UCC28070APWR
Product Specifications
UCC28070APWR
Texas Instruments — Power Management & Signal Chain
Product Overview
The UCC28070APWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
UCC28070APWR: Two-Phase Interleaved Continuous Conduction Mode PFC Controller
UCC28070APWR is an interleaved two phase power factor correction controller for continuous conduction mode in a 20-pin TSSOP body of 20 pins. It drives two phases 180 degrees apart from one current sense winding, which halves the ripple the input capacitor sees and lets a 3 kW front end use two small inductors instead of one large one.
Order code and package
| Ordering string | UCC28070APWR, TSSOP-20 (PW), 6.5 mm by 4.4 mm |
| Sibling order code | UCC28070DW, SOIC-20 (DW), 12.8 mm by 7.5 mm |
| Phases | two, interleaved, 179 to 181 degrees between GDA and GDB |
| Control | average current mode, continuous conduction, frequency set by RT |
| Supply | 12 V nominal, shunt clamp at 23 V to 27 V |
| Reference | 6 V buffered, 5.82 V to 6.18 V |
Electrical parameters that decide the application
| VCC shunt voltage | 23 V min, 25 V typ, 27 V max at 10 mA |
| UVLO turn on | 9.8 V to 10.6 V rising |
| Reference enable | 7.5 V to 8.5 V on a rising VCC |
| Reference accuracy | 6 V plus or minus 3 percent |
| Reference load rejection | 12 mV at 2 mA |
| Supply current | 4 mA to 6 mA enabled at 9 V |
| Phase shift | 180 degrees plus or minus 1 degree |
| Timing pin voltage | 2.91 V to 3.09 V on DMAX, RT and RDMX |
| PFC enable | 0.65 V to 0.85 V on VSENSE, 0.15 V hysteresis |
| Current sense | CSx pins against the internal limit, both phases summed |
Points to check before this part goes on a BOM
The 6 V reference at plus or minus 3 percent is 180 mV, and a divider that makes 390 V from 6 V scales that to 11.7 V of output uncertainty. Two boards built from different lots of resistor and different controllers can therefore sit 11.7 V apart at the same nominal setting, which is why the output capacitor has to absorb the spread and why trimming one board tells you about one board.
One degree of phase error at 100 kHz is 27.8 ns, and the part is specified within one degree, so the two phases can be 55.6 ns apart at the extremes. Interleaving cancels input ripple only while the duty cycles match, so the cancellation this part promises is limited by the inductor tolerance and the current loop, both larger than the 55.6 ns.
The shunt clamps at 25 V, so a 12 V housekeeping rail never reaches it. It exists for a gate drive fed from 15 V or 18 V through a dropper, and in that case the dropper carries the difference at 6 mA and dissipates 18 mW to 36 mW, which is trivial but has to be there or the clamp conducts instead.
The PFC enable sits on VSENSE, the same pin as the feedback divider, with a window of 0.65 V to 0.85 V and 0.15 V of hysteresis. That means the lower leg of the divider has to be chosen so the pin crosses the window on a 390 V output, and the enable point moves with the divider as the output setting changes.
DMAX, RT and RDMX are all regulated against 3 V plus or minus 3 percent, so the same timing resistor gives a switching frequency that varies 3 percent from part to part, and the inductor ripple follows the frequency. A 100 kHz setting is therefore 97 kHz to 103 kHz across production, which matters when the EMI filter is tuned to one number.
Average current mode needs the inductor current, and this controller takes it from a sense element on each phase and sums the two internally. Two phases with different sense gains split the current by gain rather than by resistance, so one phase carries more, heats more and reaches saturation first, which is why the two inductors have to be the same part and the two sense paths have to be trimmed together.
At the 25 V clamp and 6 mA the controller dissipates 150 mW, and the 20-pin TSSOP has a junction to ambient near 100 C/W without copper under it, so the part sits about 15 C above ambient before any gate charge is counted. Two 15 nC gates at 100 kHz add 36 mW; two 60 nC gates at the same rate add 144 mW, three times the housekeeping loss.
Where this order code fits
Server and telecom front ends, air conditioner inverters and industrial power supplies use this part where a 1 kW to 3 kW front end has to meet harmonic limits with a small input filter. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the One Stop BOM Sourcing page.
Questions buyers ask
Can one phase be used alone? The controller is built around two phases and the current loop sums both sense inputs, so running only one means leaving the second gate unconnected and the sense input at zero, which changes the loop gain and is not the intended use.
What sets the switching frequency? A resistor from RT to ground against the internal 3 V reference, with the same 3 percent tolerance, so the frequency is a resistor choice with a known spread.
Is a bias winding needed? Not if VCC is fed at 12 V from a housekeeping supply. The shunt clamp at 25 V is there for a dropper feed from a higher rail.
How is the peak current limited? Each phase has a sense input compared against the internal limit, and the two are summed for the average current loop, so a single phase can hit the limit while the total is below it.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Component Lead Time Solutions page sets out the checks that keep a substitute from failing on the bench.