Contact Us

UCC28084DR

Brand: Texas Instruments
Texas Instruments UCC28084DR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

UCC28084DR — Power Management & Signal Chain | Superb Automation

UCC28084DR

Texas Instruments — Power Management & Signal Chain

Product Overview

The UCC28084DR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

UCC28084DR: current mode push pull controller with 50 kHz to 1 MHz oscillator and 110 ns dead time

UCC28084DR is a BiCMOS current mode controller for push pull and half bridge converters, with two alternating outputs that are never on together and a dead time of 110 ns between them in a SOIC body of 8 pins. The UCC28084 is the member of the UCC38083 family with internal soft start. It runs from a single supply, starts on 120 uA and draws 1.5 mA once running, and its oscillator is set by one external component from 50 kHz to 1 MHz. The two totem pole outputs alternate and are limited to less than 50 percent duty each, with 1 A sink and 0.5 A source capability, and the dead time between them is 110 ns typical. Current mode control with programmable slope compensation and cycle by cycle limiting is built in.

Order code and package

Order codeUCC28084DR
Functioncurrent mode PWM controller, push pull or half bridge
Outputstwo alternating totem pole drivers, each below 50 percent duty
Oscillator range50 kHz to 1 MHz, set by one external component
Start-up current120 uA typical
Run current1.5 mA typical
Output drive1 A sink, 0.5 A source
Soft startinternal, 3.5 ms typical on the UCC38083 and UCC38084
Package8 pin SOIC, D body
Pin count8
DocumentSLUS488E, September 2002, revised July 2009

Electrical parameters that decide the application

Dead time between outputs110 ns typical
Maximum duty per outputless than 50 percent
Slope compensationprogrammable through the ISET pin, ISLOPE about 5 times ISET
Oscillator ramp amplitude1.5 V at the ISET pin
ISET peak current30 uA at full duty
Control divider ratio0.45 of the output sense
Current limitcycle by cycle, from the CS pin
Soft start interval3.5 ms typical, internal on the UCC38083 and UCC38084
UVLOwith hysteresis, thresholds set by the family grade
Junction rangeindustrial, -40 C to 85 C ambient for the DR order code

Points to check before this part goes on a BOM

Two outputs that can never overlap is the safety property of this family. Each output is held below 50 percent duty and the gap between them is 110 ns typical, so a push pull transformer cannot be shorted across its primary by both switches at once even if the control loop demands full duty. That is a fixed hardware limit rather than a software setting, and it is why the part is chosen where a firmware fault must not destroy a bridge.

The 120 uA start-up current is the specification that makes a high voltage start resistor practical. From a 400 V bus, a 1 Mohm resistor supplies about 400 uA, which leaves room to charge the supply capacitor and to run the controller at its 1.5 mA operating current only after the auxiliary winding takes over. A controller that needs 1 mA before it starts would force a much smaller resistor and a permanent dissipation of hundreds of milliwatts.

Slope compensation is programmable, and the relationship published in the datasheet is that the slope current is about five times the current set on the ISET pin, added to the current sense signal at the CS pin. That matters in a current mode converter because without slope compensation the loop is unstable above 50 percent duty, and with too much the current loop loses its response to a real overload. The one component on ISET sets both the oscillator and the slope.

The internal soft start of 3.5 ms is what keeps the output from overshooting at power up and keeps the transformer from saturating while the output capacitors charge. On the members of the family without internal soft start the same job needs an external capacitor and a current source, which is the reason this order code exists. Three and a half milliseconds is fixed by the die, so a supply with a very large output bank may need additional ramp control outside the controller.

The control divider ratio of 0.45 means the error amplifier sees 45 percent of the sensed output, which sets the feedback divider values and the loop gain. A divider carried over from a 2.5 V reference controller will not produce the same output voltage. The reference is internally trimmed, and the datasheet revision history shows the ordering information and the electrical table were reissued over the years, so the revision on the document attached to the offer has to match the revision the board was qualified against.

Drive capability of 1 A sink and 0.5 A source is modest by modern standards and limits the switch size. A MOSFET with 60 nC of gate charge at 200 kHz needs about 12 mA of average current, which is well inside the part, but the peak current during the Miller plateau is what sets the switching time. Above roughly 100 nC of gate charge the rise time stretches and the switching loss moves from the driver into the MOSFET, so a larger switch usually needs a buffer stage.

This is an older BiCMOS controller, first released in 2002 and last revised in 2009, and it is still offered. A board that has been running this part for years should keep the exact order code in the approved vendor list rather than accepting a nearby family member, because the internal soft start and the UVLO thresholds differ between the members of the family. Second sourcing starts with the family suffix, not with the pin count.

Where this order code fits

This order code suits push pull, half bridge and low cost forward converters in telecom dc to dc modules, point of load bricks and offline supplies up to a few hundred watts, where two switches have to be driven alternately and the transformer has to be kept out of saturation. The 120 uA start-up current is what makes it usable with a high value start resistor from a high voltage bus. Boards comparing it with a neighbouring part start from our Power Management Cross Reference page, and boards replacing a part that has gone end of life start from the Obsolete Part Cross Reference Hub page.

Questions buyers ask

Can the two outputs be paralleled for more drive? No. They alternate by construction, and the 50 percent duty limit with 110 ns dead time is what protects a push pull primary.

What sets the switching frequency? One external component on the oscillator pin, from 50 kHz to 1 MHz. The same pin current also sets the slope compensation.

Does it include soft start? Yes, the UCC38083 and UCC38084 have internal soft start with a 3.5 ms typical interval. Other family members need an external capacitor.

SUPERB holds this order code and states date codes, packing and country of origin on the offer, and the Component Lead Time Solutions page lists the fields to compare before a controller position is filled from a second line.