UCC28880DR
Product Specifications
UCC28880DR
Texas Instruments — Power Management & Signal Chain
Product Overview
The UCC28880DR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
UCC28880DR: a 700 V switch and its controller in one body
UCC28880DR is an off line converter that puts a 700 V power MOSFET, the controller, a high voltage start up current source and the protection block into a single seven pin small outline body on a 2500 piece reel. The device is built for the low power end of the mains, supplies that deliver up to 100 mA in continuous conduction or 70 mA in discontinuous conduction from a rectified 230 V rail.
SLUSC05D, revised May 2016, is the document behind the string. The property that separates this part from a conventional off line switcher is that it needs no bias winding and no start up resistor chain: the device draws its own supply from the drain during start up and during operation, which removes the two components that usually fail first in a mains supply.
The ordering table prints both the tube and the reel rows as not recommended for new designs, which is a status a buyer has to read carefully before a new board is released against this string. What follows is what the integrated switch does, the topologies it supports, the thermal ceiling in a seven pin body, and how to read that status.
What sits inside the package
The drain is rated to 700 V, which covers a rectified 230 V mains with the usual margin and also covers a 120 V mains with a wide swing. The high voltage current source charges the VDD capacitor at start up and then keeps it topped up from the drain, so the device is self biased and the only external supply component is the VDD capacitor itself. Quiescent current is printed below 100 microamps, which is what makes a standby budget of a few tens of milliwatts possible without a separate housekeeping supply.
| Orderable code | UCC28880DR |
| Body | SOIC, 7 pins, 5.00 mm by 6.20 mm |
| Carrier | 2500 pieces on a large reel |
| Tube row | UCC28880D, 75 pieces per tube |
| Drain to source rating | 700 V |
| Output current, continuous conduction | up to 100 mA |
| Output current, discontinuous conduction | up to 70 mA |
| Device quiescent current | below 100 microamps |
| Topologies supported | buck, buck boost, flyback |
| Start up | internal high voltage current source, no bias winding |
| Soft start | internal, limits stress on the power stage at turn on |
| Protection | current limit, overload, output short circuit, thermal shutdown |
| Operating junction temperature | minus 40 to 125 degrees |
| Moisture rating | level 2, 260 degrees for one year floor life |
| Part marking | U28880 |
| Lifecycle status in the addendum | not recommended for new designs on both the tube and the reel row |
The three topologies and where each fits
The buck connection is the one used for a low side supply that has to sit at the mains potential, for example a TRIAC driver in a wall switch or a relay coil supply in a thermostat. The output is referenced to the switching node rather than to neutral, so the load has to tolerate that, and in exchange the circuit needs one inductor, one diode and two capacitors.
The buck boost connection gives an output that can sit above or below the input and is used where the mains range is wide and the load is a small constant current, for example an LED string in a lamp that has to work from 90 V to 264 V. The flyback connection is the one to choose where the output has to be isolated or where the output current is above what a buck can deliver at the low duty cycle that a 230 V input forces.
In all three the switching frequency is not a knob on this part. The device runs at a frequency set by the load and the inductor, in a valley current mode, and that is deliberate for a low cost supply: it removes the oscillator components and it keeps efficiency up at light load by dropping the frequency rather than by skipping pulses. The cost is that the inductor has to be chosen for the light load end as well as for the full load end, because an inductor sized only for 100 mA will run in discontinuous mode at 10 mA and the frequency will rise.
Thermal behaviour in a seven pin body
The body has no thermal pad, so the heat leaves through the seven leads and the copper around them. At 12 V and 100 mA the output is 1.2 W, and with an efficiency of about 75 percent on a buck from 300 V the dissipation is around 0.4 W, which the leads carry at roughly 100 degrees per watt junction to ambient with a modest copper area. That puts the junction about 40 degrees above ambient, which leaves room in a 60 degree enclosure.
The case that does not work is a wide input range at full load with a high ambient. The current limit is fixed internally and the device will enter thermal shutdown rather than fold back, so a supply that is marginal will restart in bursts and the output will show a low frequency ripple. That ripple is the signature of a thermal problem and not of a control loop problem, and it is worth recognising before a board is reworked.
Reading the lifecycle status honestly
The addendum prints both rows as not recommended for new designs. That is the vendor's status word and it does not mean the part is unavailable: it means the vendor does not want new programmes to start on it. For a buyer the practical consequences are three: the part is still orderable from stock and from the channel, the datasheet will not be revised for new features, and a long programme should plan an alternative before the last time buy window opens.
Where a board is already in production the part is a legitimate choice and the work is to secure supply. Where a board is being released now, the same function has to be checked against the current generation of off line switchers, which usually means a part with an integrated inductor or a higher switching frequency and a smaller body.
The obsolete part cross reference hub is where we start when a status like this appears on a bill of materials, and the last time buy and LTB planning page covers the arithmetic of a bridge buy for a programme that runs past the notice date.
Questions that come with this string
Does the device need a bias winding? No. The internal high voltage current source feeds VDD from the drain during start up and during operation, which is the property the part is bought for. A bias winding can still be added on a flyback to cut the internal dissipation, and on a 12 V output that is worth doing above about 50 mA.
What sets the output current limit? The internal current limit on the drain, not an external resistor. That is why the output current falls as the input voltage rises on a buck connection, because the same peak current delivers less average current at a higher duty cycle limit.
Can the part run from a 400 V DC bus? The drain is rated to 700 V and a rectified 230 V mains peaks at 325 V, so the DC bus case fits with margin. A 400 V bus with a 100 V transient reaches 500 V, which is still inside the rating, and the leakage inductance spike on the drain is what has to be clamped.
How is the part checked on a line? A functional test at one input voltage with the rated load, plus a no load check of the standby input power, catches a wrong inductor and a wrong VDD capacitor. The thermal behaviour has to be checked in the chamber, because a part that passes a two second functional test can still enter thermal shutdown after three minutes. The incoming inspection plan covers the reel level checks that come before that.