UCC28881DR
Product Specifications
UCC28881DR
Texas Instruments — Power Management & Signal Chain
Product Overview
The UCC28881DR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
UCC28881DR: a 700 V off-line converter with an integrated 14 Ohm switch, 225 mA of output current and under 100 uA of quiescent current, in a seven pin SOIC on a 2500 piece reel
UCC28881DR is a complete non-isolated off-line switching stage in one body: the 700 V FET, the current sense, the high voltage start-up current source, the controller, the soft start and the protection, with no clock and no external compensation in a SOIC body of 7 pins. The D body is a seven pin SOIC, which is the eight pin outline with one pin removed for creepage, and the part exists because a 5 V housekeeping supply inside a mains product has to start from the rectified rail and still draw almost nothing when the product is idle.
Order code and package
| Catalogue string | UCC28881DR, where D is the seven pin SOIC and R is the 2500 piece large reel |
| Body | SOIC, D, seven pins in a 5.00 mm by 6.20 mm outline, with the drain pin placed to hold the creepage the mains voltage needs |
| Reel | 2500 pieces on a large tape and reel on the addendum dated 23 September 2026 |
| Tube | the same die ships 75 pieces in a tube as UCC28881D for a first article build |
| Finish and moisture | NIPDAU plating, moisture level 2 at 260 C with one year of floor life |
| Temperature | minus 40 to 125 C operating, with the current limit specified at both 25 C and 125 C because it moves with temperature |
| Marking | U28881 on the body |
| Document | SLUSC36B, November 2015, revised January 2016 |
| Status | Active and in production, with no end of life notice on the current addendum |
Electrical parameters that decide the application
| Switch | an integrated 700 V MOSFET with 14 Ohm of on resistance at 25 C, rising to 24 Ohm at 125 C junction, which is the number that decides the conduction loss rather than the headline current |
| Output current | 225 mA in continuous conduction and 150 mA in discontinuous conduction, both for a non-isolated buck from a rectified mains rail |
| Bias | a 5 V regulator fed from the drain through an internal high voltage current source, so the part starts and runs from the rectified mains with no auxiliary winding |
| VDD thresholds | turn on at 4.5 V minimum, 5.0 V typical and 5.5 V maximum, turn off near 3.9 V, with roughly 0.35 V of hysteresis, so the external capacitor on the VDD pin is the only energy store the part has |
| Feedback threshold | 1.25 V on the FB pin, which is the reference the output divider is set against |
| Current limit | 330 mA minimum at minus 40 C and 440 mA typical at 25 C, which is why the output current rating is 225 mA rather than the limit itself |
| Switching | no clock and no fixed frequency: the switch on time is set by the feedback loop and the off time by a minimum that follows every on time, with a maximum switching frequency around 62 kHz typical |
| Soft start | the first off time is set above 100 us and steps down cycle by cycle to the minimum, which limits the inrush into the output capacitor |
| Quiescent current | under 100 uA with no load, which is the figure that lets a product meet a standby power target without a second controller |
| Protection | cycle by cycle current limit, overload and output short protection, thermal shutdown with hysteresis, and an undervoltage lockout on the VDD pin |
| Thermal | 134.4 C per W junction to ambient in the seven pin body, with 42.6 C per W junction to case, so the copper under the drain and ground pins is part of the thermal solution |
| Derating | output current falls with ambient, and the vendor gives a derating curve for continuous conduction at about 30 kHz with 10 uJ of switching loss |
Topologies and the parts that fit them
| Buck from a rectified mains | the topology the part was built for, with the inductor on the low side and the feedback taken through a level shift |
| Buck-boost | used when the output has to sit above or below the input, which a mains product often needs for a negative rail |
| Flyback | possible for a low power isolated bias supply, at the cost of an auxiliary winding for the output and a snubber for the leakage |
| Against a controller with an external FET | one body, 14 Ohm of switch and no gate resistor, at the cost of a fixed switch and a maximum current that cannot be raised |
| Against UCC28880 | the same family with a lower current capability, which is the part for a 100 mA housekeeping rail rather than a 225 mA one |
| Against a buck converter with a 100 V FET | the 700 V rating is the whole point, because the rectified mains rail reaches 375 V and a low voltage part cannot start from it without a separate bias supply |
Points to check before this part goes on a BOM
The self-biased start-up is what makes a seven pin part possible. The internal current source connects the drain to the VDD regulator and charges the external capacitor until the part turns on at about 5 V, after which the part runs from the same capacitor and the same source. That removes the start-up resistor chain that normally dissipates a watt at 375 V, which is why the standby power is low enough to matter. The price is that the VDD capacitor is the only store: it has to hold the part up through the switching cycle, and a capacitor that is too small shows up as a converter that starts, runs for a few milliseconds and restarts.
