UCC28700DBVR
Product Specifications
UCC28700DBVR
Texas Instruments — Power Management & Signal Chain
Product Overview
The UCC28700DBVR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
UCC28700DBVR: Primary-side regulated flyback controller for CV and CC outputs
UCC28700DBVR is a constant-voltage, constant-current flyback controller that needs no optocoupler in a SOT-23 body of 6 pins. It regulates output voltage and current from the primary side using the auxiliary winding, holds plus or minus 5 percent on both, switches at up to 130 kHz with valley switching, and keeps no-load input power below 30 mW.
Order code and package
| Ordering string | UCC28700DBVR, DBV package, tape and reel |
| Package | 6-pin SOT-23, the smallest body in the family |
| Family variants | UCC28700, 01, 02 and 03 differ in protection and temperature-sense options |
| Driving a switch | Clamped gate-drive output for an external high-voltage MOSFET |
| Isolation | The transformer provides the barrier; the controller never crosses it |
Electrical parameters that decide the application
| Regulation | Plus or minus 5 percent on voltage and on current |
| Maximum frequency | 130 kHz, always under control of the peak current |
| No-load power | Below 30 mW at nominal line |
| Mode | Discontinuous conduction with valley switching |
| Bias range | Wide VDD window, so a small bias capacitor is enough |
| EMI | Frequency jitter spreads the switching spectrum |
| Protections | Overvoltage, low-line and current limit |
Points to check before this part goes on a BOM
Removing the optocoupler removes the component that ages. An optocoupler's current transfer ratio falls with temperature and time, and a charger that has to hold 5 percent for ten years is exactly where that drift shows up. Primary-side regulation reads the auxiliary winding instead, so the accuracy budget moves from the optocoupler to the transformer coupling and the current-sense resistor, both of which are stable but neither of which is exact.
Thirty milliwatt of no-load input power on a 5 W charger is 0.6 percent of full load, and it is the number that decides whether a product passes a standby requirement. It is reached by skipping cycles and by dropping into low-frequency operation, not by a linear bias supply, so the VDD capacitor has to hold the controller up between switching bursts. A bias capacitor that is too small turns the standby saving into a restart loop.
The 130 kHz ceiling is a maximum, not an operating point. In discontinuous conduction with valley switching the frequency falls as the load falls, and the transformer has to be specified for the minimum frequency at full load, where the flux swing is largest. A transformer copied from a fixed-frequency flyback of the same power will saturate in this circuit, because the on time at low line is longer than the copy expects.
Valley switching turns the drain ringing into a turn-on at the bottom of the valley, which cuts the turn-on loss and the radiated noise at the same time. The effect depends on the leakage inductance and the drain capacitance, so a different MOSFET or a different snubber moves the valley and can put the turn-on back on a peak. The controller follows the valley; it cannot create one where the resonance does not exist.
Frequency jitter is the cheap route to an EMI pass. Spreading the switching energy over a band lowers the peak of each harmonic, which is what a quasi-peak detector measures, and it often removes a filter stage. It does not reduce the total energy, so a board that fails by a wide margin still fails; jitter buys a few decibels, not immunity.
The six-pin body carries the bias, gate drive, current sense and the auxiliary voltage feedback, which leaves no room for a second control loop. Everything about the output current has to be expressed through the primary peak current and the transformer turns ratio, so the current-sense resistor is the accuracy part: a 1 percent resistor is the difference between a charger that holds 5 percent over temperature and one that does not.
The current-sense resistor and the auxiliary winding are the two parts that set regulation accuracy, and both are specified outside the controller. A 1 percent sense resistor contributes 1 percent directly, and the auxiliary winding's coupling to the secondary adds a term that varies with winding order and with the leakage inductance of the build. Two transformers that measure the same on an inductance bridge can give different load regulation in the same circuit, which is why a primary-side circuit is qualified with the actual transformer rather than with a datasheet copy.
Where this order code fits
The fit is a 5 W to 30 W AC input charger or adapter for a phone, a tablet, a router or a metering product, where the output is a voltage and current characteristic and the isolation barrier is in the transformer. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the BOM Shortage Recovery page.
Questions buyers ask
Do I still need a secondary-side reference with primary-side regulation? No. The auxiliary winding supplies the voltage information and the controller closes both loops from the primary. A secondary reference or an optocoupler in the same circuit defeats the purpose and adds drift the controller cannot correct.
Why is my no-load power higher than 30 mW? Usually the bias winding, the snubber, or a bleeder on the output. The controller's own consumption is microamps; the loss is in the parts around it, and a snubber that was sized for a different leakage inductance burns most of it.
Can this controller drive a 650 V MOSFET directly? The gate drive output is clamped and intended for a high-voltage MOSFET gate. The gate charge and the drive current set the switching loss, and at 130 kHz a large die with high gate charge turns the drive into a heat source, so the switch is chosen together with the frequency.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Component Lead Time Solutions page sets out the checks that keep a substitute from failing on the bench.