Product Specifications

UCC28704DBVR-1 — Power Management & Signal Chain | Superb Automation

UCC28704DBVR-1

Texas Instruments — Power Management & Signal Chain

Product Overview

The UCC28704DBVR-1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

UCC28704DBVR-1: a primary side regulated flyback controller for off-line adapters in the 5 W to 15 W class, with 85 kHz maximum switching, 300 mV of cable compensation and no optocoupler, in the six pin SOT-23 on a 3000 piece reel

UCC28704DBVR-1 is a constant voltage and constant current controller that reads the output through the auxiliary winding of the transformer, so the secondary side of the converter carries a rectifier and a capacitor and nothing that has to be adjusted at test in a SOT-23 body of 6 pins. The DBV body measures 2.90 mm by 1.60 mm, and the -1 that closes the ordering string is part of the vendor part number rather than a different die or a different pinout.

Order code and package

Catalogue stringUCC28704DBVR-1, where DBV is the six pin SOT-23, R is the large tape and reel and the trailing -1 belongs to the ordering string exactly as the vendor prints it
BodySOT-23, six pins, 2.90 mm by 1.60 mm of moulding, which is the smallest body this family uses
Reel3000 pieces on a large tape and reel, and 250 pieces on a small reel when the same die is ordered as UCC28704DBVT-1
Addendum rowsthe plain row, the .A row and the .B row all read Active with 3000 pieces on a large reel, so the revision letter does not change the packing
Finish and moistureNIPDAU plating, moisture level 1 at 260 C with no floor life limit, which is what an unsealed bag on an assembly line wants
Temperatureminus 40 to 125 C on the published rows, with the electrical table specified over the same ambient range
Marking7041 on the body, which is short enough that the date code sits on the second line
DocumentSLUSCA8A, February 2016, revised February 2016
StatusActive and in production, not a last time buy and not a part flagged for new builds

Electrical parameters that decide the application

Bias range8.5 V to 35 V operating on VDD, with the turn-on threshold at 21 V typical, 17.5 V minimum and 23 V maximum, and the turn-off threshold at 7.7 V typical
Bias current2.5 uA typical in the start state, 70 uA typical in the wait state, 2.3 mA in the run state and 2.2 mA in the fault state, which is what makes a resistor from the rectified mains a usable start path
Current sense, maximum750 mV at 3.70 V on the VS pin, with a 720 mV minimum and 784 mV maximum window
Current sense, minimum187.5 mV at 4.35 V on the VS pin, and the ratio between the two thresholds is 3.55, which is the modulation range the controller has to work with
Constant current level2.48 V at the CS pin, window 2.41 V to 2.55 V, measured with the output pulled to 3.0 V for the test
VS regulating level4.06 V at no load and 25 C, window 4.02 V to 4.10 V, with a deliberate 1 mV per C drift that compensates the output rectifier over temperature
VS negative clamp250 mV at 300 uA pulled out of the pin, which is what lets the auxiliary winding swing below ground without a clamp diode
Over-voltage1.15 times the regulating level, window 1.13 to 1.18, so a 5 V output is protected at about 5.75 V
Switching frequency85 kHz maximum, window 78 to 94 kHz, and 1.03 kHz minimum, window 0.88 to 1.18 kHz
Gate drive32 mA source at 5 V on the gate, 12 Ohm pull-down at 35 V of bias, and a clamp at 10.6 V typical when the VS pin reads 3.7 V
Timing255 ns of leading edge blanking, 2.39 us of zero crossing timeout and 120 ms of blanking before the constant current under-voltage protection latches
Cable compensation300 mV at 5 V of output and full load, applied as a rising offset so a long cable does not drop the voltage at the plug

What the six pins do

NTC/SU, pin 1a remote temperature input that takes an NTC resistor to ground, with a maximum of 100 pF of filter capacitance and left floating when unused
VDD, pin 2bias input, charged by a resistor or an external depletion mode FET at start, then fed by the auxiliary winding once the converter runs
DRV, pin 3the gate output, clamped so a 35 V bias rail cannot put more than about 13 V on the gate, with a 205 kOhm pull-down while the part sits in the start state
CS, pin 4current sense input across a ground referenced resistor, with a series resistor for line compensation and no filter capacitor, because a capacitor here distorts the waveform the controller measures
GND, pin 5the return for the control and the gate drive loop
VS, pin 6the auxiliary winding sense input, which sets the regulation point, the run and stop thresholds of the mains, the over-voltage comparison and the demagnetisation timing

Points to check before this part goes on a BOM

Primary side regulation removes the optocoupler and moves the accuracy problem into the transformer. The controller samples the auxiliary winding during the demagnetisation interval, so the output voltage it sees is the winding voltage scaled by the turns ratio, minus the rectifier drop and minus the resistive drop of the secondary. A transformer with 5 per cent coupling tolerance and a winding that sits on the wrong side of the bobbin will produce a supply that regulates at 4.75 V on one build and 5.25 V on the next, and no amount of trimming at the controller fixes that. What the vendor guarantees is 5 per cent of output voltage and 5 per cent of output current with the transformer built to the recommended winding order, and the 5 per cent is a system number rather than a controller number.