The current limit sets the output current, and the temperature coefficient has to be read before a rating is quoted. 440 mA typical at 25 C against 330 mA minimum at minus 40 C is a 25 per cent spread, and the 225 mA output rating sits below the cold minimum so that a production build at any temperature stays inside the limit. A board that is asked for 300 mA at 5 V and told the limit is 440 mA will work on a bench at room temperature and drop out of regulation in a cold chamber, and the failure looks like a soft start problem rather than a current limit problem.
There is no clock, which is the feature that confuses anyone who has used a fixed frequency converter. The switch turns on when the feedback voltage says the output is low, and turns off when the current limit trips or the on time ends. The off time follows a minimum and stretches as the load falls, so the switching frequency at full load is set by the inductor and the input voltage, and at no load it falls to a few kilohertz. That is what makes the quiescent current figure meaningful, and it is also why an emissions measurement has to be taken at full load, because the frequency at light load is not the one that produces the worst harmonic.
The 14 Ohm switch at 25 C and 24 Ohm at 125 C is the reason the output current is temperature limited. At 225 mA the conduction loss is 0.7 W at 25 C and 1.2 W at 125 C, and in a 134.4 C per W body that is 94 C and 161 C of rise. The second number is above the junction limit, which is why the vendor publishes a derating curve rather than a single current figure. A mains product that puts this converter inside a sealed enclosure and asks for the full 225 mA at 60 C ambient will find the part thermally limited long before the current limit is reached.
Protection during a shorted output is cycle by cycle rather than latched. The current limit trips on every cycle, the off time stretches, and the average current falls to a value the switch can survive, so a short on the output produces a hot part and a low output rather than a dead part. That behaviour is deliberate, and it is also the reason a short circuit test has to be run with a thermocouple on the package rather than with a current probe: the part survives the short and the package temperature is what decides whether the product passes.
What 225 mA at 5 V buys and what it does not
225 mA at 5 V is 1.1 W, which is enough for the housekeeping rail of a product whose main converter needs a bias supply, a relay driver, a display backlight at low brightness, or a microcontroller with a radio. It is not enough for a motor, a heater or a second stage converter that has to start into a load. The vendor also quotes 150 mA in discontinuous conduction, and the difference is the inductor: a larger inductor holds the current continuous at a lower load, which raises the usable output at the cost of size.
The input side is where the part is easier to use than expected. The rectified mains rail can reach 375 V at the high line and the drain is rated to 700 V, so no snubber is needed for the switch itself. What does need attention is the inductor current at the moment of turn off, because the drain sees the rail plus the inductor's flyback voltage, and an inductor with too much leakage pushes the drain above 700 V on the first edge. The rating is generous and it is not infinite.
Reading the standby current against a real product
Under 100 uA of quiescent current is a device figure, and the no-load input power of a product is a system figure. The converter contributes its own quiescent current plus the switching loss at light load, and the rest of the board contributes its own standby draw. A product that quotes 30 mW of no-load input power at 230 V is quoting about 130 uA at the mains, which leaves the converter very little room and is the reason the feedback divider has to be a high value and the output capacitor has to be small.
The measurement is also easy to get wrong. A no-load input power measurement on a mains product has to average over several seconds, because the converter's off time at light load is long and a short measurement window catches a burst rather than the average. The same trap applies to the switching frequency: an emissions scan at no load shows a different spectrum from one at full load, and the scan that matters for a limit is the one at the load the standard specifies.
Where this order code fits
This is the housekeeping and bias supply inside a mains product: a smart meter, a lighting driver, a small appliance, an industrial sensor or a relay board, wherever a 5 V rail has to start from the rectified mains and stay quiet when the product is idle Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the BOM Shortage Recovery page.
Questions buyers ask
Does it need an auxiliary winding to keep running? No. The internal current source feeds the VDD regulator from the drain, so the part starts and runs from the rectified rail. The VDD capacitor is the only energy store.
What is the maximum output current? 225 mA in continuous conduction and 150 mA in discontinuous conduction, both below the 330 mA cold current limit so that the part stays in regulation across temperature.
What sets the switching frequency? Nothing external. The on time is set by the feedback loop and the off time follows a minimum, so the part switches at about 62 kHz at full load and much slower at light load.
Is it isolated? No. The topology is a non-isolated buck or buck-boost. An isolated output needs a flyback with a transformer and an auxiliary winding.
Can it run from a 48 V rail as well as from the mains? Yes. The input range is set by the 700 V drain rating and the minimum start-up voltage, so a low voltage rail works as well as a rectified mains rail, which is why telecom and industrial products use it too.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Component Lead Time Solutions page sets out the checks that keep a substitute from failing on the bench.