UCC28910DR
Product Specifications
UCC28910DR
Texas Instruments — Power Management & Signal Chain
Product Overview
The UCC28910DR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
UCC28910DR: 700 V flyback switcher that regulates voltage and current without an optocoupler
UCC28910DR is a high voltage flyback switcher in the seven pin D body with an integrated 700 V device that regulates output voltage and output current from the auxiliary winding, with no optocoupler and no secondary side reference in a SOIC-7 body of 7 pins. The UCC28910 integrates a 700 V power device and a controller that reads the flyback waveform on the auxiliary winding and on the drain to regulate both output voltage and output current from the primary side. Voltage regulation is 5 percent and current regulation is 5 percent with compensation for line and primary inductance tolerance, and the start up current source is switched off during operation so the standby power can fall below 30 mW. Switching is limited to 115 kHz with valley switching and frequency dithering to ease conducted and radiated emissions.
Order code and package
| Order code | UCC28910DR |
| Integrated device voltage | 700 V |
| Topology | flyback, discontinuous conduction with valley switching |
| Regulation | constant voltage and constant current, primary side |
| Voltage accuracy | plus or minus 5 percent |
| Current accuracy | plus or minus 5 percent with line and inductance compensation |
| Maximum switching frequency | 115 kHz |
| Package | seven pin SOIC, D body |
Electrical parameters that decide the application
| Standby power | below 30 mW with the start up circuit off |
| Start up | high voltage current source, switched off during operation |
| Emissions | valley switching plus frequency dithering |
| Protection | thermal shutdown, low line, output overvoltage |
| Secondary sensing | none, no optocoupler required |
| Current sense | primary peak current on the IPK pin |
| Feedback | auxiliary winding waveform on the VS pin |
| Body size | 5.00 mm by 6.20 mm |
Points to check before this part goes on a BOM
Regulating the output from the primary side removes the optocoupler, and what it costs is accuracy. An optocoupler based circuit can hold 1 percent because it measures the output directly; this part measures the auxiliary winding during the interval when the secondary current is flowing, and the errors in that measurement are the leakage inductance spike, the diode forward drop and the propagation delay of the sampling. The 5 percent figure is the sum of those terms, and it is why a board that needs 1 percent on the output either post regulates or accepts a wider window in the load specification.
Thirty milliwatts of standby is the number that regulations ask for and the number this part is built around. At 230 V input, 30 mW is 130 microamps of input current, which is the entire budget for the controller, the start up circuit and the leakage of the input capacitor. The start up current source is switched off once the device is running and supplied from the auxiliary winding, because a resistive start up path alone would exceed the budget by an order of magnitude at high line.
Valley switching is what keeps the drain voltage from turning on into the peak of the ringing. In a discontinuous flyback the drain rings after the secondary current reaches zero, and turning on at the valley of that ring minimises the energy that the parasitic capacitance dumps into the device at every cycle. The saving is a few percent of efficiency and a measurable reduction in the high frequency content of the drain waveform, which is what the emissions limits are concerned with.
Frequency dithering spreads the switching energy across a band rather than concentrating it at the fundamental and its harmonics, which reduces the peak of the conducted emissions. It does not reduce the total energy, so a board that is close to the limit on the average will still be close, but a board that is failing on a narrow peak at one harmonic is often brought inside the limit without a bigger filter. The dithering is internal, so it is not a board choice, and the filter has to be sized for the dithered spectrum rather than for a single frequency.
The 115 kHz maximum switching frequency is a upper limit that sets the transformer for a given power. At 115 kHz the period is 8.7 us, and a discontinuous flyback needs the demagnetisation time plus the dead time inside that period, so the on time available for energy transfer is a fraction of it. That is what makes this part a fit for the 5 W to 15 W class rather than for a 50 W adapter, where a higher frequency and a different controller would be needed to keep the transformer small.
Seven pins in a small outline package with a 700 V device inside means the creepage between the drain and the neighbouring pins is a package property and cannot be improved on the board. The drain trace should be short and it should not run parallel to the feedback trace, because the feedback pin reads a waveform of a few volts while the drain swings hundreds. A routing that runs them side by side couples a fraction of the drain swing into the feedback, and the symptom is a regulation error that changes with the input voltage.
The current regulation without a sense resistor on the secondary uses the primary peak current and the demagnetisation time to compute the delivered charge, which is why the specification mentions compensation for primary inductance tolerance. The inductance of the transformer is a production tolerance of about 10 percent, and without compensation that tolerance would appear directly in the output current. The compensation is internal and it depends on the auxiliary winding ratio being the value the board assumes, so a transformer with a different turns ratio is a different current accuracy.
Where this order code fits
This order code belongs on wall adapters and chargers, IoT and smart plug supplies, metering bias, thermostat and smoke alarm bias, and auxiliary supplies in appliances, where a small isolated rail has to be produced from the mains without an optocoupler. It is also the part chosen where the standby consumption matters more than the load efficiency, because the start up circuit shuts off and the controller current is adjusted with the load. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the BOM Shortage Recovery page.
Questions buyers ask
Does it really work without an optocoupler? Yes. The output voltage is reconstructed from the auxiliary winding during the interval when the secondary conducts, and the output current from the primary peak current and the demagnetisation time. No secondary side reference, no optocoupler and no third winding are needed, at the cost of 5 percent accuracy instead of 1 percent.
How low is the standby power? Below 30 mW is the target the part is built for, with the start up current source switched off once the auxiliary winding takes over. At 230 V input 30 mW is 130 uA, so every leakage path in the input network counts against that budget.
What power level does it suit? The 115 kHz maximum frequency and the discontinuous operation put it in the 5 W to 15 W class. Higher power needs a higher frequency or a continuous mode controller to keep the transformer within a reasonable size.
What sets the output current accuracy? The primary peak current, the demagnetisation time and the primary inductance, with internal compensation for the inductance tolerance. The accuracy depends on the auxiliary winding ratio matching the value the compensation assumes, so a transformer substitution changes the current regulation even when the turns ratio looks close.
SUPERB holds and sources this switcher line against the exact order code, with the reel, date code and country of origin stated on the pack. When a supply has to move to a second part, the Component Lead Time Solutions page sets out the checks that separate a working substitute from one that fails on the bench.