross Reference Hub page sets out the checks that keep a substitute from failing on the bench.