The constant current loop is what makes this part useful for a charger rather than only for a bias supply. The current sense threshold moves with the VS pin voltage, from 750 mV when the output is at the bottom of its range to 187.5 mV when it is at the top, and the ratio of 3.55 between the two ends is the range over which the controller can hold a constant current while the output voltage collapses into a short. A board that needs a precise current limit at one point in the range cannot use this scheme, because the limit is a function of the output voltage by construction.

The constant current under-voltage protection is the part of the loop that protects the connector. A soft short on a USB cable looks like a low resistance that the current loop can feed indefinitely, and the heat ends up in the plug rather than in the converter. The controller watches the output voltage while the current loop is active, and when the output stays below the 3.0 V test point for longer than 120 ms of blanking it stops switching, waits, and restarts. The 120 ms is long enough that a legitimate load step does not trip it and short enough that a connector does not have time to discolour.

Cable compensation of 300 mV at 5 V and full load is a fixed offset rather than a function of output voltage, which matters when the same controller is used for a 5 V, 9 V or 12 V output. The compensation is roughly a 6 per cent lift at 5 V and 2.5 per cent at 12 V, so a board that changes the output voltage without revisiting the sense divider will over-compensate the low voltage rail or under-compensate the high one. A USB Type-C adapter that switches between 5 V and 20 V has to accept that the cable drop is corrected well at the bottom of the range and only partly at the top, or move the correction to the secondary side.

The start-up path is the other place where a small part number carries a real constraint. The controller draws 2.5 uA in the start state and 70 uA in the wait state, so a 1 MOhm resistor from a 400 V bulk rail delivers about 379 uA into VDD and charges a 10 uF capacitor to the 21 V turn-on point in roughly 0.6 s. At a 90 V mains the same resistor delivers about 99 uA, which still covers the wait current with margin. A board that stacks two resistors to share the voltage has to redo that arithmetic, because the leakage of the divider and the tolerance of the resistors decide whether the supply starts at low line in a cold room.

Eighty-five kHz of maximum switching is a compromise between transformer size and switching loss, and the part runs in discontinuous conduction with valley switching to keep the turn-on loss down. The valley switching also moves the effective frequency with load and line, which is why the minimum frequency of about 1 kHz appears in the table: at no load the controller stretches the off time until it is barely switching, and the audible band is crossed slowly enough that a transformer without varnish can sing. A board that has to be quiet at no load needs the transformer potted or the minimum load held above a few tens of milliamps.

Reading the -1 suffix against a purchase order

The ordering string on this page ends in -1, and the vendor addendum prints three rows for it, UCC28704DBVR-1, UCC28704DBVR-1.A and UCC28704DBVR-1.B, all Active on 3000 piece reels. The same addendum also prints UCC28704DBVT-1 on a 250 piece small reel. What it does not print is UCC28704DBVR without the -1, so a purchase order that drops the suffix is asking for a string the vendor does not list, and a distributor that accepts it may ship a different revision or hold the line while the part number is clarified.

The suffix is therefore a sourcing fact rather than an electrical one, and it belongs on the purchase order, on the incoming inspection sheet and in the BOM note. A buyer who compares quotations from two suppliers should compare the full string, because a quotation for the unsuffixed part at a lower price is not a quotation for this device.

What 300 mV of cable compensation means in practice

A 1 m USB cable with 0.3 Ohm per conductor drops 0.6 V at 2 A, which is exactly the kind of loss the compensation is meant to hide from the load. The controller lifts its regulation point as the current rises, and the lift is scaled so that at 5 V and full load the voltage at the plug is close to 5 V again. The number in the data sheet is a target for a reference cable, not a guarantee for the cable a customer uses, and a 2 m cable with thinner conductors still drops more than the loop can correct.

The practical consequence is that a charger built around this part should be tested at the end of the cable the product ships with, not at the output capacitor. A test at the capacitor passes, and the same unit at the plug fails the 4.75 V floor of the USB specification.

Where this order code fits

USB Type-C and fixed voltage adapters for phones and tablets, standby bias supplies in metering and building automation, and low power industrial or medical supplies that have to meet DoE Level VI and CoC Tier 2 without an optocoupler Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Component Lead Time Solutions page.

Questions buyers ask

Does it need an optocoupler? No. The output is read through the auxiliary winding, and the secondary side carries a rectifier and a capacitor.

What decides the output accuracy? The transformer coupling and the VS divider. The controller holds 5 per cent of voltage and current with the transformer built as the vendor describes.

Can it drive a synchronous rectifier? Yes. The gate drive is clamped and the timing supports a secondary side synchronous rectifier controller for outputs of 2 A and above.

What happens in a short circuit? The current loop takes over, the output voltage collapses, and the constant current under-voltage protection stops switching after 120 ms of blanking, then restarts.

Is the -1 part of the part number? Yes. The vendor addendum lists the string with the -1 and does not list it without, so it has to be carried on the purchase order.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the How to Verify a Drop in Replacement page sets out the checks that keep a substitute from failing on the bench.